GB/T 17626.11-2023Electromagnetic compatibility - Testing and measurement techniques - Part 11: Voltage dips, short interruptions and voltage variations immunity tests for equipment with input current up to 16 A per phase (English PDF)
电磁兼容 试验和测量技术 第11部分:对每相输入电流小于或等于16 A设备的电压暂降、短时中断和电压变化抗扰度试验
Open the GB/T 17626.11-2023 preview as PDF
This is a limited preview
Buy now to download the full PDF (44 pages)
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
May 23, 2023
Implementation date
June 1, 2024
Scope
GB/T 17626.11-2023 is the English-translated version of 电磁兼容 试验和测量技术 第11部分:对每相输入电流小于或等于16 A设备的电压暂降、短时中断和电压变化抗扰度试验.
GB/T 17626.11-2023 is Part 11 of the Chinese EMC testing series, and covers immunity to voltage dips, short interruptions and voltage variations for equipment drawing up to 16 A per phase. Dips are the commonest disturbance on any supply - a fault clears somewhere on the network and the voltage collapses for a few cycles - and equipment that resets, loses its configuration or trips when it happens is a recurring nuisance rather than a rare failure. Testing them well is harder than it looks, because the generator must produce the transition with a defined fall time and still supply the inrush current the equipment draws on recovery. The standard sets the test levels for dips, short interruptions and voltage variations, the test instrumentation covering the generator and the power source, the test setup and the test procedures, with an annex on the rationale for the rapid fall times. It took effect on 1 June 2024.
Document preview — GB/T 17626.11-2023
National Standard of the People's Republic of China
- ICS
- 33.100.20
- Classification
- L06
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- 3 Introduction...7
- 1 Scope...12
- 2 Normative references...12
- 3 Terms and definitions...13
- 4 General...15
- 5 Test levels...15
- 5.1 General...15
- 5.2 Voltage dips and short interruptions...16
- 5.3 Voltage variations...17
- 6 Test instrumentation...20
- 6.1 Test generator...20
- 6.2 Power source...23
- 7 Test set-up...23
- 8 Test procedures...24
- 8.1 General...24
- 8.2 Laboratory reference conditions...24
- 8.3 Execution of the test...25
- 9 Evaluation of test results...26
- 39 Bibliography...40
1 Scope
GB/T 17626.11-2023 is Part 11 of the Chinese EMC testing series, and covers immunity to voltage dips, short interruptions and voltage variations for equipment drawing up to 16 A per phase. Dips are the commonest disturbance on any supply - a fault clears somewhere on the network and the voltage collapses for a few cycles - and equipment that resets, loses its configuration or trips when it happens is a recurring nuisance rather than a rare failure. Testing them well is harder than it looks, because the generator must produce the transition with a defined fall time and still supply the inrush current the equipment draws on recovery. The standard sets the test levels for dips, short interruptions and voltage variations, the test instrumentation covering the generator and the power source, the test setup and the test procedures, with an annex on the rationale for the rapid fall times. It took effect on 1 June 2024.
This document defines the immunity test methods and range of preferred test levels for electrical and electronic equipment connected to low-voltage power supply networks for voltage dips, short interruptions, and voltage variations. This document applies to electrical and electronic equipment having a rated input current not exceeding 16 A per phase, for connection to
50 Hz AC networks. It does not apply to electrical and electronic equipment for connection to 400 Hz AC networks. Tests for these networks will be covered by future IEC documents. The object of this document is to establish a common reference for evaluating the immunity of electrical and electronic equipment when subjected to voltage dips, short interruptions and voltage variations. Note
1.Voltage fluctuation immunity tests are covered by IEC 61000-4-14. The test method documented in this document of GB/T 17626 describes a consistent method to assess the immunity of equipment or a system against a defined phenomenon. Note
2.As described in IEC Guide 107, this is a basic EMC publication for use by product committees of the IEC. As also stated in Guide 107, the IEC product committees are responsible for determining whether this immunity test standard should be applied or not, and, if applied, they are responsible for defining the appropriate test levels. Technical committee 77 and its sub- committees are prepared to co-operate with product committees in the evaluation of the value of particular immunity tests for their products.
