GB/T 17626.9-2025Electromagnetic compatibility - Testing and measurement techniques - Part 9: Impulse magnetic field immunity test (English PDF)
电磁兼容 试验和测量技术 第9部分:脉冲磁场抗扰度试验
This is a limited preview
Buy now to download the full PDF (46 pages)
Need quotation for your management?
Get a formal quotation for GB/T 17626.9-2025 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
October 31, 2025
Implementation date
May 1, 2026
Scope
GB/T 17626.9-2025 is the English-translated version of 电磁兼容 试验和测量技术 第9部分:脉冲磁场抗扰度试验.
GB/T 17626.9-2025 is the Chinese standard "Electromagnetic compatibility - Testing and measurement techniques - Part 9: Impulse magnetic field immunity test".
Its scope clause reads: This document specifies the immunity requirements, test methods, and recommended tests for equipment subjected to pulsed magnetic field disturbances primarily from the following locations.
The applicability of this document to devices installed in different locations is determined by the phenomena described in Chapter 4. This document does not consider interference caused by capacitive and inductive coupling in cables or other parts of field facilities.
The purpose of this document is to establish a general standard for evaluating the immunity of electrical and electronic equipment to pulsed magnetic fields.
Found what you need?
Document preview — GB/T 17626.9-2025
National Standard of the People's Republic of China
- ICS
- 33.100.20
- Classification
- L 06
- Replacing
- GB/T 17626.9-2011
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Preface
- Introduction
- 1 Scope
- 2 Normative References
- 3 Terms, Definitions, and Abbreviations
- 3.1 Terms and Definitions
- 3.2 Abbreviations
- 4 General Provisions
- 5 Test Level
- 6 Test equipment
- 6.1 Overview
- 6.2 Combined Wave Generator
- 6.2.1 General Rules
- 6.2.2 Characteristics of the Generator
- 6.2.3 Generator Calibration
- 6.3 Induction Coil
- 6.3.1 Magnetic Field Distribution
- 6.3.2 Characteristics of standard induction coils of 1mx1m and 1mx2.6m
- 6.4 Calibration of the test system
- 7 Test Configuration
- 7.1 Test Equipment
- 7.2 Verification of the testing instruments
- 7.3 Pulse Magnetic Field Configuration for Desktop Equipment
- 7.4 Pulsed magnetic field configuration for floor-standing equipment
- 7.5 Pulsed magnetic field test setup for field use
- 8 Experimental Procedure
- 8.1 Overview
- 8.2 Laboratory Reference Conditions
- 8.2.1 Climatic Conditions
- 8.2.2 Electromagnetic Environment
- 8.3 Implementation of the Experiment
- 9 Evaluation of Experimental Results
- 10 Test Report
- Appendix A (Informative) Characteristics of Non-standard Induction Coils
- A.1 Overview
- A.2 Determination of Coil Factor
- A.2.1 General Requirements
- A.2.2 Coil Factor Measurement
- A.2.3 Coil Factor Calculation
- A.3 Magnetic Field Measurement
- A.4 Verification of Non-standard Induction Coils
- Appendix B (Informative) Magnetic Field Distribution Information of Standard Induction Coils
- B.1 Overview
- B.2 1mx1m induction coil
- B.3 1mx2.6m induction coil with reference grounding
- B.4 1mx2.6m unreferenced grounded plane induction coil
- Appendix C (Informative) Selection of Test Level
- Appendix D (Informative) Considerations for Measurement Uncertainty (MU)
- D.1 Overview
- D.2 Explanation
- D.3 Uncertainty Components of Surge Current and Surge Magnetic Field Measurements
- D.4 Uncertainty of Surge Current and Surge Magnetic Field Calibration
- D.4.1 Overview
- D.4.2 Wavefront Time of Surge Current
- D.4.3 Peak values of surge current and magnetic field
- D.4.4 Duration of Pulse Current
- D.4.5 Other MU components introduced by time measurement
- D.4.6 Rise time distortion due to limited bandwidth of the measurement system
- D.4.7 Pulse peak and width distortion due to the limited bandwidth of the measurement system
- D.5 Application of Uncertainty in Surge Generator Compliance Assessment
- Appendix E (Informative) Mathematical Model of Surge Current Waveform
- E.1 Overview
- E.2 Normalized time-domain surge current (8/20µs)
- Appendix F (Informative) Characteristics using two standard induction coils
- F.1 Overview
- F.2 Special Requirements for Calibration
- F.3 Field distribution of dual induction coil arrangement
- Appendix G (Informative) 3D Numerical Simulation
- G.1 Overview
- G.2 Simulation
- G.3 Note
- References
Foreword
This document complies with the provisions of GB/T 1.1-2020 "Standardization Work Guidelines Part 1: Structure and Drafting Rules of Standardization Documents". Drafting.
