GB/T 17626.15-2011 is the English-translated version of 电磁兼容 试验和测量技术 闪烁仪 功能和设计规范.
GB/T 17626.15-2011 — This section provides flicker measurement instrument functions and design specifications, intended for all practical voltage fluctuation waveform display flashes the correct Perceptual level.
This section lists information about the formation of such an instrument, given based on the output results for this part of the scintillation counter to Flicker severity assessment methods.
Some of the content in this section is the work of the International Union Electric (UIE) "harassment" of the Working Group based on some of the content is based on the IEEE's work, Other content is based on the IEC 's own work.
The scintillation specification relates to measuring input 230V/50Hz and 120V/60Hz; and to Other voltage and frequency specifications are under consideration. Note.
This section is based on the instrument specification data input voltage/frequency is given in the case of 230V/50Hz and 120V/60Hz, and for domestic use 220V/50Hz power grid, can be specifically calculated on the basis of the same specification and design theory.
This section applies to design analog or digital flicker measuring equipment to provide basic information, it did not give a flicker severity allowable limits.
Found what you need?
Document preview — GB/T 17626.15-2011
National Standard of the People's Republic of China
- ICS
- 33.100
- Classification
- L 06
Issued by: Standardization Administration of China
Contents
- Preface
- 1 Scope
- 2 Normative references
- 3 Instrument Description
- 4 4 Specification
- 5 Performance Test
- 6 Type testing and calibration specifications
- Appendix A (normative) to improve the accuracy of the method to assess flicker
- A.1 linear interpolation
- A.2 nonlinear interpolation within
- A.3 pseudo-zero intercept
- A.4 nonlinear classification
- The number of Annex B (Informative Appendix) deltaV/V meaning and voltage variations
- References
Foreword
GB/T 17626 "electromagnetic compatibility test and measurement technology" is divided into the following sections.
GB/T 17626.1-2006 Electromagnetic compatibility - Testing and measurement techniques - Overview of immunity tests GB/T 17626.2-2006 Electromagnetic compatibility - Testing and measurement techniques - Electrostatic discharge immunity test GB/T 17626.3-2006 Electromagnetic compatibility - Testing and measurement techniques RFEMS test GB/T 17626.4-2008 Electromagnetic compatibility - Testing and measurement techniques - Electrical fast transient burst immunity test GB/T 17626.5-2008 Electromagnetic compatibility - Testing and measurement techniques - Surge (impact) immunity test GB/T 17626.6-2008 Electromagnetic compatibility - Testing and measurement techniques Immunity to conducted disturbances induced field GB/T 17626.7-2008 Electromagnetic compatibility - Testing and measurement techniques - power supply systems and equipment connected harmonics, interharmonics measurements and Measuring Instruments Guide GB/T 17626.8-2006 Electromagnetic compatibility - Testing and measurement techniques - Power frequency magnetic field immunity test GB/T 17626.9-2011 Electromagnetic compatibility - Testing and measurement techniques - Pulse magnetic field immunity test GB/T 17626.10-1998 electromagnetic compatibility test and measurement techniques - Damped oscillatory magnetic field immunity test GB/T 17626.11-2008 Electromagnetic compatibility Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity test GB/T 17626.12-1998 electromagnetic compatibility test and measurement techniques - Oscillatory waves immunity test GB/T 17626.13-2006 electromagnetic compatibility test and measurement technology AC power port harmonics and interharmonics including mains signaling Low frequency immunity tests GB/T 17626.14-2005 Electromagnetic compatibility Testing and measurement techniques - Voltage fluctuation immunity test GB/T 17626.16-2007 electromagnetic compatibility test and measurement technology 0Hz ~ 150kHz common mode conducted disturbances immunity test GB/T 17626.17-2005 electromagnetic compatibility test and measurement technology dc input power port immunity test ripple GB/T 17626.27-2006 Electromagnetic compatibility Testing and measurement techniques - Unbalance, immunity test GB/T 17626.28-2006 electromagnetic compatibility test and measurement techniques - Variation of power frequency, immunity test GB/T 17626.29-2006 electromagnetic compatibility test and measurement technology dc input power port voltage dips, short interruptions and Voltage variations immunity tests this is Part 15 GB/T 17626 of.
This section drafted in accordance with GB/T 1.1-2009 given rules.
This section identical with the international standard IEC 61000-4-15:1997 A1.2003 (Version 1.1) "electromagnetic compatibility test and measurement technology Flashing surgery instrument functions and design specifications "and the following editorial changes.
--- Normative reference to IEC 61000-4 and IEC 61010-1 series of standards referenced in the file, its version is too low, taking into account these standard version change frequently, so it is changed to the corresponding national standards are not dated references;
--- Of Tables 4 to No. 8 have been adjusted. This section of Table 4 correspond to IEC 61000-4-15. in 2003.1997 A1
Table 8, 2003 Revision member new form; the full text of the standard in order to ensure the continuity of the table number, table numbers to change
Table 4, all subsequent table numbers sequentially adjusted.
