GB/T 2423.22-2012 is the English-translated version of 环境试验 第2部分:试验方法 试验N:温度变化.
GB/T 2423.22 specifies Test N, change of temperature, one of the most used environmental tests there is. It is not the same thing as a high or low temperature test: what it looks for is the damage done by the change itself, the differential expansion between materials in an assembly, the cracking of seals and solder joints, the condensation that forms when a cold item is brought into warm air. The standard defines the several variants of the test, the slow change at a specified rate, the rapid change with two chambers between which the specimen is transferred, the rapid change by immersion in liquid baths, and the specification of each: the temperature extremes, the rate of change, the dwell time at each extreme, the number of cycles, the transfer time, the conditions before and after the test and the recovery period, together with the requirements on the chambers and the mounting of the specimen and on the severities to be selected. It is aligned with IEC 60068-2-14. For a manufacturer, a specification writer or a test house in China, this is the referenced procedure.
Document preview — GB/T 2423.22-2012
National Standard of the People's Republic of China
- ICS
- 19.040
- Classification
- K04
- Replacing
- GB/T 2423.22-2002
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- 1 Scope
- 2 Na test cycle
- 3 Nb test cycle
- 4 General
- 5 Test Type Selection Guide
- 6 Initial detection and final detection
- 7 Test Na. specifies the rapid temperature change of the switching time
- 7.2 Test procedure
- 8 Test Nb. temperature change specifying the rate of change
- 8.2 Test procedure
- 9 Test Nc. rapid change of temperature in two-tank method
- 9.2 Test procedure
- 17 Environmental testing - Part 2-17: Test method test Q. Seals
Foreword
This part is the 22nd part of the GB/T 2423 standard. The components of the GB/T 2423 standard are listed in the informative appendix NA. This part is drafted in accordance with the rules given in GB/T 1.1-2009. This part replaces GB/T 2423.22-2002 "Electrical and Electronic Products Environmental Test Part 2. Test Method Test N. Temperature "Changes" and GB/T 2424.13-2002 "Electrical and Electronic Products Environmental Testing Part 2. Test Methods Temperature Change Test Guide". This part is mainly based on GB/T 2423.22-2002, which integrates part of GB/T 2424.13-2002 with GB/T 2423.22- In.2002, compared with GB/T 2424.13-2002, the main technical changes and editorial changes are as follows:
--- Test Na and test Nb, remove the relevant requirements for absolute humidity, tank wall temperature and air flow rate of the test chamber (see 7.2.1, 8.2.1);
--- Test Na, the provisions of the test chamber allowed to use a rapid temperature change rate are increased (see 7.2.1);
--- Test the severity of the Na and test Nb, increasing the "exposure duration" parameter (see 7.2.3, 8.2.3);
--- Test Na, deleted the "conversion time should be. (2 ~ 3) min, (20 ~ 30) s, < 10s" provisions, replaced by "conversion time T2 should not exceed 3 minutes" (see 7.2.5);
--- Test Nb, increased two preferred values of temperature change rate. (10 ± 2) K/min and (15 ± 3) K/min (see 8.2.3);
--- Test Nc, deleted two sets of standardized duration parameters;
--- The unit of temperature deviation replaces "°C" with "K";
--- Deleted the contents of
3.4.2 and Chapter 4 of GB/T 2424.13-2002;
--- Updated the contents of
3.3 of GB/T 2424.13-2002;
--- Updated all the diagrams;
--- Combine the contents of the test Na, the test Nb, and the test Nc "initial and final test" into a separate chapter 6;
1 Scope
GB/T 2423.22 specifies Test N, change of temperature, one of the most used environmental tests there is. It is not the same thing as a high or low temperature test: what it looks for is the damage done by the change itself, the differential expansion between materials in an assembly, the cracking of seals and solder joints, the condensation that forms when a cold item is brought into warm air. The standard defines the several variants of the test, the slow change at a specified rate, the rapid change with two chambers between which the specimen is transferred, the rapid change by immersion in liquid baths, and the specification of each: the temperature extremes, the rate of change, the dwell time at each extreme, the number of cycles, the transfer time, the conditions before and after the test and the recovery period, together with the requirements on the chambers and the mounting of the specimen and on the severities to be selected. It is aligned with IEC 60068-2-14. For a manufacturer, a specification writer or a test house in China, this is the referenced procedure.