This document is Part 9 of GB/T (Z)17626, "Electromagnetic Compatibility Testing and Measurement Techniques". GB/T 17626 has been published as follows. Part 2.
---GB /Z 17626.1-2024 Electromagnetic compatibility testing and measurement techniques - Part 1: General principles of immunity testing;
---GB/T 17626.2-2018 Electromagnetic compatibility testing and measurement techniques - Electrostatic discharge immunity test;
---GB/T 17626.3-2023 Electromagnetic compatibility testing and measurement techniques - Part 3: Immunity to Radiated Radio Frequency Electromagnetic Fields test;
---GB/T 17626.4-2018 Electromagnetic compatibility testing and measurement techniques - Electrical fast transient/burst immunity test;
---GB/T 17626.5-2019 Electromagnetic compatibility testing and measurement techniques - Surge (impulse) immunity test;
---GB/T 17626.6-2017 Electromagnetic compatibility testing and measurement techniques - Conducted disturbance immunity induced by radio frequency fields;
---GB/T 17626.7-2017 Electromagnetic Compatibility Testing and Measurement Techniques - Measurement of Harmonics and Interharmonics in Power Supply Systems and Connected Equipment Guidelines for Measurement and Measuring Instruments;
---GB/T 17626.8-2006 Electromagnetic compatibility testing and measurement techniques - Power frequency magnetic field immunity test;
---GB/T 17626.10-2017 Electromagnetic compatibility testing and measurement techniques - Damped oscillating magnetic field immunity test;
---GB/T 17626.11-2023 Electromagnetic compatibility testing and measurement techniques - Part 11: For input currents less than or equal to per phase Immunity tests for voltage dips, short interruptions, and voltage variations in 16A equipment;
---GB/T 17626.12-2023 Electromagnetic compatibility testing and measurement techniques - Part 12: Ringing wave immunity test;
---GB/T 17626.13-2006 Electromagnetic Compatibility Testing and Measurement Techniques - Harmonics, Interharmonics and Electromagnetic Waves at AC Power Ports Low-frequency immunity test of the number;
---GB/T 17626.14-2005 Electromagnetic compatibility testing and measurement techniques - Voltage fluctuation immunity test;
---GB/T 17626.15-2011 Electromagnetic Compatibility Testing and Measurement Technology - Functional and Design Specifications for Scintillation Meters;
---GB/T 17626.16-2007 Electromagnetic compatibility testing and measurement techniques - Common-mode conducted disturbance immunity (0Hz~150kHz) test;
---GB/T 17626.17-2005 Electromagnetic compatibility testing and measurement techniques - DC power supply input port ripple immunity test;
---GB/T 17626.18-2016 Electromagnetic compatibility testing and measurement techniques - Damped oscillating wave immunity test;
---GB/T 17626.19-2022 Electromagnetic compatibility testing and measurement techniques - Part 19: AC power supply ports 2kHz~ 150kHz differential-mode conducted interference and communication signal immunity test;
---GB/T 17626.20-2014 Electromagnetic Compatibility Testing and Measurement Techniques. Emission and Immunity in Transverse Electromagnetic Waveguides (TEM) Degree test;
---GB/T 17626.21-2014 Electromagnetic compatibility testing and measurement techniques - Mixing chamber test method;
---GB/T 17626.22-2017 Electromagnetic Compatibility Testing and Measurement Techniques - Radiated Emissions and Immunity in Anechoic Chambers Measurement;
---GB/T 17626.24-2012 Electromagnetic Compatibility Testing and Measurement Techniques - Testing of Conducted Disturbance Protection Devices for HEMP method;
---GB/T 17626.27-2006 Electromagnetic compatibility testing and measurement techniques - Three-phase voltage imbalance immunity test;
---GB/T 17626.28-2006 Electromagnetic compatibility testing and measurement techniques - Power frequency variation immunity test;
---GB/T 17626.29-2006 Electromagnetic Compatibility Testing and Measurement Techniques - DC Power Supply Input Port Voltage Drop, Short-Time Instantaneous Voltage Dips Immunity test under interruption and voltage variation;
---GB/T 17626.30-2023 Electromagnetic compatibility testing and measurement techniques - Part 30: Power quality measurement methods;
---GB/T 17626.31-2021 Electromagnetic compatibility testing and measurement techniques - Part 31: Broadband conducted noise at AC power ports Disturbance immunity test;