Electromagnetic Compatibility This part of the National Standardization Technical Committee (SAC/TC246) and focal points.
This section is responsible for drafting unit. Shanghai Electric Apparatus Research Institute, Shanghai Sanki Co.
1 Scope
This section provides flicker measurement instrument functions and design specifications, intended for all practical voltage fluctuation waveform display flashes the correct Perceptual level. This section lists information about the formation of such an instrument, given based on the output results for this part of the scintillation counter to Flicker severity assessment methods.
Some of the content in this section is the work of the International Union Electric (UIE) "harassment" of the Working Group based on some of the content is based on the IEEE's work, Other content is based on the IEC 's own work. The scintillation specification relates to measuring input 230V/50Hz and 120V/60Hz; and to Other voltage and frequency specifications are under consideration.
Note. This section is based on the instrument specification data input voltage/frequency is given in the case of 230V/50Hz and 120V/60Hz, and for domestic use 220V/50Hz power grid, can be specifically calculated on the basis of the same specification and design theory.
This section applies to design analog or digital flicker measuring equipment to provide basic information, it did not give a flicker severity allowable limits.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 2423.1-2008 Environmental testing for electric and electronic products Part 2. Test methods Test A. Cold (IEC 60068-2-1:2007, IDT) GB/T 2423.2-2008 Environmental testing for electric and electronic products Part 2. Test methods Test B. Dry heat (IEC 60068-2-2:2007, IDT) GB/T 2423.22-2002 Environmental testing for electric and electronic products Part 2. Test methods - Test N. Temperature change (IEC 60068-2-14. 1984, IDT) GB 4793.1 measurement, control and laboratory safety requirements for electrical equipment - Part 1. General requirements (GB 4793.1-2007, IEC 61010-1:2001, IDT) GB/T 17626.2 Electromagnetic compatibility Testing and measurement techniques - Electrostatic discharge immunity test (GB/T 17626.2-2006, IEC 61000-4-2:2001, IDT) GB/T 17626.3 electromagnetic compatibility test and measurement technology RFEMS test (GB/T 17626.3-2006, IEC 61000-4-3:2002, IDT) GB/T 17626.4 Electromagnetic compatibility Testing and measurement techniques - Electrical fast transient burst immunity test (GB/T 17626.4-2008, IEC 61000-4-4:2004, IDT) GB/T 17626.5 electromagnetic compatibility test and measurement technology surge (impact) immunity test (GB/T 17626.5-2008, IEC 61000-4-5:2005, IDT) GB/T 17626.6 electromagnetic compatibility test and measurement technology RF field induced immunity to conducted disturbances (GB/T 17626.6-2008, IEC 61000-4-6:2006, IDT) GB/T 17626.8 Electromagnetic compatibility Testing and measurement techniques - Power frequency magnetic field immunity test (GB/T 17626.8-2006, IEC 61000-4-8:2001, IDT) GB/T 17626.9 Electromagnetic compatibility Testing and measurement techniques - Pulse magnetic field immunity test (GB/T 17626.9-2011, IEC 61000-4-9:2001, IDT) GB/T 17626.11 Electromagnetic compatibility Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 18 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 2423.1-2008Environmental testing for electric and electronic products - Part 2: Test methods - Tests A: Cold
- GB/T 2423.2-2008Environmental testing for electric and electronic products - Part 2: Test methods - Tests B: Dry heat
- GB/T 2423.22-2002Environmental testing - Part 2: Test methods - Test N: Change of temperature
- GB/T 17626.2Electromagnetic compatibility -- Testing and measurement techniques -- Electrostatic discharge immunity test
- GB/T 17626.2-2006Electromagnetic compatibility -- Testing and measurement techniques -- Electrostatic discharge immunity test
- GB/T 17626.3Electromagnetic compatibility - Testing and measurement techniques - Part 3: Radiated, radio-frequency, electromagnetic field immunity test
IEC 60068 · GB 4793.1 · GB 4793.1-2007 · IEC 61010 · IEC 61000
Cited by
- GB/T 20840.103-2020Instrument transformers - Part 103: The use of instrument transformers for power quality measurement
- GB/T 31365-2015Testing code for photovoltaic power station connected to power grid
- NB/T 32006-2013Test Code for Power Quality of Photovoltaic Power Station
- NB/T 32008-2013Testing Code for Power Quality of Inverters Used in Photovoltaic Power Station
- NB/T 20071-2012Requirements for Electrical Supplies of Instrumentation and Control Systems Important to Safety in Nuclear Power Plants
How to Download GB/T 17626.15-2011
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 17626.11-2023 — Electromagnetic compatibility - Testing and measurement techniques - Part 11: Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase
GB/T 17626.2-2018 — Electromagnetic compatibility -- Testing and measurement techniques -- Electrostatic discharge immunity test
GB/T 17626.20-2014 — Electromagnetic compatibility -- Testing and measurement techniques -- Emission and immunity testing in transverse electromagnetic (TEM) waveguide
Secure payment via Stripe
Payments accepted
GB/T 17626.15-2011
$290.00