2 Normative references
The following documents are referred to in the text in such a way that some or all of their content constitutes requirements of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
3 Terms and definitions
For the purposes of this document, the following terms and definitions apply.
3.1 immunity (to a disturbance) ability of a device, equipment or system to perform without degradation in the presence of an electromagnetic disturbance
3.2 voltage dip sudden reduction of the voltage at a particular point of an electricity supply system below a specified dip threshold followed by its recovery after a brief interval
3.3 short interruption sudden reduction of the voltage on all phases at a particular point of an electric supply system below a specified interruption threshold followed by its restoration after a brief interval
Note. Short interruptions are typically associated with switchgear operations related to the occurrence and termination of short circuits on the system or on installations connected to it.
3.4 residual voltage (of voltage dip) minimum value of RMS voltage recorded during a voltage dip or short interruption
3.5 malfunction breakdown of the ability of equipment to carry out intended functions or the execution of unintended functions by the equipment
3.6 calibration method to prove that the measurement equipment is in compliance with its specifications
3.7 verification set of operations which are used to check the test equipment system (e.g., the test generator and the interconnecting cables) to demonstrate that the test system is functioning within the specifications given in Clause 6
4 General
Electrical and electronic equipment can be affected by voltage dips, short interruptions or voltage variations of the power supply. Voltage dips and short interruptions occur due to faults in a (public or non-public) network or in installations by sudden changes of large loads. In certain cases, two or more consecutive dips or interruptions can occur. Voltage variations are caused by continuously varying loads connected to the network.
5 Test levels
5.1 General The voltages in this document use the rated voltage for the equipment (UT) as a basis for the voltage test level specification. Where the equipment has a rated voltage range the following shall apply.
5.2 Voltage dips and short interruptions The change between UT and the changed voltage is abrupt. The step can start and stop at any phase angle on the mains voltage. The following test voltage levels (in %UT) are used. 0%, 40%, 70% and 80%, corresponding to dips with residual voltages of 0%, 40%, 70% and 80%. The rise and fall time are detailed in Figure 3. The preferred test levels and durations given in Table 1 and Table 2 take into account the information given in IEC TR 61000-2-8. The preferred test levels in Table 1 are reasonably severe, and are representative of many real world dips, but are not intended to guarantee immunity to all voltage dips. More severe dips, for example 0% for 1 s and balanced three-phase dips, may be considered by product committees. The generator specification for voltage rise time, tr, and voltage fall time, tf, during abrupt changes is indicated in Table 4.
5.3 Voltage variations This test considers a defined transition between the rated voltage UT and the changed voltage.
6.1 Test generator
6.1.1 General The following features are common to the generator for voltage dips, short interruptions and voltage variations, except as indicated. Examples of generators are given in Annex C.
6.1.2 Performance and characteristics of the generator UT (RMS) See Table 4 for technical specifications for the performance and characteristics of the generator.
6.1.3 Verification of the characteristics of the voltage dips, short interruptions generators For output voltages of 70% and 40% of the nominal value, the above requirements need only be verified for a maximum of 3 s duration. For output voltages of 40% of the nominal value it is acceptable to verify the load regulation requirements either at 200 V ~ 240 V nominal voltage or at 100 V ~ 120 V nominal voltage.. The 100 Omega resistive load used to test the generator should not have additional inductivity. Rise and fall time, as well as overshoot and undershoot, shall be verified for switching at both 90° and 270°, from 0% to 100%, 100% to 80%, 100% to 70%, 100% to 40%, and 100% to 0%. Phase angle accuracy shall be verified for switching from 0% to 100% and 100% to 0%, at nine phase angles from 0° to 360° in 45° increments. It shall also be verified for switching from 100% to 80% and 80% to 100%, 100% to 70% and 70% to 100%, as well as from 100% to 40% and 40% to 100%, at 90° and 180°. The voltage generators shall, preferably, be recalibrated at defined time periods in accordance with a recognized quality assurance system.
6.2 Power source The frequency of the test voltage shall be within ±2% of rated frequency.
7 Test set-up
The test shall be performed with the EUT connected to the test generator with the shortest power supply cable as specified by the EUT manufacturer. If no cable length is specified, it shall be the shortest possible length suitable to the application of the EUT. The test set-ups are defined for the three types of phenomena described in this document. Figure C.1a) shows a schematic for the generation of voltage dips, short interruptions and voltage variations with gradual transition between rated and changed voltage using a generator with internal switching. In Figure C.1b) a generator and a power amplifier are used.