4.6 Application limits for temperature change tests Within the test sample, the rate of temperature change depends on the thermal conductivity of the test sample material, the spatial distribution of the test sample heat capacity, and the test. Sample size. The temperature change at a point on the surface of the test sample generally follows an exponential law. Within the large test sample, such an alternating exponential rise And falling results in a periodic, approximately sinusoidal temperature change that is much lower than the magnitude of the alternating temperature applied. The heat transfer mechanism between the test sample and the conditioning medium in the tank or tank should be considered. The flowing liquid causes the surface of the test sample to be very high The rate of temperature change, while still air causes a very low rate of change. The two-tank method (test Nc) with water as the medium of regulation should be limited to sealed test samples or test samples with water-insensitive properties. Product, because the performance and characteristics of the test sample may be degraded by water immersion. In certain cases, such as test samples that are sensitive to water, it is necessary to stipulate the use of other liquids that are not water for testing. When designing this test During the inspection, it should be considered that the heat transfer characteristics of the liquid used may be different from water.
Note. The evaluation results obtained from Test Q. Seal (IEC 60068-2-17) may be helpful in evaluating the applicability of the two tank method.
2 Na test cycle
7.3 Recovery At the end of the test cycle, the test sample shall be held for a sufficient period of time under test standard atmospheric conditions to achieve temperature stability. For a particular type of test sample, the relevant specification can specify a specific recovery time.
7.4 Information to be given in the relevant specifications When the relevant specification contains this test, any of the following applicable details should be given.
a) type of test;
b) pretreatment;
c) initial detection;
d) installation and support details;
e) low temperature TA, high temperature TB;
f) exposure duration t1;
g) the number of cycles;
h) detection and/or load during the conditional test;
j) final detection;
k) Any deviation from the program agreed between the customer and the supplier.
3 Nb test cycle
8.3 recovery At the end of the test cycle, the test sample shall be held for a sufficient period of time under test standard atmospheric conditions to achieve temperature stability. For a particular type of test sample, the relevant specification can specify a specific recovery time.
8.4 Information to be given by the relevant specifications When the relevant specification contains this test, any of the following applicable details should be given.
a) type of test;
b) pretreatment;
c) initial detection;
d) installation and support details;
e) low temperature TA, high temperature TB;
f) exposure duration t1;
g) temperature change rate;
h) the number of cycles;
i) detection and/or load during conditional testing;
k) final detection;
l) Any deviation from the program agreed between the customer and the supplier.
4 General
4.1 Design of temperature change test Tests Na, Nb, and Nc include alternating high temperature and low temperature periods, and the conversion from one temperature to another is also well defined. From the laboratory ambient temperature to the first condition test temperature, then to the second condition test temperature, and then back to the laboratory ambient temperature The knot process is considered a test cycle.
4.2 Test parameters Test parameters include the following.
---Test room ambient temperature;
---high temperature;
---low temperature;
---Exposure duration;
--- Conversion time or rate of change;
---The number of test cycles. High temperature and low temperature refer to the ambient temperature, which is reached by most test samples, but the time is delayed. Only in exceptional cases can the high temperature or low temperature be specified for normal storage or outside the operating temperature range of the test sample. Since the number of sudden changes in temperature during a given time is greater than the number of occurrences of field conditions, the test is accelerated.
4.3 Purpose of the test and selection of test methods It is recommended to select the temperature change test as follows:
--- Evaluation of electrical properties under temperature changes, select test Nb;
--- Evaluation of mechanical properties under temperature changes, select test Nb;
---Evaluate the electrical performance after a specified number of rapid temperature changes, select test Na or test Nc;
---Evaluate whether the mechanical parts, materials and material combinations are suitable for withstanding rapid temperature changes, choose test Na or test Nc;
--- Evaluate whether the structure of the component is suitable for withstanding artificial stress, and choose test Na or test Nc. The temperature change test specified in GB/T 2423 is not used to evaluate the test sample to work under two extreme conditions of extreme temperature. Material stability or electrical performance differences.
