GB 19489-2008Laboratories - General requirements for biosafety (English PDF)

实验室 生物安全通用要求

Open the GB 19489-2008 preview as PDF

Preview — first pages of GB 19489-2008 (full document: 36 pages)

This is a limited preview

Buy now to download the full PDF (36 pages)

Issued by

AQSIQ; SAC

Level / Type

National · Mandatory

Issue date

December 26, 2008

Implementation date

July 1, 2009

Scope

GB 19489-2008 is the English-translated version of 实验室 生物安全通用要求.

The foundation document of laboratory biosafety in China, and the one every other biosafety standard in the country refers back to. It sets the general requirements for the biosafety of laboratories: the risk assessment and risk control that everything else follows from, the classification of laboratories into biosafety levels 1 to 4, the design principles and basic requirements, the requirements for the facilities and equipment of each level in turn - BSL-1, BSL-2, BSL-3 and BSL-4, and then the animal biosafety laboratories - and, at greater length than any of them, the management requirements. It applies to the laboratories in which biological agents are handled and is the basis on which such a laboratory is designed, accredited and inspected. The half of the standard given over to management is what distinguishes it from a design code and is the reason it is written the way it is: containment is not a property of a building but of an organisation, and a BSL-3 laboratory whose documents are out of date, whose staff have not been trained or whose failures are not reported is not a BSL-3 laboratory whatever its ventilation drawings show. That clause therefore reads as a management system in the manner of the accreditation standards: organisation and management, management and personal responsibility, the safety management system documentation and its control, the safety plan and the safety inspection, the identification and control of nonconformities, corrective and preventive action, continual improvement, internal audit and management review, and then the operational chapters - personnel, materials, the management of laboratory activities, housekeeping, facilities and equipment, waste disposal, emergency preparedness, fire safety and accident reporting. Issued on 26 December 2008 and in force since 1 July 2009, it replaces GB 19489-2004. GB 27421-2015 extends it to mobile laboratories.

Document preview — GB 19489-2008

National Standard of the People's Republic of China

ICS
13.100
Classification
C 52
Replacing
GB 19489-2004

Issued by: General Administration of Quality Supervision, Inspection and Quarantine; Standardization Administration of the PRC

Contents

  • 1 Scope
  • 2 Terms and definitions
  • 3 Risk assessment and risk control
  • 6.1 BSL-1 laboratory
  • 6.2 BSL-2 laboratory
  • 6.3 BSL-3 laboratories
  • 6.4 BSL-4 laboratory
  • 7.1 Organization and Management
  • 7.2 Management responsibility
  • 7.3 Personal liability
  • 7.4 safety management system documents
  • 7.5 Document Control 15
  • 7.7 security check
  • 7.9 Corrective Action
  • 7.10 Preventive Measures
  • 7.11 Continuous Improvement
  • 7.12 Internal Audit
  • 7.15 Laboratory Materials Management
  • 7.18 laboratory facilities and equipment management
  • 7.22 Fire Safety
  • 20 Transport of hazardous materials
  • 29 References

Foreword

This standard is the first 3.1.10,6.3.1.5,6.3.10.4,6.3.10.5,

6.5.1.9 Article recommendatory, others are strong Compulsory provisions. This standard replaces GB 19489-2004 "General requirements for laboratory biosafety." This standard compared with GB 19489-2004, the main changes are as follows:

--- Criteria for the classification of the elements have been adjusted, a clear distinction between technical elements and management elements (2004 edition, Chapter 6 to Chapter 20, Excerpts of Chapter 5 to Chapter 7);

--- Remove the 2004 edition of some of the terminology and definitions (2004 version 2.2,2.3,

--- Revised 2004 edition of some of the terminology and definitions (2004 edition 2.1,2.4,2.6,2.7,2.9,2.10,2.12,2.13,

--- Adding new terms and definitions (Excerpts 2.2,2.8,2.9,2.11,2.12,2.14,2.17,

2.18 and 2.19) ;

