GB/T 42150.1-2022Test specification for on-site protection equipment—Part 1: General part (English PDF)
就地化继电保护装置检测规范 第1部分:通用部分
This is a limited preview
Buy now to download the full PDF (18 pages)
Need quotation for your management?
Get a formal quotation for GB/T 42150.1-2022 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
December 30, 2022
Implementation date
July 1, 2023
Scope
GB/T 42150.1-2022 is the English-translated version of 就地化继电保护装置检测规范 第1部分:通用部分.
GB/T 42150.1-2022 is the general part of the Chinese detection specification for in-situ relay protection devices, and it fixes the common inspection items, inspection content, test methods and the judgment of test results.
It sets the detection conditions - test environment, benchmark conditions and testing equipment - and then the inspection and test items: structural and visual inspection, insulation, overload capability, power, protective bonding impedance and contact performance tests, climate environment tests, DC supply influence, mechanical performance, electromagnetic compatibility and device reliability, with informative annexes on the VFTO impact test and the reliability test.
It applies to the type test of devices of 110 kV and below, with factory joint commissioning and on-site commissioning referring to it. Its introduction states that GB/T 42150 is planned in seven parts. Issued on 30 December 2022, it has applied since 1 July 2023.
Found what you need?
Document preview — GB/T 42150.1-2022
National Standard of the People's Republic of China
- ICS
- 29.240
- Classification
- K 45
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Preface
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 Detection condition
- 4.1 Environmental conditions for testing
- 4.2 Benchmark conditions for detection
- 4.3 Testing equipment
- 5 Inspection and testing
- 5.1 Structural and visual inspection
- 5.2 Insulation test
- 5.3 Overload capability test
- 5.4 Power Test
- 5.5 Protective bonding impedance test
- 5.6 Contact performance test
- 5.7 Climate environment test
- 5.8 DC power supply influence test
- 5.9 Mechanical performance test
- 5.10 Electromagnetic compatibility test
- 5.11 Device reliability test
- Appendix A (informative) VFTO impact test of in-situ protection device
- Appendix B (Informative) Reliability Test of In-situ Protective Devices
Foreword
This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1: Structure and Drafting Rules for Standardization Documents" drafting.
This document is the first part of GB/T 42150 "Testing Specifications for In-situ Relay Protection Devices". GB/T 42150 has been issued with Lower part.
--- Part 1: General part.
Introduction
With the improvement of relay protection requirements and technological progress, in-situ relay protection devices installed without protection have emerged as the times require, becoming a new One of the development directions of the first generation relay protection. In order to cooperate with the application of on-site relay protection devices, it is urgent to formulate corresponding testing standards and regulations.
Standardize the testing items, testing methods, etc., guide the design, manufacture, operation and maintenance and commissioning of substation devices, and effectively ensure the safety and stability of key power grid projects run.
GB/T 42150 "Testing Specifications for In-situ Relay Protection Devices" is proposed to be composed of seven parts.
--- Part 1: General part. The purpose is to standardize the general inspection items, inspection contents, and testing methods of on-site relay protection devices. Judgment of law and test results.
--- Part 2: Connectors and prefabricated cables. The purpose is to standardize the inspection items, inspection Test content, test method and test result judgment.
--- Part 3: Special functions of the local operation box. The purpose is to standardize the inspection items of the local operation box for the local relay protection device The purpose, test content, test method and judgment of test results.
--- Part 4: Special functions of the intelligent management unit. The purpose is to standardize the inspection of intelligent management units for in-situ relay protection devices.
Test items, test content, test methods and judgment of test results.
--- Part 5: Special functions of line protection devices. The purpose is to standardize the inspection items and inspection contents of in-situ line protection devices. Judgment of content, test methods and test results.
--- Part 6: Special functions of bus protection devices. The purpose is to standardize the inspection items, Inspection content, test method and judgment of test results.
--- Part 7: Special functions of transformer protection devices. The purpose is to standardize the inspection of special functions of in-situ transformer protection devices Judgment of items, test contents, test methods and test results.
1 Scope
This document specifies the general inspection items, inspection content, Test methods and judgment of test results.
This document is applicable to the type test of in-situ relay protection devices (hereinafter referred to as "device") with a voltage level of 110kV and below.
The factory joint commissioning and on-site commissioning of in-situ relay protection devices shall be implemented as a reference.
2 Normative references
The contents of the following documents constitute the essential provisions of this document through normative references in the text. Among them, dated references For documents, only the version corresponding to the date is applicable to this document; for undated reference documents, the latest version (including all amendments) is applicable to this document.
GB/T 2423.17-2008 Environmental testing for electrical and electronic products - Part 2: Test method Test Ka. Salt spray
GB/T 2423.22-2012 Environmental testing - Part 2: Test methods Test N. Temperature change
GB/T 2423.24-2013 Environmental testing Part 2: Test method Test Sa. Simulation of solar radiation on the ground and its test test guideline
GB/T 4208-2017 Enclosure protection level (IP code)
GB/T 7261-2016 Basic test methods for protective relays and automatic safety devices
GB/T 11287-2000 Electrical relays Part 21: Measuring vibrations, shocks, bumps and earthquakes of relays and protective devices Test part 1.Vibration test (sinusoidal)
GB/T 14537-1993 Measuring relays and protective devices shock and bump test
GB/T 14598.2 Measuring relays and protective devices - Part 1: General requirements
GB/T 14598.26-2015 Measuring relays and protective devices - Part 26: Requirements for electromagnetic compatibility
GB/T 17626.3-2016 Electromagnetic Compatibility Test and Measurement Technology Radio Frequency Electromagnetic Field Radiation Immunity Test
GB/T 17626.9 Electromagnetic Compatibility Test and Measurement Technology Pulse Magnetic Field Immunity Test
GB/T 17626.10-2017 Electromagnetic Compatibility Test and Measurement Technology Damped Oscillating Magnetic Field Immunity Test
GB/T 17626.18 Electromagnetic Compatibility Test and Measurement Technology Damped Oscillatory Wave Immunity Test
GB/T 40096.1 Technical specifications for in-situ protective relays Part 1: General technical requirements
DL/T 478-2013 General Technical Conditions for Relay Protection and Safety Automatic Devices
3 Terms and Definitions
The following terms and definitions defined in GB/T 7261-2016, GB/T 40096.1 and DL/T 478-2013 apply to this document.
3.1 During
the routine operation and ground fault of gas-insulated metal-enclosed switchgear, a traveling wave with a very steep wave head is generated.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 18 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 2423.17-2008Environmental testing - Part 2: Test methods - Test Ka: Salt mist
- GB/T 2423.22-2012Environmental testing - Part 2: Test methods - Test N: Change of temperature
- GB/T 2423.24-2013Environmental testing—Part 2: Test methods—Test S: Simulated solar radiation at ground level and guidance for solar radiation testing and weathering
- GB/T 4208-2017Degrees of protection provided by enclosures (IP code)
- GB/T 7261-2016Basic test methods for protection relays and security automatic equipment
- GB/T 11287-2000Electrical relays. Part 21: Vibration, shock, bump and seismic tests on measuring relays and protection equipment. Section one: Vibration tests (sinusoidal)
DL/T 478-2013
Similar standards
How to Download GB/T 42150.1-2022
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 11287-2000 — Electrical relays. Part 21: Vibration, shock, bump and seismic tests on measuring relays and protection equipment. Section one: Vibration tests (sinusoidal)
GB/T 14537-1993 — Shock and bump tests on measuring relays and protection equipment
GB/T 14598.2-2025 — Measuring relays and protection equipment - Part 1: Common requirements