---GB /Z 17626.33-2023 Electromagnetic compatibility testing and measurement techniques - Part 33: Methods for measuring high-power transient parameters;
---GB/T 17626.34-2012 Electromagnetic Compatibility Testing and Measurement Techniques for Equipment with Main Power Supply Current Greater Than 16A Per Phase Voltage sag, short interruption and voltage change immunity tests;
---GB/T 17626.36-2024 Electromagnetic compatibility testing and measurement techniques - Part 36: Intentional electromagnetic interference in equipment and systems Disturbance immunity test methods;
---GB/T 17626.39-2023 Electromagnetic compatibility testing and measurement techniques - Part 39: Immunity to near-field radiated fields test.
This document replaces GB/T 17626.9-2011 "Electromagnetic Compatibility Testing and Measurement Techniques - Pulse Magnetic Field Immunity Test", and is consistent with... Compared with GB/T 17626.9-2011, apart from structural adjustments and editorial changes, the main technical changes are as follows.
---The test configuration for the desktop equipment has been changed (see 7.3, 7.2 in the 2011 version);
---The requirement that the background electromagnetic field in the laboratory should be at least 20 dB lower than the selected test level has been removed (see 8.1.2 in the 2011 edition);
---The number of pulses required for the test has been changed (see 8.3, 8.2 in the 2011 version).
This document is equivalent to IEC 61000-4-9:2016 "Electromagnetic compatibility (EMC) - Part 4-9.Test and measurement techniques - Pulsed magnetic fields". Immunity test.
The following minimal editorial changes have been made to this document.
---To harmonize with existing standards, the standard title has been changed to "Electromagnetic Compatibility Testing and Measurement Techniques - Part 9: Immunity to Pulsed Magnetic Fields". Degree Test;
---The vertical axis of Figure 2 in the original IEC document was incorrect; this document has corrected it.
---In the second paragraph of IEC 6.4, there is an error in the phrase "specified in 6.2.1". The corrected translation is "specified in 6.3".
---In the original IEC text, paragraph 7.3, paragraph 3, the phrase "(see 7.4)" is incorrect. The corrected translation is "(see 7.5)".
---The parameter "A" in Table D.1 of the original IEC document is incorrect and should be changed to parameter "alpha";
---The first parameter "B" in Table D.2 of the original IEC document is incorrect and should be changed to parameter "beta".
Introduction
Electromagnetic compatibility (EMC) refers to the ability of electrical and electronic equipment or systems to function properly in their electromagnetic environment without posing a threat to anything in that environment.
The ability to withstand electromagnetic interference. Electromagnetic compatibility (EMC) issues are a significant factor affecting the environment and product quality, and standardization efforts have been undertaken.
This has attracted widespread attention both domestically and internationally. In this regard, the IEC 61000 series of standards developed by the International Electrotechnical Commission (IEC) are crucial for the manufacturing and information industries.
General standards in fields such as industry, electrical engineering and energy, transportation, social services and health, and consumer product quality and safety are divided into comprehensive standards.
The standards are categorized into six main types. description, environment, limits, testing and measurement techniques, installation and mitigation guidelines, and general standards. my country has already begun developing standards for this series.
Domestic transformation work has been carried out, and a corresponding national standard system has been established.
Within this standard system, GB/T (Z)17626 "Electromagnetic Compatibility Testing and Measurement Technology" pertains to testing and measurement in the field of electromagnetic compatibility.
The fundamental technical standards aim to describe immunity tests for electromagnetic compatibility phenomena such as conducted and radiated emissions, and are planned to be implemented by 40 organizations. Partial composition.