5 Test Type Selection Guide
The severity of the test increases with temperature differences, rate of temperature change, and heat transfer to the test sample. Test N is preferably used as part of the sequence test. Some types of damage may not be obvious in the final test of test N, but only Will appear in subsequent tests (for example, Test Q. Seal, Test Fc. Vibration or Test Db. Alternating Damp Heat 1)). The temperature change test Nc (two-tank method) should not be used instead of the test Q (sealing). When specifying a temperature change test, attention should be paid to the characteristics of the test sample affected by temperature change conditions and their possible failure mechanisms. Reason. The initial test and the final test should be accordingly specified accordingly.
6 Initial detection and final detection
The requirements for initial and final testing of tests Na, Nb and Nc are as follows: 1) IEC 60068-2-14.2009 original text is "Test F. Vibration or Test D. Accelerated Damp Heat", but in the test method specified in IEC 60068, there is no "test" Test D. Accelerate damp heat, "Test F" is also divided into several methods, so it is still corrected here as IEC 60068-2-33.1971.
6.1 Initial detection The test samples shall be visually inspected and tested for electrical and mechanical properties in accordance with the relevant specifications.
6.2 Final inspection The test samples shall be visually inspected and tested for electrical and mechanical properties in accordance with the relevant specifications.
7 Test Na. specifies the rapid temperature change of the switching time
7.1 Test Overview This test determines the ability of components, equipment, or other products to withstand rapid changes in ambient temperature. Exposure time required to achieve this Depends on the nature of the test sample. The test sample shall be in a state of being unpackaged, not energized, ready for use, or otherwise specified by relevant specifications. The test sample is exposed to rapidly changing air or a suitable inert gas and is alternately exposed to high temperatures and low temperatures.
7.2 Test procedure
7.2.1 Test box Two separate temperature chambers or one chamber with a fast temperature change rate can be used. If you use two test chambers, one test The test chamber is used for low temperature, one test chamber is used for high temperature, and the position of the two test chambers is such that the test sample is transferred from one test chamber to another. The box can be completed within the specified time. Manual or automatic conversion methods can be used. Any area in which the test sample is placed in the test chamber shall be capable of maintaining the air temperature specified in the test. After the test sample is placed, the air temperature should reach the specified tolerance within 10% of the exposure duration.
7.2.2 Installation or support of test samples Unless otherwise specified in the relevant specifications, the mounting or support frame should have low thermal conductivity so that the test sample is actually thermally insulated. When several When the test sample is tested at the same time, the test sample shall be placed so that the air between the test sample, the test sample and the inner surface of the test chamber is free. Circulation.
7.2.3 Severity rating The severity of the test is determined by the combination of two temperatures, conversion time, exposure duration, and number of cycles. The relevant specifications shall specify a low temperature TA and shall be selected from the test temperatures specified in IEC 60068-2-1 and IEC 60068-2-2. The relevant specifications shall specify high temperature TB and shall be selected from the test temperatures specified in IEC 60068-2-1 and IEC 60068-2-2. The exposure duration t1 at two temperatures depends on the heat capacity of the test sample. The duration of exposure can be 3h, 2h, 1h, 30 min, 10 min or the time specified in the relevant specifications. When the relevant specification does not specify the exposure duration, then the time is 3h. Unless otherwise specified in the relevant specifications, the preferred number of test cycles is 5.
Note. The exposure time of 10 min is suitable for the test of small test samples.
7.2.4 Conditional test initial state The temperature in the test sample and test chamber shall be at the laboratory ambient temperature, 25 ° C ± 5K. If the relevant specifications require, the test sample should be made The product begins to enter the running state.
7.2.5 Test cycle The test sample was exposed to a low temperature TA. The temperature TA should be maintained for the specified time t1. T1 includes the temperature stabilization time of the air in the tank, which is no longer than
0.1 t1 (see 7.2.1).