--- Delete harm degree classification (Chapter 3 of the 2004 edition);

--- Revised and increased the risk assessment and risk control requirements (2004 edition, Chapter 4, Section 3 of this edition);

--- Revised the design principles of laboratory facilities and equipment, part of the requirements (2004 edition, Chapter 6, Section 7 and Section 9.3, this The first version of Chapter 5 and Chapter 6);

--- Added laboratory facilities automation system requirements (this version 6.3.8);

--- Increased its laboratory facilities in invertebrates operating requirements (this version 6.5.5);

--- Added management requirements (Excerpts 7.4,7.5,7.8,7.9,7.10,7.11,

--- Removed some and GB 19781-2005 "Medical Laboratory Safety requirements" duplicate content (2004 edition Chapter 3, , Chapter 13, Chapter 14, Chapter 15 and Chapter 17, Chapter 12);

1 Scope

The foundation document of laboratory biosafety in China, and the one every other biosafety standard in the country refers back to. It sets the general requirements for the biosafety of laboratories: the risk assessment and risk control that everything else follows from, the classification of laboratories into biosafety levels 1 to 4, the design principles and basic requirements, the requirements for the facilities and equipment of each level in turn - BSL-1, BSL-2, BSL-3 and BSL-4, and then the animal biosafety laboratories - and, at greater length than any of them, the management requirements. It applies to the laboratories in which biological agents are handled and is the basis on which such a laboratory is designed, accredited and inspected. The half of the standard given over to management is what distinguishes it from a design code and is the reason it is written the way it is: containment is not a property of a building but of an organisation, and a BSL-3 laboratory whose documents are out of date, whose staff have not been trained or whose failures are not reported is not a BSL-3 laboratory whatever its ventilation drawings show. That clause therefore reads as a management system in the manner of the accreditation standards: organisation and management, management and personal responsibility, the safety management system documentation and its control, the safety plan and the safety inspection, the identification and control of nonconformities, corrective and preventive action, continual improvement, internal audit and management review, and then the operational chapters - personnel, materials, the management of laboratory activities, housekeeping, facilities and equipment, waste disposal, emergency preparedness, fire safety and accident reporting. Issued on 26 December 2008 and in force since 1 July 2009, it replaces GB 19489-2004. GB 27421-2015 extends it to mobile laboratories.

This standard specifies the basic requirements for different levels of biosafety laboratory facilities, equipment and safety management. Chapter 5,

6.2 as well as biological safety requirement is based biosafety laboratories, if necessary, apply a higher level of protection Laboratory and animal biosafety laboratory. Infected animals for breeding and related laboratory activities, this standard provides for laboratory animal breeding facilities and environment of the basic begging. If desired,

6.4 for the appropriate level of protection of animal biosafety laboratory. This standard applies to biological factors involved in laboratory operations.

2 Terms and definitions

The following terms and definitions apply to this standard.

2.1 Suspended in a gaseous medium particle size is generally 0.001µm ~ 100µm tiny solid or liquid particles form relatively stable points Bulk system.

2.2 Resulting in death, unexpected illness, injury, damage and other losses.

2.3 With mechanical ventilation system, the overall sterilization conditions, chemical spray (when applicable) and the pressure can be monitored airlock, its doors have mutual Lock function can not be turned on.

2.4 Microorganisms and bioactive substances.

2.5 With air control and efficient air filtering device operation panel, which can effectively reduce harmful aerosols produced during the experiment operator And harm the environment.

2.6 Set in a closed chamber is the probability of contamination between different laboratory areas, if necessary, install a mechanical ventilation system, which has a door interlock function, It can not be turned on.

2.7 Especially the flow of pollution from small regional pollution probability of the probability of large areas controlled airflow.

2.8 It may result in death, injury or illness, property damage, environmental damage working conditions or a combination of these root causes or state.