---Part 1: General Overview of Immunity Testing. The purpose is to provide usability guidelines for testing and measurement techniques in electromagnetic compatibility standards. It provides guidance and general advice on selecting relevant experiments.
---Part 2: Electrostatic Discharge Immunity Testing. The aim is to establish a universal and reproducible benchmark for evaluating electrical and electronic equipment. Performance under electrostatic discharge.
---Part 3: Radio Frequency Electromagnetic Field Radiation Immunity Test. The purpose is to establish immunity standards for electrical and electronic equipment when exposed to radio frequency electromagnetic field radiation. The criteria for evaluating immunity.
---Part 4: Electrical Fast Transient/Bulk Immunity Testing. The aim is to establish a universal and reproducible benchmark for evaluating electrical... Immunity of power supply ports, signal ports, control ports, and ground ports of electronic devices to electrical fast transient/burst interference. performance.
---Part 5: Surge (Impulse) Immunity Testing. The aim is to establish a universal and reproducible benchmark for evaluating electrical and electronic... The equipment's immunity to surges (impacts).
---Part 6: Conducted Disturbance Immunity Induced by Radio Frequency Fields. The aim is to establish a universal and reproducible benchmark for evaluating electrical... Immunity performance of electronic devices when subjected to conducted disturbances induced by radio frequency fields.
---Part 7: Guidelines for the measurement of harmonics and interharmonics in power supply systems and connected equipment. The purpose is to specify the methods and instruments that can be used to measure harmonics and interharmonics in power supply systems and connected equipment.
The equipment was tested item by item according to the emission limits given by certain standards, and the harmonic current and voltage in the actual power supply system were measured. The instrument.
---Part 8: Power Frequency Magnetic Field Immunity Testing. The aim is to establish a universal and reproducible benchmark for evaluating residential, commercial, and... Immunity performance of industrial electrical and electronic equipment in power frequency (continuous and short-term) magnetic fields.
---Part 9: Pulsed Magnetic Field Immunity Testing. The aim is to establish a universal and reproducible benchmark for evaluating residential, commercial, and... Immunity performance of industrial electrical and electronic equipment in pulsed magnetic fields.
---Part 10: Damped Oscillating Magnetic Field Immunity Test. The aim is to establish a universal and reproducible benchmark for evaluating medium- and high-voltage magnetic fields.
The disturbance rejection performance of electrical and electronic equipment in substations when exposed to damped oscillating magnetic fields.
---Part 11: Immunity Test for Voltage Sags, Short Interruptions and Voltage Variations for Equipment with Input Current Less Than or Equal to 16A Per Phase The purpose is to establish a universal and reproducible benchmark for evaluating the performance of electrical and electronic equipment under voltage dips and short-term interruptions. And the immunity performance under voltage changes.
---Part 12: Ringing Immunity Testing. The aim is to establish a universal and reproducible benchmark for evaluating electrical and electronic equipment. It has the ability to resist ringing waves.
---Part 13: Low-frequency immunity tests for AC port harmonics, interharmonics, and grid signals. The aim is to establish a universal and... A reproducible benchmark for evaluating the low-frequency immunity performance of electrical and electronic equipment to harmonics, interharmonics, and grid signal frequencies.
---Part 14: Voltage Fluctuation Immunity Testing. The aim is to establish a universal and reproducible benchmark for evaluating electrical and electronic... The equipment's immunity performance when subjected to low-amplitude positive and negative voltage fluctuations.
---Part 15: Scintillation Meter Functionality and Design Specifications. The aim is to display accurate scintillation for all actual voltage fluctuation waveforms. Perceived level.
---Part 16: Common-mode conducted disturbance immunity test from 0Hz to 150kHz. The purpose is to establish the immunity of electrical and electronic equipment to common-mode conducted disturbances. General and repeatability criteria for conducted disturbance tests.
---Part 17: DC Power Supply Input Port Ripple Immunity Test. The purpose is to establish a universal and reproducible benchmark for... When electrical and electronic equipment is charged from sources such as rectifier systems and/or batteries under laboratory conditions, the DC power supply is superimposed. Immunity test of ripple voltage on the device.
---Part 18: Damped Oscillating Wave Immunity Test. The aim is to establish a universal and reproducible benchmark for evaluating electrical and electronic systems.
The disturbance rejection performance of the sub-device when subjected to damped oscillating waves.