Note 1. The duration of exposure is calculated from the moment the test sample is placed in the temperature chamber. The test sample is then switched to exposure to high temperature TB, and the conversion time t2 should not exceed 3 minutes. T2 shall include the time from which the test sample is removed from one test chamber, the time it is placed in the second test chamber, and the ambient temperature at the test chamber. The time of stay.
Note 2. For high quality test samples, the conversion time from one test chamber to another can be increased according to the relevant standards or specifications. The temperature TB should be maintained for the specified time t1. T1 includes the temperature stabilization time of the air in the tank, which is no longer than
0.1 t1 (see 7.2.1).
Note 3. The duration of exposure is calculated from the moment the test sample is placed in the temperature chamber. For the next cycle, the test sample should be switched to exposure to low temperature TA, and the conversion time t2 should not exceed 3 min. The first cycle includes 2 exposure times t1 and 2 conversion times t2 (see Figure 2). At the end of the last cycle, the test sample should be subjected to a recovery procedure. Description. A
---the first cycle begins; B
---The first cycle ends and the second cycle begins.
Note 1. The dotted line has been explained before. IEC TC104 has been confirmed and corrected here. Figure
8 Test Nb. temperature change specifying the rate of change
8.1 Test Overview This test determines the tolerance and normal function of components, equipment or other products under ambient temperature changes. The test sample shall be in a state of being unpackaged, not energized, ready for use, or otherwise specified by relevant specifications. The test sample is exposed to temperature-changing air in the test chamber, the test chamber is maintained at the specified temperature value, and is controlled at a controlled rate. Chemical. The performance of the test sample can be monitored during the exposure.
8.2 Test procedure
8.2.1 Test box The test chamber for this test shall be designed such that the temperature cycle in the work space in which the test sample is placed is operated.
a) can maintain the low temperature required by the test;
b) can maintain the high temperature required by the test;
c) The rate of change from low to high or from high to low can meet the test requirements.
8.2.2 Installation or support of test samples Unless otherwise specified in the relevant specifications, the mounting or support frame should have low thermal conductivity so that the test sample is actually thermally insulated. When several When the test sample is tested at the same time, the test sample shall be placed so that the air between the test sample, the test sample and the inner surface of the test chamber is free. Circulation.
8.2.3 Severity rating The severity of the test is determined by the combination of two temperatures, rate of temperature change, duration of exposure, and number of cycles. The relevant specifications shall specify a low temperature TA and shall be selected from the test temperatures specified in IEC 60068-2-1 and IEC 60068-2-2. The relevant specifications shall specify high temperature TB and shall be selected from the test temperatures specified in IEC 60068-2-1 and IEC 60068-2-2. In the range between 90% and 10% of the test temperature difference D (= TB-TA), the tolerance of the air temperature decrease or increase rate should be within the gauge Within 20% of the fixed rate. Unless otherwise specified in the relevant specifications, the preferred values for the rate of temperature change are. (1±0.2) K/min; (3±0.6) K/min; (5±1) K/min; (10±2) K/min; (15 ± 3) K/min. The exposure duration t1 at two temperatures depends on the heat capacity of the test sample. The duration of exposure can be 3h, 2h, 1h, 30 min, 10 min or the time specified in the relevant specifications. When the relevant specification does not specify the exposure duration, then the time is 3h. Test samples shall be tested continuously for 2 cycles unless otherwise specified in the relevant specifications.
8.2.4 Conditional test initial state The temperature in the test sample and test chamber shall be at the laboratory ambient temperature, 25 ° C ± 5K. If the relevant specifications require, the test sample should be made The product begins to enter the running state.