2.9 Identify hazards exist and to determine the characteristics of the process.

2.10 Usually 0.3µm particle test substance under the conditions specified above 99.97% removal efficiency air filter.

2.11 Causes or could cause an accident.

2.12 Biological factors involved in the operation of the laboratory.

2.13 Laboratory biosafety conditions and the state of not less than the allowable level, to avoid laboratory staff, visitors, communities and the environment is not Acceptable damage, in line with relevant regulations, standards and other laboratory biosafety liability requirements.

3 Risk assessment and risk control

3.1 The laboratory shall establish and maintain a risk assessment and risk control procedures to ongoing hazard identification, risk assessment and implement the necessary control Control measures. Content Lab to consider include.

3.1.1 When laboratory activities involving pathogenic biological agents, biological laboratories should be a risk assessment. Risk assessment should consider (but not limited to, To) the following.

a) biological agents known or unknown characteristics of biological factors such as species, source, infectious, transmission, susceptibility to latency agent Amount - effect (response) relationship, pathogenicity (including acute and long-term effects), variability, stability in the environment, and other creatures And interactions, the relevant experimental data, epidemiology, prevention and treatment programs and other environments;

b) Where applicable, the laboratory itself or accidents have occurred related laboratory analysis;

c) routine laboratory activities and unconventional activities in the process of risk (limited to biological factors), including all the people into the workplace Members and staff may be involved (eg. contractor personnel) activities; Risks associated with

d) facilities, equipment and so on;

e) if applicable, the risks associated with experimental animals;

f) people related risks, such as physical condition, ability, may affect the working pressure;

g) accident, accident risks;

h) has been misused and the risk of malicious use;

i) the scope of the risk, nature and timing; Probability

j) risk assessment;

k) hazards and possible consequences of the analysis;

l) to determine the acceptable level of risk;

6.1 BSL-1 laboratory

6.1.1 Laboratory doors should be locked and windows, door locks and door opening direction shall be without prejudice to the person in the room to escape.

6.1.2 should be located washbasins, should be provided in the near laboratory exit.

6.1.3 In the laboratory should be located at the entrance cloakroom or hanging devices, personal clothing and lab coats can be placed separately.

6.1.4 Laboratory walls, ceilings and floors should be easy to clean, impervious, corrosion and chemical sterilization agent. Floors should be smooth, Non-slip, not carpeted.

6.1.5 Laboratory Taiwan cabinet and seats should be firm, corners should be smooth.

6.1.6 Laboratory Taiwan cabinet, etc., and its place should be easy to clean, test table should be waterproof, corrosion-resistant, heat-resistant and strong.

6.1.7 The laboratory shall have sufficient space station and placed in cabinets and other laboratory equipment and supplies.

6.1.8 should be based on the nature of work and processes arrange the laboratory equipment, the Taiwan cabinet, articles, etc., to avoid mutual interference, cross-contamination and should wish Hinder escape and first aid.

6.1.9 The laboratory can use natural ventilation. If the use of mechanical ventilation, avoid cross-contamination.

6.1.10 If you have windows that can be opened, should be installed anti-mosquito screens.

6.1.11 The laboratory shall avoid unnecessary internal reflections and glare.

6.1.12 If the operation of irritation or corrosive substances should be 30m equipped with an eyewash, as necessary, provided emergency sprinklers.

6.1.13 If the operation of toxic, irritating, volatile radioactive substances should be based on risk assessment, with appropriate negative pressure ventilation cabinet.

6.1.14 The use of highly toxic, radioactive and other substances, should be equipped with appropriate safety facilities, equipment and personal protective equipment shall comply with national, Party relevant regulations and requirements.

6.2 BSL-2 laboratory

6.2.1 When applicable, shall comply with the requirements of 6.1.

6.2.2 The laborat...

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 36 pages — is available in the English PDF.

Referenced standards

Cited by

Similar standards

GB 27421-2015|GB 14925-2010|GB 50346|GB 19781|GB 50447|GB/T 32146.1

How to Buy GB 19489-2008

  1. 1Add to cart. Click the "Buy GB 19489-2008" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
36 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB 19489-2008

$160.00

$135.00for partners