GB/T 26864-2011The dynamic test of the power system protective products (English PDF)

电力系统继电保护产品动模试验

Preview PDF

This is a limited preview

Buy now to download the full PDF (26 pages)

Need quotation for your management?

Get a formal quotation for GB/T 26864-2011 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

July 29, 2011

Implementation date

December 1, 2011

Scope

GB/T 26864-2011 is the English-translated version of 电力系统继电保护产品动模试验.

GB/T 26864-2011 is the Chinese standard "The dynamic test of the power system protective products".

Its scope clause reads: This standard specifies the relay 110kV and above voltage level, 100MW and above generating units of the relay protection products and DC transmission Electric system of the converter transformer and AC filter protection product dynamic test of the typical wiring, fault simulation and dynamic simulation test system (Hereinafter referred to as dynamic mode) the basic requirements, as the exchange of 110kV and above voltage level, 100MW and above generating units of the relay Protection products and DC transmission system protection products for power system dynamic simulation test basis.

This standard applies to 110kV and above AC voltage level, 100MW and above generating units of the relay protection products and DC transmission Dynamic protection test of electric system.

110kV below the voltage level and below 100MW generating units of the relay protection products dynamic mode Test can refer to this standard. Its clauses include normative reference documents.

Found what you need?

Document preview — GB/T 26864-2011

National Standard of the People's Republic of China

ICS
29.120.50
Classification
K 45

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • 3.1 Simulation system performance requirements
  • 3.2 Fault simulation
  • 3.3 Simulation of instability phenomenon
  • 3.4 Other requirements
  • 3.5 auxiliary power supply
  • 4 analog element
  • 4.1 infinity power supply
  • 4.2 AC line
  • 4.3 Power plants and analog generators
  • 4.4 Transformer
  • 4.5 parallel reactor
  • 4.6 circuit breaker
  • 4.7 Transition resistance
  • 4.8 Series Compensation Capacitor
  • 4.9 Current Transformer
  • 4.10 voltage transformer
  • 4.11 DC transmission system
  • 5 line protection
  • 5.1 Typical wiring method for line protection test and basic requirements for model
  • 5.2 Test items for line protection products
  • 6 bus protection products
  • 6.1 Typical wiring of busbar protection test and basic requirements for model
  • 6.2 Test items for bus protection products
  • 7 Transformer protection products
  • 7.2 Test items for transformer protection products
  • 8 parallel reactor protection products
  • 8.2 Test items for parallel reactor protection products
  • 9 Generator Protection and Generator Transformer Group Protection Products
  • 9.1 Typical Wiring Methods for Generator and Generator Protection Tests and Basic Requirements for Models
  • 10 DC transmission system protection
  • 10.1 Dynamic mode test typical wiring method
  • 10.3 Test of converter transformer protection products
  • 10.4 AC filter protection

1 Scope

This standard specifies the relay 110kV and above voltage level, 100MW and above generating units of the relay protection products and DC transmission

Electric system of the converter transformer and AC filter protection product dynamic test of the typical wiring, fault simulation and dynamic simulation test system (Hereinafter referred to as dynamic mode) the basic requirements, as the exchange of 110kV and above voltage level, 100MW and above generating units of the relay

Protection products and DC transmission system protection products for power system dynamic simulation test basis.

This standard applies to 110kV and above AC voltage level, 100MW and above generating units of the relay protection products and DC transmission

Dynamic protection test of electric system. 110kV below the voltage level and below 100MW generating units of the relay protection products dynamic mode

Test can refer to this standard.

2 normative reference documents

The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article

Pieces. For undated references, the latest edition (including all amendments) applies to this document.

GB/T 4703 Capacitive Voltage Transformer (IEC 60044-5..2004, MOD)

GB/T 15145 General technical conditions for transmission line protection devices

GB/T 16847 Technical requirements for transient characteristics of current transformers for protection (idtIEC 60044-6..1992)

GB/T 20840.7 Transformers - Part 7. Electronic voltage transformers (IEC 60044-7..1999, MOD)

GB/T 20840.8 Transformers - Part 8. Electronic current transformers (IEC 60044-8..2002, MOD)

GB/T 22390.4 HVDC transmission system control and protection equipment - Part 4. DC system protection equipment

General specification for DL/T 670 microcomputer bus protection device

General specification for protection devices of transformer units of DL/T 671 microcomputer generator

General specification for DL/T 770 microcomputer transformer protection device

Basic Requirements for Dynamic Test System

3.1 Simulation system performance requirements

3.1.1

In the simulated transmission capacity, the current value of the test product is close to the current value of the prototype system, and the difference

Not more than 10%. The secondary rated AC voltage of the analog system to the test product should be the same as that of the prototype system.

3.1.2

The secondary current value of the high voltage side busbar short circuit of the power plant shall not exceed 20% before the prototyping.

3.1.3

The short-circuit current secondary value through the analog line should correspond to the value calculated from the actual parameters of the analog system.

3.1.4

If there is no special requirement, the maximum short circuit current value of the simulation system can be considered according to the maximum short circuit capacity of the prototype system.

3.1.5

connected to the parallel reactor analog line, in the case of full voltage, the power side of the circuit breaker is disconnected, the residual voltage on the line

The transient low frequency component, the voltage decay to zero time is not less than 1s.

3.1.6

in the analog system wiring and operation should be representative of the way, in addition to the test products can be tested the general technical performance, but also

Should be able to assess the tested products in the edge of the technical performance.

3.2 fault simulation

The dynamic simulation system should be able to.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 26 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 26864-2011

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
26 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 26864-2011

$465.00