---Part 19: AC power port 2kHz~150kHz differential mode conducted interference and communication signal immunity test. The purpose is to... Verify that electrical and electronic equipment can withstand the loads from sources such as power electronics and power line communication systems (PLCs) when operating under a public power grid. Differential-mode conducted interference, etc.
---Part 20: Transmission and Immunity Tests in Transverse Electromagnetic Waveguides (TEM). The aim is to provide performance data for TEM waveguides.
Verification methods for TEM waveguides used for electromagnetic compatibility testing, and test procedures for radiated emission and immunity testing in TEM waveguides. Test setup, steps, and requirements.
---Part 21: Mixing Chamber Test Methods. The aim is to establish methods for evaluating electrical and electronic equipment in radio frequency electromagnetic fields using a mixing chamber.
The general specifications for performance and determining the radiated emission levels of electrical and electronic equipment.
---Part 22: Measurement of Radiated Emissions and Immunity in a Fully Anechoic Chamber. The purpose is to specify the procedures for measurement within the same fully anechoic chamber.
General verification procedures for radiated emissions and radiated immunity, test setup requirements for the equipment under test, and measurement methods in a fully anechoic chamber.
---Part 23: Test methods for HEMP and other radiated disturbance protection devices. The purpose is to describe the testing methods for HEMP.
Basic principles, and the theoretical basis (test concept), test configuration, required equipment, test procedures, and data processing of protective element tests. Important concepts such as reasoning.
---Part 24: Test methods for HEMP conducted disturbance protection devices. The purpose is to specify the test methods for HEMP conducted disturbance protection devices.
The test methods include voltage breakdown and voltage limiting characteristic tests, as well as residual voltage tests under rapid voltage and current changes. Measurement methods.
---Part 25: HEMP Immunity Test Methods for Equipment and Systems. The aim is to establish a universal and reproducible benchmark for... When assessing the HEMP radiation environment and the conducted transient disturbances it generates on power, antenna, I/O signal lines, and control lines. The performance of electrical and electronic equipment.
---Part 27: Three-phase voltage imbalance immunity test. The purpose is to test the immunity of electrical and electronic equipment to unbalanced power supplies.
A reference is established for evaluating immunity to disturbances under pressure.
---Part 28: Power Frequency Variation Immunity Test. The purpose is to assess the immunity of electrical and electronic equipment to variations in power frequency. It provides a basis for immunity evaluation.
---Part 29: Immunity testing for DC power supply input port voltage sags, short interruptions, and voltage variations. The purpose is to establish... A general criterion for evaluating the immunity of DC electrical and electronic equipment to voltage dips, short interruptions and voltage changes.
---Part 30: Power Quality Measurement Methods. The purpose is to specify the methods for measuring power quality parameters in 50Hz AC power supply systems. And the interpretation of the measurement results.
---Part 31: Broadband Conducted Disturbance Immunity Testing at AC Power Ports. The aim is to establish a common benchmark for evaluating electrical... Immunity of AC power ports of electronic devices to conducted interference from intentional and/or unintentional broadband signal sources.
---Part 32: Overview of High Altitude Nuclear Electromagnetic Pulse (HEMP) Simulators. The aim is to provide an overview of existing international system-level simulators.
HEMP simulators and related information needed when they are used as immunity testing and verification devices.
---Part 33: Measurement Methods for High-Power Transient Parameters. The aim is to provide methods for measuring the waveforms of high-power electromagnetic transient responses. Information about the feature parameters.
---Part 34: Immunity tests for voltage dips, short interruptions and voltage variations of equipment with a main power supply phase current greater than 16A.
The aim is to establish a universal standard for evaluating the immunity of electrical and electronic equipment to voltage dips, short-term interruptions, and voltage variations. Guidelines.
---Part 35: Overview of High Power Electromagnetic (HPEM) Simulators. The aim is to provide an overview of existing international system-level HPEM simulators.
Bandwidth (narrowband) and broadband (wideband, sub-ultrawideband, and ultrawideband) simulators and their use as immunity testing and verification equipment The required information.
---Part 36: Intentional Electromagnetic Interference Immunity Testing for Equipment and Systems. The purpose is to assess the immunity of equipment and systems to intentional electromagnetic interference.
The immunity of interference sources provides a method for determining the test level.
