GB/T 44830-2024General rules for determination of enzyme-linked immunosorbent assay kit (English PDF)
酶联免疫试剂盒检测通则
Open the GB/T 44830-2024 preview as PDF
This is a limited preview
Buy now to download the full PDF (9 pages)
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
October 26, 2024
Implementation date
October 26, 2024
Scope
GB/T 44830-2024 is the English-translated version of 酶联免疫试剂盒检测通则.
GB/T 44830-2024 sets the general rules for testing with enzyme-linked immunosorbent assay kits. ELISA kits are the workhorse of food, feed and environmental screening in China - for mycotoxins, veterinary drug residues, allergens and pathogens - because they are cheap, quick and usable outside a specialist laboratory; that same accessibility is why results vary so much between users, since the kit insert is the only protocol and it differs from maker to maker. The standard describes the assay process and sets the general requirements for performing it and for the result report, with informative annexes on the criteria for evaluating precision within the working range and on evaluating agreement with a reference method. It took effect on 26 October 2024.
Document preview — GB/T 44830-2024
National Standard of the People's Republic of China
- ICS
- 07.080
- Classification
- A40
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- 1 Scope
- 2 Normative References
- 3 Terms and Definitions
- 4 General Requirements
- 5 Assay Procedures
- 5.1 Selection and Preparation of Assay Sample
- 5.4 Result Calculation
1 Scope
GB/T 44830-2024 sets the general rules for testing with enzyme-linked immunosorbent assay kits. ELISA kits are the workhorse of food, feed and environmental screening in China - for mycotoxins, veterinary drug residues, allergens and pathogens - because they are cheap, quick and usable outside a specialist laboratory; that same accessibility is why results vary so much between users, since the kit insert is the only protocol and it differs from maker to maker. The standard describes the assay process and sets the general requirements for performing it and for the result report, with informative annexes on the criteria for evaluating precision within the working range and on evaluating agreement with a reference method. It took effect on 26 October 2024.
This document describes the assay process of an enzyme-linked immunosorbent assay kit and specifies the general requirements for assay by the enzyme-linked immunosorbent assay kit and result report. This document applies to assay by the enzyme-linked immunosorbent assay kit.
2 Normative References
The contents of the following documents constitute indispensable clauses of this document through the normative references in the text. In terms of references with a specified date, only versions with a specified date are applicable to this document. In terms of references without a specified date, the latest version (including all the modifications) is applicable to this document.
GB/T 4889-2008 Statistical Interpretation of Data - Techniques of Estimation and Tests Relating to Means and Variances of Normal Distribution
GB 19489 Laboratories - General Requirements for Biosafety
3 Terms and Definitions
The following terms and definitions are applicable to this document.
3.1 negative sample A sample in which the target analyte is not detected by standard laboratory analytical methods or classical methods.
3.2 positive sample A sample in which the target analyte is detected by standard laboratory analytical methods or classical methods.
4 General Requirements
4.1 Enzyme-Linked Immunosorbent Assay Kit The enzyme-linked immunosorbent assay kit shall be in complete packaging; labels and markings shall be clear and standardized; an instruction manual or equivalent guidance document shall be attached, and the document shall include at least the following contents.
b) Scope of application. including the target analyte and applicable matrix range of assay;
c) Assay principle;
d) Kit composition, storage conditions and expiration date;
e) Equipment and reagents required for tests;
f) Operating instructions. including solution preparation, sample preparation, detailed assay procedures and result calculation;
g) Precautions. including key operating points, safety tips, analysis and solutions to common problems.
4.2 Laboratory Laboratory biosafety management shall comply with the relevant requirements in GB 19489.
4.3 Assay Indicators Standard curve, limit of detection, precision, accuracy and cross-reactivity.
5.1 Selection and Preparation of Assay Sample
5.1.1 Negative and positive samples shall have matrix compatibility and similarity to the actual sample in terms of components other than the target analyte.
5.1.2 Positive or negative samples should preferably use nationally certified matrix standard samples/standard substances, reference substances, or quality control materials. If these are unavailable, they can be prepared in-house. Appropriate laboratory standard analytical methods or classical methods shall be selected to determine the target analyte in the sample using instruments. Confirm that all negative samples are below the limit of detection and confirm the content of the target analyte in all positive samples.
5.1.3 Positive and negative samples, and samples to be tested shall all be pre-treated in accordance with the steps in the enzyme-linked immunosorbent assay kit's instruction manual.
5.2 Reagent Preparation Remove the kit from the storage environment and allow it to equilibrate to room temperature (23 C 2 C). Then, operate in accordance with the enzyme-linked immunosorbent assay kit's instruction manual.
5.3 Operating Procedures Each sample and standard solution shall be repeatedly determined at least twice, following the steps in the enzyme-linked immunosorbent assay kit's instruction manual.
5.4 Result Calculation
5.4.1 Standard curve The standard curve consists of at least 6 concentrations. Operate in accordance with the enzyme-linked immunosorbent assay kit's instruction manual, determine the absorbance value of each concentration, take the average value, and plot a four-parameter fitted standard curve or other specified standard curve. For accurate quantitative methods, the coefficient of determination (R^2) of the linear regression equation shall be no less than 0.99. Use the absorbance value of the calibrator as the y-coordinate and the concentration of the calibrator as the x-coordinate to perform a four-parameter curve fitting, establish the equation in accordance with Formula (1), and calculate the correlation coefficient. Where, y
---the absorbance value; d
---the minimum absorbance value; a
---the maximum absorbance value, upper asymptote of the fitted curve; X
---the concentration of the calibrator; EC50
---the median effect concentration; b
---the absorbance increase rate parameter, i.e., the slope of the curve at EC50. Correlation coefficient calculation. the correlation coefficient is calculated using data statistical processing software.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 9 pages — is available in the English PDF.
Referenced standards
Similar standards
GB 38031-2025|GB/T 4889-2008|GB 19489|GB 19489.|GB/T 40179|GB/T 40267|GB/T 40980|GB/T 47334
How to Buy GB/T 44830-2024
- 1Add to cart. Click the "Buy GB/T 44830-2024" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 19489-2008 — Laboratories - General requirements for biosafety
GB/T 47310-2026 — Determination of total silicon, aluminium, iron, potassium, sodium, calcium, magnesium, manganese, phosphorus, titanium and sulfur in soil - Monochromatic excitation energy dispersive X-ray fluorescence spectrometry
GB/T 47321-2026 — Specification for the warning data exchange of the national emergency early warning dissemination system
Secure payment via Stripe
Payments accepted
GB/T 44830-2024
$200.00