GB/T 29327-2023Requirements for 1000kV reactor protection equipment (English PDF)
1000kV电抗器保护装置技术要求
This is a limited preview
Buy now to download the full PDF (17 pages)
Need quotation for your management?
Get a formal quotation for GB/T 29327-2023 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
August 6, 2023
Implementation date
March 1, 2024
Scope
GB/T 29327-2023 is the English-translated version of 1000kV电抗器保护装置技术要求.
GB/T 29327-2023 is the Chinese standard "Requirements for 1000kV reactor protection equipment". Its scope clause reads: This document stipulates the basic technical requirements, test methods, inspection rules and marking, packaging and transportation requirements for 1000kV reactor protection devices.
Transmission and storage requirements. This document is applicable to 1000kV reactor protection devices, including fixed capacity shunt reactor protection devices and hierarchical controllable parallel reactors.
Reactor protection device (hereinafter referred to as "device"), as the basis for the design, manufacture, inspection and application of such devices. Its clauses include normative reference documents; terms and definitions.
Found what you need?
Document preview — GB/T 29327-2023
National Standard of the People's Republic of China
- ICS
- 29.240.99
- Classification
- K 45
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Preface
- 1 Scope
- 2 Normative reference documents
- 3 Terms and Definitions
- 4 Technical requirements
- 4.1 Climate environment requirements
- 4.2 Rated electrical parameters
- 4.3 Power consumption
- 4.4 General functional requirements
- 4.5 Technical performance requirements
- 4.6 Overload capacity
- 4.7 Insulation performance
- 4.8 Humidity and heat resistance
- 4.9 Electromagnetic compatibility requirements
- 4.10 Dynamic simulation
- 4.11 Continuous power on
- 4.12 Mechanical properties
- 4.13 Structure, appearance and others
- 5 Test methods
- 5.1 Test preparation
- 5.2 Technical performance test
- 5.3 Dynamic simulation test
- 5.4 Operating temperature test
- 5.5 Storage temperature test
- 5.6 Power consumption test
- 5.7 Overload capacity test
- 5.8 Insulation test
- 5.9 Damp heat test
- 5.10 Electromagnetic compatibility requirements test
- 5.11 Test on the impact of power supply changes on performance
- 5.12 Continuous power test
- 5.13 Mechanical performance test
- 5.14 Structural and appearance inspection
- 6 Inspection Rules
- 6.1 Inspection classification
- 6.2 Factory inspection
- 6.3 Type test
- 6.4 Qualification determination
- 7 Marking, packaging, transportation and storage
- 7.1 Flag
- 7.2 Packaging
- 7.3 Transport
- 7.4 Storage
- 8 other
- 8.1 Documents and objects accompanying the product when leaving the factory
- 8.2 Quality Assurance
- Appendix A (informative) Typical protection configuration of 1000kV fixed capacity shunt reactor
- Appendix B (informative) Typical protection configuration of 1000kV hierarchical controllable shunt reactor
1 Scope
This document stipulates the basic technical requirements, test methods, inspection rules and marking, packaging and transportation requirements for 1000kV reactor protection devices.
Transmission and storage requirements.
This document is applicable to 1000kV reactor protection devices, including fixed capacity shunt reactor protection devices and hierarchical controllable parallel reactors.
Reactor protection device (hereinafter referred to as "device"), as the basis for the design, manufacture, inspection and application of such devices.
2 Normative reference documents
The contents of the following documents constitute essential provisions of this document through normative references in the text. Among them, the dated quotations
For undated referenced documents, only the version corresponding to that date applies to this document; for undated referenced documents, the latest version (including all amendments) applies to this document.
GB/T 191 Packaging, storage and transportation pictorial mark
GB/T 2887-2011 General specifications for computer sites
GB/T 2900.17 Electrical terminology measuring relay
GB/T 2900.49 Electrical terminology power system protection
GB/T 4798.2 Environmental condition classification Environmental parameter group classification and severity classification Part 2.Transportation and loading and unloading
GB/T 7261-2016 Basic test methods for relay protection and safety automatic devices
GB/T 9361-2011 Computer site safety requirements
GB/T 11287-2000 Electrical relays Part 21.Measuring vibration, shock, collision and earthquake of relays and protective devices
Test Part 1.Vibration Test (Sine)
GB/T 13384 General technical conditions for mechanical and electrical product packaging
GB/T 14537-1993 Impact and collision test of measuring relays and protective devices
GB/T 14598.2-2011 Measuring relays and protective devices Part 1.General requirements
GB/T 14598.26-2015 Measuring relays and protective devices Part 26.Electromagnetic compatibility requirements
GB/T 14598.27-2017 Measuring relays and protective devices Part 27.Product safety requirements
GB/T 17626.9-2011 Electromagnetic compatibility testing and measurement technology pulse magnetic field immunity test
GB/T 17626.10-2017 Electromagnetic compatibility test and measurement technology damped oscillating magnetic field immunity test
GB/T 19520.12-2009 Electronic equipment mechanical structure 482.6mm (19in) series mechanical structure dimensions Part 3-101
Sub. plug-in box and its plug-ins
GB/T 26864-2011 Dynamic model test of relay protection products for power systems
DL/T 242-2012 General technical conditions for high voltage shunt reactor protection devices
DL/T 478-2013 General technical conditions for relay protection and safety automatic devices
DL/T 860 (all parts) Power automation communication networks and systems
NB/T 10680-2021 Technical Guidelines for Information Security of Relay Protection and Safety Automatic Devices
3 Terms and definitions
The terms and definitions defined in GB/T 2900.17, GB/T 2900.49, GB/T 14598.2-2011, DL/T 242-2012 apply to this document.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 191Graphical symbols marking for handling and storage of packages
- GB/T 2887-2011General specification for computer field
- GB/T 2900.17Electrotechnical terminology - Measuring relays and protection equipment
- GB/T 2900.49Electrotechnical terminology -- Power system protection
- GB/T 4798.2Classification of environmental conditions - Classification of groups of environmental parameters and their severities - Part 2: Transportation and handling
- GB/T 7261-2016Basic test methods for protection relays and security automatic equipment
DL/T 478-2013 · DL/T 860
Similar standards
How to Download GB/T 29327-2023
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
DL/T 242-2012 — General specification for high-voltage shunt reactor protection equipment
DL/T 860.10-2018 — Communication networks and systems for power utility automation -Part 10: Conformance testing
DL/T 860.3-2004 — Communication networks and systems in substations. Part 3: General requirements