8 Test procedures
8.1 General Before starting the test of a given EUT, a test plan shall be prepared. The test plan should be representative of the way the system is actually used. Systems can require a precise pre-analysis to define which system configurations shall be tested to reproduce field situations. Test cases shall be explained and indicated in the test report. It is recommended that the test plan include the following items. If the actual operating signal sources are not available to the EUT, they can be simulated. For each test, any degradation of performance shall be recorded. The monitoring equipment should be capable of displaying the status of the operational mode of the EUT during and after the tests. After each group of tests, a full functional check shall be performed.
8.2 Laboratory reference conditions
8.2.1 Climatic conditions Unless otherwise specified by the committee responsible for the generic or product standard, the climatic conditions in the laboratory shall be within any limits specified for the operation of the EUT and the test equipment by their respective manufacturers. Tests shall not be performed if the relative humidity is so high as to cause condensation on the EUT or the test equipment.
8.2.2 Electromagnetic conditions The electromagnetic conditions of the laboratory shall be such as to guarantee the correct operation of the EUT in order not to influence the test results.
8.3 Execution of the test
8.3.1 General During the tests, the mains voltage for testing shall be monitored within an accuracy of ±2%.
8.3.2 Voltage dips and short interruptions The EUT shall be tested for each selected combination of test level and duration with a sequence of three dips/interruptions with intervals of 10 s minimum (between each test event). Each representative mode of operation shall be tested. For short interruptions, the angle shall be defined by the product committee as the worst case. In the absence of definition, it is recommended to use 0° for one of the phases. For the short interruption test of three-phase systems, all the three phases shall be simultaneously tested according to 5.2. For the voltage dips test of single-phase systems, the voltage shall be tested according to 5.2.This implies one series of tests. For the voltage dips test of three-phase systems with neutral, each individual voltage (phase-to-neutral and phase-to-phase) shall be tested, one at a time, according to 5.2. This implies six different series of tests. See Figure 5. For the voltage dips test of three-phase systems without neutral, each phase-to-phase voltage shall be tested, one at a time, according to 5.2.This implies three different series of tests. See Figure 5b).
8.3.3 Voltage variations The EUT is tested to each of the specified voltage variations, three times at 10 s interval for the most representative modes of operations.
9 Evaluation of test results
The test results shall be classified in terms of the loss of function or degradation of performance of the equipment under test, relative to a performance level defined by its manufacturer or the requestor of the test, or agreed between the manufacturer and the purchaser of the product. The recommended classification is as follows:
a) normal performance within limits specified by the manufacturer, requestor or purchaser;
b) temporary loss of function or degradation of performance which ceases after the disturbance ceases, and from which the equipment under test recovers its normal performance, without operator intervention;
c) temporary loss of function or degradation of performance, the correction of which requires operator intervention;
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 44 pages — is available in the English PDF.
Referenced standards
Cited by
- GB/T 32580.5-2026Railway applications - Fixed installations - AC high voltage switchgear and instrument transformers - Part 5: 27.5 kV and 2×27.5 kV metal-enclosed switchgear and controlgear
- GB/T 26862-2025Test specifications of synchrophasor measurement device for power systems
- GB/T 45310-2025Specification for main control system of solar power tower plant
- GB/T 45466-2025Gas-fired clothes dryer
- GB/T 45524-2025Public security — Flammable and explosive gas detection and alarm device
- GB/T 45991-2025Evaluation specification for communication quality of household and similar electrical appliances
Similar standards
GB 38031-2025|GB/T 17626.11|GB/T 17626.11-2008|GB/T 17626.11-1999|GB/T 17626|GB/T 17626.2|GB/T 17626.1|GB/T 17626.9
How to Buy GB/T 17626.11-2023
- 1Add to cart. Click the "Buy GB/T 17626.11-2023" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 17626.12-2023 — Electromagnetic compatibility - Testing and measurement techniques - Part 12: Ring wave immunity test