GB/T 38844-2020Smart factory—General specification for time synchronization, time management and test in industry automation system (English PDF)
智能工厂 工业自动化系统时钟同步、管理与测量通用规范
This is a limited preview
Buy now to download the full PDF (17 pages)
Need quotation for your management?
Get a formal quotation for GB/T 38844-2020 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
June 2, 2020
Implementation date
January 1, 2021
Scope
GB/T 38844-2020 is the English-translated version of 智能工厂 工业自动化系统时钟同步、管理与测量通用规范.
GB/T 38844-2020 is the Chinese standard "Smart factory—General specification for time synchronization, time management and test in industry automation system".
Its scope clause reads: This standard specifies the basic composition, configuration and networking principles of the clock synchronization system for smart factories and industrial automation systems.
It describes the terms, definitions, functions, requirements of clock synchronization systems, and the methods of clock synchronization system management. It also specifies the clock synchronization system Requirements for measurement test conditions, measurement items, measurement methods, measurement targets and measurement cycles.
This standard applies to working on the basic reference model of open system interconnection specified in GB/T 9387.1 layer 1 ~ layer 2 or layer 1 ~ layer 3, And the physical layer complies with IEEE802.3 specifications, the data link layer complies with IEEE802.1D and GB/T 15629.2 specifications, and the network layer complies with Industrial Ethernet switch specified by the Internet Engineering Task Force (IETF) IP protocol cluster. Its clauses include terms, definitions and abbreviations.
Found what you need?
Document preview — GB/T 38844-2020
National Standard of the People's Republic of China
- ICS
- 25.040
- Classification
- N 10
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms, definitions and abbreviations
- 3.1 Terms and definitions
- 3.2 Acronyms
- 4 Network
- 4.1 Smart Factory Network
- 4.2 Smart factory clock synchronization networking
- 5 Clock synchronization
- 5.1 Clock synchronization system
- 5.2 Technical requirements
- 5.3 Performance requirements
- 5.4 Environmental test requirements
- 6 Clock Management
- 6.1 Overview
- 6.2 Technical requirements
- 6.3 Master Clock and Slave Clock Self-Test Status Information
- 6.4 Time synchronization monitoring of clock synchronization equipment and timed equipment
- 7 Clock measurement
- 7.1 Overview
- 7.2 Measuring equipment and requirements
- 7.3 Measurement content and requirements
1 Scope
This standard specifies the basic composition, configuration and networking principles of the clock synchronization system for smart factories and industrial automation systems.
It describes the terms, definitions, functions, requirements of clock synchronization systems, and the methods of clock synchronization system management. It also specifies the clock synchronization system
Requirements for measurement test conditions, measurement items, measurement methods, measurement targets and measurement cycles.
This standard applies to working on the basic reference model of open system interconnection specified in GB/T 9387.1 layer 1 ~ layer 2 or layer 1 ~ layer 3,
And the physical layer complies with IEEE802.3 specifications, the data link layer complies with IEEE802.1D and GB/T 15629.2 specifications, and the network layer complies with
Industrial Ethernet switch specified by the Internet Engineering Task Force (IETF) IP protocol cluster.
2 Normative references
The following documents are essential for the application of this document. For dated reference documents, only the dated version applies to this article
Pieces. For the cited documents without date, the latest version (including all amendments) applies to this document.
GB/T 6107 Interface between data terminal equipment and data circuit termination equipment using serial binary data exchange
GB/T 9387.1 Basic reference model for open system interconnection of information technology Part 1.Basic model
GB/T 13729-2019 Telecontrol terminal equipment
GB/T 15629.2 Particular requirements for local area network and metropolitan area network for remote communication and information exchange between information technology systems Part 2
Points. logical link control
GB/T 17626.2-2018 Electromagnetic Compatibility Test and Measurement Technology Electrostatic Discharge Immunity Test
GB/T 17626.3-2016 Electromagnetic compatibility test and measurement technology RF electromagnetic field radiation immunity test
GB/T 17626.4-2018 Electromagnetic compatibility test and measurement technology Electrical fast transient pulse group immunity test
GB/T 17626.5-2019 EMC test and measurement technology surge (shock) immunity test
GB/T 17626.8-2006 EMC test and measurement technology power frequency magnetic field immunity test
GB/T 17626.9-2011 electromagnetic compatibility test and measurement technology pulse magnetic field immunity test
GB/T 17626.10-2017 Electromagnetic compatibility test and measurement technology Damped oscillating magnetic field immunity test
Accurate clock synchronization protocol of GB/T 25931 network measurement and control system
IEEE802.1D IEEE local area network and metropolitan area network standard medium access control (MAC) bridge [IEEEStandardforLocal andmetropolitanareanetworks.MediaAccessControl(MAC)Bridges]
IEEE802.3 IEEE Information Technology Standard Specific Requirements for Local Area Networks and Metropolitan Area Networks Part 3.Carrier Detection with Collision Detection
Listening to multiple access methods and physical layer specifications [IEEEStandardforInformationtechnology-Localandmetropolitan areanetworks-Specificrequirements-Part 3.CarrierSenseMultipleAccesswithColisionDetection (CSMA/CD)AccessMethodandPhysicalLayerSpecifications]
IRIGStandard200-04 IRIG serial clock code format (IRIGSerialTimeCodeFormats)
3 Terms, definitions and abbreviations
3.1 Terms and definitions
The following terms and definitions apply to this document.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 6107Interface between data terminal equipment and data circuit termination equipment employing serial binary data interchange
- GB/T 9387.1Information technology. Open Systems Interconnection. Basic Reference Model. Part 1: The Basic Model
- GB/T 13729-2019Remote terminal unit equipment
- GB/T 15629.2Information technology -- Telecommunications and information exchange between systems -- Local and metropolitan area networks -- Specific requirements -- Part 2: Logical link control
- GB/T 17626.2-2018Electromagnetic compatibility -- Testing and measurement techniques -- Electrostatic discharge immunity test
- GB/T 17626.3-2016Electromagnetic compatibility - Testing and measurement techniques - Part 3: Radiated, radio-frequency, electromagnetic field immunity test
Similar standards
How to Download GB/T 38844-2020
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 13729-2019 — Remote terminal unit equipment
GB/T 15629.2-2008 — Information technology -- Telecommunications and information exchange between systems -- Local and metropolitan area networks -- Specific requirements -- Part 2: Logical link control
GB/T 17626.10-2017 — Electromagnetic compatibility -- Testing and measurement techniques -- Damped oscillatory magnetic field immunity test
Secure payment via Stripe
Payments accepted
GB/T 38844-2020
$270.00