GB/T 40532-2021Guide on technology for power system substation-area circuit breaker failure (dead-zone) protection (English PDF)
电力系统站域失灵(死区)保护技术导则
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 40532-2021 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
October 11, 2021
Implementation date
May 1, 2022
Scope
GB/T 40532-2021 is the English-translated version of 电力系统站域失灵(死区)保护技术导则.
GB/T 40532-2021 is a technical guide for substation-area circuit breaker failure (dead-zone) protection in power systems, a station-level scheme that collects analogue and switch signals from all bays of a station and exchanges them over fibre channels, so that a breaker failure or dead-zone fault can be isolated faster than conventional protection allows.
It gives the general requirements, the functions and configuration of the protection, its technical requirements, the requirements for auxiliary equipment and secondary circuits, and the tests, with a normative annex on information exchange and an informative annex on the protection framework.
It applies to power plants and substations with double-breaker arrangements such as the 3/2 breaker scheme, and other layouts may refer to it. Grid operators and protection equipment makers use it. It was issued on 11 October 2021 and has applied since 1 May 2022.
Found what you need?
Document preview — GB/T 40532-2021
National Standard of the People's Republic of China
- ICS
- 29.240
- Classification
- F 21
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 General requirements
- 5 Function and configuration
- 6 Technical requirements
- 7 Requirements for auxiliary equipment and secondary circuits
- 8 Experiment
- Appendix A (Normative) Information Interaction Specification
- Appendix B (informative) Site failure (dead zone) protection framework
Foreword
This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1: Structure and Drafting Rules of Standardization Documents" Drafting.
Introduction
As large-capacity UHV DC transmission projects are put into operation one after another, the interconnection between regional power grids is becoming closer, AC and DC, transmission and receiving end, upper and lower power grids The electromagnetic coupling between them has been continuously enhanced, and the characteristics of system integration have become increasingly prominent. When a circuit breaker failure (dead zone) fault occurs in the UHV DC receiving end power grid, If the fault cannot be removed in time, it will cause the UHV DC continuous commutation failure in severe cases, which will bring great impact to the safe and stable operation of the power grid. threaten.
The existing circuit breaker failure (dead zone) protection cannot meet the limit cut-off time required for power grid stability. Failure of the station domain specified in this document (Dead zone) protection is an application of the station domain protection system. It adopts a systematic protection concept to collect multi-interval analog and switch signals of the whole station.
Information, the use of fiber channel for rapid information exchange between stations to achieve comprehensive discrimination, can isolate the fault in the shortest time under the existing technical Most likely to meet the system stability requirements.
This document specifies the functional configuration requirements and technical principles of the station failure (dead zone) protection technology, and proposes the station failure (dead zone) protection.
The general structure of protection is helpful to the promotion and application of site failure (dead zone) protection across the country, and has guidance for the development of subsequent site protection. Guide meaning.
1 Scope
This document stipulates the overall requirements, functions and configuration, technical requirements, auxiliary equipment and two Requirements and tests of the secondary circuit.
This document is applicable to the protection of station failure (dead zone) in power plants and substations with dual circuit breaker wiring such as 3/2 circuit breakers. Other types Refer to the use of the protection of the wiring form.
2 Normative references
The content of the following documents constitutes an indispensable clause of this document through normative references in the text. Among them, dated quotations Only the version corresponding to the date is applicable to this document; for undated reference documents, the latest version (including all amendments) is applicable to this document.
GB/T 2900.1 Basic terminology for electrical engineering
GB/T 2900.17 Electrotechnical terminology measuring relay
GB/T 2900.49 Electrician Terminology Power System Protection
GB/T 7261 Basic test methods for relay protection and safety automatic devices
GB/T 14285 Technical Regulations for Relay Protection and Safety Automatic Equipment
GB/T 14598.24 Measuring relays and protection devices Part 24: Power system transient data exchange (COMTRADE) communication Use format
GB/T 20840.8 Transformer Part 8: Electronic Current Transformer
GB/T 21711.1 Basic Electromechanical Relay Part 1: General Principles and Safety Requirements
GB/T 25931 Accurate clock synchronization protocol for network measurement and control system
GB/T 26399 Technical Guidelines for Power System Security and Stability Control
GB/T 26864 Power System Relay Protection Product Dynamic Model Test
GB/T 34122 220kV~750kV Power Grid Relay Protection and Safety Automatic Device Configuration Technical Specification
DL/T 282 Technical Conditions of Merging Unit
DL/T 364 Fibre Channel Transmission Protection Information General Technical Conditions
DL/T 478 General technical requirements for relay protection and safety automatic devices
DL/T 860 (all parts) Electric power automation communication network and system
DL/T 1241 Technical Specification for Power Industry Ethernet Switch
DL/T 1782 Information Specification for Substation Relay Protection
The physical/electrical characteristics of the ITU-T G.703 series of digital interfaces (Physical/electricalcharacteristicsofhierarchical digitalinterfaces)
3 Terms and definitions
The terms and definitions defined in GB/T 2900.1, GB/T 2900.17, GB/T 2900.49 and DL/T 478 and the following terms and definitions apply to this document.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 2900.1Electrotechnical terminology - Fundamental terms
- GB/T 2900.17Electrotechnical terminology - Measuring relays and protection equipment
- GB/T 2900.49Electrotechnical terminology -- Power system protection
- GB/T 7261Basic test methods for protection relays and security automatic equipment
- GB/T 14285Technical code for relaying protection and security automatic equipment
- GB/T 14598.24Measuring relays and protection equipment -- Part 24: Common format for transient data exchange (COMTRADE) for power systems
DL/T 478 · DL/T 860
Similar standards
How to Download GB/T 40532-2021
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
DL/T 1241-2024 — Technical Specifications for Power Industrial Ethernet Switches
DL/T 1782-2017 — Information specification of substation relay protection
DL/T 282-2018 — Technical requirement for merging unit
Secure payment via Stripe
Payments accepted
GB/T 40532-2021
$225.00