---Part 37: Calibration and Verification Protocol for Harmonic Emission Compliance Testing Systems. The purpose is to provide a calibration and verification protocol for manufacturers, end-users, and independent testing institutions.
Laboratories and other organizations provide systematic guidance to define the applicable compliance status within a certain harmonic current emission range.
---Part 38: Test, Validation, and Calibration Protocol for Voltage Fluctuation and Flicker Compliance Test Systems. The purpose is to provide a basis for type testing... The system of equipment provides guidelines and methods for regular calibration and verification.
---Part 39: Near-Range Radiation Field Immunity Testing. The aim is to establish a universal benchmark for evaluating exposure to near-range sources.
Immunity requirements for electrical and electronic equipment in radiated radio frequency electromagnetic fields.
---Part 40: Digital Methods for Measuring Electrical Quantities of Modulated or Distorted Signals. The aim is to introduce two methods applicable to fluctuating or non-periodic signals.
A digital algorithm for measuring electrical quantities under load is presented, and the working principle of the proposed algorithm is explained.
---Part 41: Broadband Radiated Immunity Testing. The purpose is to evaluate the immunity of electrical and electronic equipment to broadband radiated electromagnetic fields. Deflection establishes a universal benchmark.
1 Scope
This document specifies the immunity requirements, test methods, and recommended tests for equipment subjected to pulsed magnetic field disturbances primarily from the following locations. Level range.
---Industrial facilities;
---power plant;
---Railway facilities;
---Medium and high voltage substations.
The applicability of this document to devices installed in different locations is determined by the phenomena described in Chapter 4.
This document does not consider interference caused by capacitive and inductive coupling in cables or other parts of field facilities. Related conduction... Harassment is considered in other standards.
The purpose of this document is to establish a general standard for evaluating the immunity of electrical and electronic equipment to pulsed magnetic fields. This document specifies... The test method describes a consistent approach for evaluating the immunity of a device or system to defined electromagnetic phenomena.
Note: As described in GB /Z 18509, this document is a basic EMC standard for use by product technical committees. As stated in GB /Z 18509, products... The technical committee is responsible for determining whether to adopt this immunity standard, and if so, for determining the appropriate test levels and performance criteria to evaluate its performance. Special immunity requirements for products. This document stipulates that.
---Range of test levels;
---Test equipment;
---Experimental configuration;
---Experimental procedure.
The purpose of laboratory testing is to determine the effect of the device under test (EUT) on pulsed magnetic fields induced by switching and lightning effects under specified operating conditions. The reaction.
2 Normative references
The contents of the following documents, through normative references within the text, constitute essential provisions of this document. Dated citations are not included.
For references to documents, only the version corresponding to that date applies to this document; for undated references, the latest version (including all amendments) applies. This document.
Note: GB/T 2900.77-2008 Electrical Terminology - Electrical and Electronic Measurements and Instruments - Part 1: General Terms for Measurement (IEC 60050-311. 2001, IDT);
GB/T 4365-2024 Electrotechnical Terminology Electromagnetic Compatibility (IEC 60050-161:2021, MOD).
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 46 pages — is available in the English PDF.
Referenced standards
Normative references
Cited by
- GB/T 21714.4-2026Protection against lightning - Part 4: Electrical and electronic systems within structures
- GB/T 22390.5-2026Control and protection equipment of high-voltage direct current (HVDC) transmission systems - Part 5: DC line fault location devices
- GB/T 22390.6-2026Control and protection equipment of high-voltage direct current (HVDC) transmission systems - Part 6: Converter station transient fault oscillograph devices
- GB/T 47832-2026General specification for integrated motor protection devices
- GB/T 18037-2025Basic technical requirements and design guidelines for live working tools, equipment and devices
- GB/T 26862-2025Test specifications of synchrophasor measurement device for power systems
How to Download GB/T 17626.9-2025
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 4365-2024 — Electrotechnical terminology-Electromagnetic compatibility
GB/T 17626.1-2006 — [Replaced by GB/Z 17626.1-2024] Electromagnetic compatibility -- Testing and measurement techniques -- Overview of immunity tests
GB/T 17626.10-2017 — Electromagnetic compatibility -- Testing and measurement techniques -- Damped oscillatory magnetic field immunity test
Secure payment via Stripe
Payments accepted
GB/T 17626.9-2025