Valid

GB/T 40096.4-2021Technical specification for on-site protection equipment—Part 4: Smart management unit (English PDF)

就地化继电保护装置技术规范 第4部分:智能管理单元

Preview PDF

This is a limited preview

Buy now to download the full PDF (35 pages)

Need quotation for your management?

Get a formal quotation for GB/T 40096.4-2021 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

May 21, 2021

Implementation date

December 1, 2021

Scope

GB/T 40096.4-2021 is the English-translated version of 就地化继电保护装置技术规范 第4部分:智能管理单元.

GB/T 40096.4-2021 is the Chinese standard "Technical specification for on-site protection equipment—Part 4: Smart management unit".

Its scope clause reads: This part of GB/T 40096 specifies the in-situ relay protection intelligent management unit for voltage levels of 110kV and below (hereinafter referred to as smart Capable of management unit) technical requirements, test methods, inspection rules and requirements for signs, packaging, transportation, storage, etc. This part is applicable to the research of the in-situ relay protection intelligent management unit (hereinafter referred to as the intelligent management unit) for voltage levels of 110kV and below System, design, manufacture, test, inspection and application. Its clauses include terms and definitions.

Found what you need?

Document preview — GB/T 40096.4-2021

National Standard of the People's Republic of China

ICS
29.240
Classification
K 45

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Technical requirements
  • 4.1 Environmental conditions
  • 4.2 Rated electrical parameters
  • 4.3 General requirements
  • 4.4 Technical Principle
  • 4.5 Basic functional requirements
  • 4.6 Requirements for advanced features
  • 4.7 Power consumption
  • 4.8 Insulation requirements
  • 4.9 Humidity and heat resistance
  • 4.10 Mechanical properties
  • 4.11 Electromagnetic compatibility performance
  • 4.12 Continuous power-on
  • 4.13 Structure and appearance
  • 4.14 Safety requirements
  • 4.15 Functional performance
  • 5 Test method
  • 5.1 Test conditions
  • 5.2 Environmental impact test
  • 5.3 Power influence test
  • 5.4 Device function and performance test
  • 5.5 Power consumption test
  • 5.6 Insulation performance test
  • 5.7 Humidity and heat resistance test
  • 5.8 Mechanical performance test
  • 5.9 Electromagnetic compatibility performance test
  • 5.10 Continuous power-on test
  • 5.11 Communication interface test
  • 5.12 Structural and visual inspection
  • 5.13 Safety requirements test
  • 6 Inspection rules
  • 6.1 Inspection classification
  • 6.2 Factory inspection
  • 6.3 Type inspection
  • 7 Marking, packaging, transportation and storage
  • 7.1 Sign
  • 7.2 Packaging
  • 7.3 Transportation
  • 7.4 Storage
  • 8 other
  • 8.1 Product accompanying documents
  • 8.2 Device design life index
  • 8.3 Quality assurance period
  • Appendix A (informative appendix) Agent communication mode of intelligent management unit
  • Appendix B (informative appendix) Intelligent management unit modeling requirements
  • Appendix C (informative appendix) Intelligent management unit network structure
  • Appendix D (normative appendix) Operation log
  • Appendix E (informative appendix) Inspection report format
  • Appendix F (informative appendix) Process level automatic configuration rules
  • Appendix G (Normative Appendix) Intelligent Management Unit Detection Method

1 Scope

This part of GB/T 40096 specifies the in-situ relay protection intelligent management unit for voltage levels of 110kV and below (hereinafter referred to as smart

Capable of management unit) technical requirements, test methods, inspection rules and requirements for signs, packaging, transportation, storage, etc.

This part is applicable to the research of the in-situ relay protection intelligent management unit (hereinafter referred to as the intelligent management unit) for voltage levels of 110kV and below

System, design, manufacture, test, inspection and application.

2 Normative references

The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this article

Pieces. For undated reference documents, the latest version (including all amendments) is applicable to this document.

GB/T 191 Packaging, storage and transportation pictorial signs

GB/T 2887-2011 General Specification for Computer Site

GB/T 4798.2 Environmental conditions for the application of electrical and electronic products Part 2.Transportation

GB/T 7261-2016 Basic test methods for relay protection and safety automatic devices

GB/T 11287-2000 Electrical Relay Part 21.Measuring the vibration, shock, collision and earthquake of relays and protection devices

Test Part 1.Vibration Test (Sine)

GB/T 13384 General technical conditions for packaging of mechanical and electrical products

GB/T 14537-1993 Impact and collision test of measuring relays and protection devices

GB/T 14598.2-2011 Measuring Relays and Protection Devices Part 1.General Requirements

GB/T 14598.3-2006 Electrical Relay Part 5.Insulation coordination requirements and tests for measuring relays and protection devices

GB/T 14598.26-2015 Measuring Relays and Protection Devices Part 26.Electromagnetic Compatibility Requirements

GB/T 14598.27-2017 Measuring Relays and Protection Devices Part 27.Product Safety Requirements

GB/T 17626.9-2011 Electromagnetic compatibility test and measurement technology Pulse magnetic field immunity test

GB/T 17626.10-2017 Electromagnetic compatibility test and measurement technology Damped oscillation magnetic field immunity test

GB/T 40096.1 Technical specification for in-situ protection relay devices Part 1.General technical conditions

DL/T 478-2013 General technical requirements for relay protection and safety automatic devices

DL/T 860 (all parts) Power automation communication network and system

DL/T 1455-2015 Power system control software safety and its evaluation technical requirements

DL/T 1782-2017 Information Specification for Substation Relay Protection

3 Terms and definitions

The terms and definitions defined in DL/T 860 (all parts) and GB/T 40096.1 apply to this document.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 35 pages — is available in the English PDF.

Referenced standards

Normative references

GB/T 14598.3-2006 · DL/T 478-2013 · DL/T 860

Similar standards

How to Download GB/T 40096.4-2021

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
35 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 40096.4-2021