8.2.5 Test cycle The air temperature in the chamber is lowered to the specified low temperature TA at a specified rate (see Figure 3). After the temperature in the tank has stabilized, the test sample shall be exposed to low temperature conditions for a specified time t1. The air temperature in the chamber is then raised to the specified high temperature TB at a specified rate (see Figure 3). After the temperature in the tank has stabilized, the test sample shall be exposed to high temperature for a specified time t1. The air temperature in the chamber is then reduced to the laboratory ambient temperature at a specified rate, 25 ° C ± 5 K (see Figure 3). The above process constitutes a loop. Description. A
---The first cycle begins. Figure
9 Test Nc. rapid change of temperature in two-tank method
9.1 Test Overview This test determines the ability of components, equipment, or other products to withstand rapid temperature changes. This test procedure results in severe thermal shock and is suitable for glass-to-metal seals and similar test specimens. The test samples were alternately immersed in two tanks, one tank containing a low temperature TA liquid and one tank containing a high temperature TB liquid.
9.2 Test procedure
9.2.1 Test equipment Two liquid tanks, one low temperature tank and one high temperature tank should be arranged so that the test sample can be easily immersed in the liquid tank or quickly from a liquid The tank is switched to another tank. The cryogenic liquid tank should be able to maintain the liquid temperature at the low temperature TA specified by the relevant regulations. If there is no specified temperature, the liquid temperature should be 0 °C. The high temperature liquid tank should be able to keep the liquid temperature at the high temperature TB specified in the relevant regulations. If there is no specified temperature, the temperature of the liquid should be 100 ° C. The structure of the liquid tank should be such that the temperature rise of the low temperature liquid tank should not exceed 2K of TA at any time of the test, and the high temperature liquid tank The temperature drop should not be lower than 5K of TB. The liquid used in the test shall be compatible with the materials and protective layers used in the manufacture of the test sample.
Note. The heat transfer rate depends on the liquid used and affects the severity of the test for a given temperature range. In special cases, relevant specifications should be specified The liquid used.
9.2.2 Severity rating The severity of the test is determined by the specified two tank temperatures, the transition time t2 from one tank to the other, and the number of cycles. The relevant specification should specify the duration parameter used and the selected value of t1. The number of test cycles is 10 unless otherwise specified in the relevant specifications.
9.2.3 Conditional test initial state Test samples should be tested without packaging.
9.2.4 Test cycle The test sample at the laboratory ambient temperature is immersed in a cryogenic liquid tank, and the liquid temperature in the tank is the temperature TA specified by the relevant specification. The test sample shall be kept submerged in the cryogenic tank for the time t1 specified. The test sample is then removed from the cryogenic liquid tank and immersed in a high temperature liquid bath in which the liquid temperature is the temperature TB specified in the relevant specification. The conversion time t2 shall comply with the relevant specifications. The test sample shall be kept submerged in the high temperature bath for the time t1 specified. The test sample is then removed from the high temperature bath. The conversion time t2 of the test sample taken out of the high temperature liquid tank and immersed in the low temperature liquid tank Should comply with the relevant regulations. One cycle consists of 2 immersion times t1 and 2 conversion times t2 (see Figure 4). At the end of the last cycle, the test sample should be subjected to a recovery procedure. Description. A
---The first cycle begins. Figure
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
IEC 60068
Cited by
- GB 23826-2025Light-emitting diode variable speed limit signs of motorway
- GB/T 18334-2025Specification for flexible multilayer printed boards
- GB/T 20643.2-2025Specific environmental condition — Environmental test method — Part 2: Artificial environment test method and guidance — Electric and electronic products (including communication products)
- GB/T 20643.3-2025Special environmental condition — Environmental test method — Part 3: Artificial environmental test method and guidance — Polymer material
- GB/T 20965-2025Control network HBES technical specification — Home and building control system
- GB/T 22040-2025Technical requirements and test of weathering quality for plastics of highway furnitures
How to Buy GB/T 2423.22-2012
- 1Add to cart. Click the "Buy GB/T 2423.22-2012" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 2423.101-2025 — Environmental testing - Part 2: Test methods - Test: Inclinations and swings
GB/T 2423.102-2008 — Environmental testing for electric and electronic products - Part 2: Test methods - Test: combined temperature(cold and heat)/low air pressure/vibration (sinusoidal)
GB/T 2423.17-2024 — Environmental testing - Part 2: Test methods - Test Ka: Salt mist
Secure payment via Stripe
Payments accepted
GB/T 2423.22-2012
$290.00