Scope

GB/T 17626.6-2017 (Electromagnetic compatibility -- Testing and measurement techniques -- Immunity to conducted disturbances, induced by radio-frequency fields) is available as an English-translated PDF.

GB/T 17626.6-2017 — This Part of GB/T 17626 relates to the conducted immunity requirements of electrical and electronic equipment to electromagnetic disturbances coming from intended radio-frequency (RF) transmitters in the frequency range 150kHz up to 80MHz.

Found what you need?

Document preview — GB/T 17626.6-2017

National Standard of the People's Republic of China

ICS
33.100.20
Classification
L 06

Issued by: General Administration of Quality Supervision, Inspection and Quarantine

Contents

  • Foreword...4
  • 1 Scope...8
  • 2 Normative References...8
  • 3 Terms and Definitions...9
  • 4 General...10
  • 5 Test Levels...13
  • 6 Test Equipment and Level Adjustment Procedures...14
  • 6.1 Test generator...14
  • 6.2 Coupling and decoupling devices...15

Foreword

Currently, GB/T 17626 Electromagnetic Compatibility – Testing and Measurement Techniques

includes the following parts.

--- GB/T 17626.1-2006 Electromagnetic Compatibility - Testing and Measurement

Techniques - Overview of Immunity Tests;

--- GB/T 17626.2-2006 Electromagnetic Compatibility(EMC) - Testing and Measurement

Techniques - Electrostatic Discharge Immunity Test;

--- GB/T 17626.3-2016 Electromagnetic Compatibility- Testing and Measurement

Techniques- Radiated, Radio-Frequency, Electromagnetic Field Immunity Test;

--- GB/T 17626.4-2008 Electromagnetic Compatibility - Testing and Measurement

Techniques - Electrical Fast Transient/Burst Immunity Test;

--- GB/T 17626.5-2008 Electromagnetic Compatibility - Testing and Measurement

Techniques - Surge Immunity Test;

--- GB/T 17626.6-2017 Electromagnetic Compatibility - Testing and Measurement

Techniques - Immunity to Conducted Disturbances, Induced by Radio-Frequency Fields;

--- GB/T 17626.7-2008 Electromagnetic Compatibility - Testing and Measurement

Techniques - General Guide on Harmonics and Inter-Harmonics Measurements and

Instrumentation for Power Supply Systems and Equipment;

--- GB/T 17626.8-2006 Electromagnetic Compatibility (EMC) - Part 8.Testing and

Measurement Techniques - Power Frequency Magnetic Field Immunity Test;

--- GB/T 17626.9-2011 Electromagnetic Compatibility - Testing and Measurement

Techniques - Pulse Magnetic Field Immunity Test;

--- GB/T 17626.10-1998 Electromagnetic Compatibility - Testing and Measurement

Techniques - Damped Oscillatory Magnetic Field Immunity Test;

--- GB/T 17626.11-2008 Electromagnetic Compatibility - Testing and Measurement

Techniques - Voltage Dips, Short Interruptions and Voltage Variations Immunity Tests;

--- GB/T 17626.12-2013 Electromagnetic Compatibility - Testing and Measurement

Techniques - Ring Wave Immunity Test;

--- GB/T 17626.13-2006 Electromagnetic Compatibility (EMC) - Testing and Measurement

Techniques - Harmonics and Inter-harmonics including Mains Signalling at A.C. Power

Port Low Frequency Immunity Test;

--- GB/T 17626.14-2005 Electromagnetic Compatibility - Testing and Measurement

Techniques - Voltage Fluctuation Immunity Test;

--- GB/T 17626.15-2011 Electromagnetic Compatibility—Testing and Measurement

Techniques – Flickermeter - Functional and Design Specifications;

--- GB/T 17626.16-2007 Electromagnetic Compatibility - Testing and Measurement

Techniques - Test for Immunity to Conducted Common Mode Disturbances in the

Frequency Range 0 Hz to 150 kHz;

--- GB/T 17626.17-2005 Electromagnetic Compatibility - Testing and Measurement

Techniques - Ripple on D.C. Input Power Port Immunity Test;

--- GB/T 17626.18-2016 Electromagnetic Compatibility - Testing and Measurement

Techniques - Damped Oscillatory Wave Immunity Test;

--- GB/T 17626.20-2014 Electromagnetic Compatibility - Testing and Measurement

Techniques - Emission and Immunity Testing in Transverse Electromagnetic (TEM)

Waveguide;

--- GB/T 17626.21-2014 Electromagnetic Compatibility - Testing and Measurement

Techniques - Reverberation Chamber Test Methods

--- GB/T 17626.24-2012 Electromagnetic Compatibility - Testing and Measurement

Techniques - Test Methods for Protective Devices for HEMP Conducted Disturbance;

--- GB/T 17626.27-2006 Electromagnetic Compatibility (EMC) - Testing and Measurement

Techniques - Unbalance Immunity Test;

--- GB/T 17626.28-2006 Electromagnetic Compatibility (EMC) - Testing and Measurement

Techniques - Variation of Power Frequency Immunity Test;

--- GB/T 17626.29-2006 Electromagnetic Compatibility (EMC) - Testing and Measurement

Techniques - Voltage Dips Short Interruptions and Voltage Variations on D.C. Input

Power Port Immunity Tests;

--- GB/T 17626.30-2012 Electromagnetic Compatibility - Testing and Measurement

Techniques - Power Quality Measurement Methods;

--- GB/T 17626.34-2012 Electromagnetic Compatibility—Testing and Measurement

Techniques - Voltage Dips, Short Interruptions and Voltage Variations Immunity Tests

for Equipment with Mains Current More than 16 Aper Phase.

This Part is Part 6 of GB/T 17626.

This Part was drafted as per the rules specified in GB/T 1.1-2009.

This Part replaced GB/T 17626.6-2008 Electromagnetic Compatibility - Testing and

Measurement Techniques - Immunity to Conducted Disturbances Induced by Radio-Frequency

Fields. Compared with GB/T 17626.6-2008, the major technical contents of this Part are as

follows.

--- Modify the use of some CDNs;

--- Modify the calibration method of the current clamp;

--- Re-edited Clause 7 "Test Arrangement and Injection Method";

--- Modify Annex A, adding decoupling clamps, etc.;

--- Add Annex G Measurement Uncertainty of the Voltage Test Level;

--- Add informative Annexes H, I and J.

This Part used the translation method to equivalently adopt IEC 61000-4-6.2013 (Edition 4.0)

Electromagnetic Compatibility (EMC) – Part 4-6.Testing and Measurement Techniques –

Immunity to Conducted Disturbances, Induced by Radio-Frequency Fields.

The Chinese documents that have consistent correspondence with the international documents

normatively cited in this Part are as follows.

--- GB/T 4365-2003 Electrotechnical Terminology - Electromagnetic Compatibility [IEC

60050(161).1990, IDT]

In order to comply with the compilation requirements of national standards and Chinese

expression habits and to correct several clerical errors in IEC61000-4-6.2013, the following

editorial changes have been made in this Part.

--- Change the original standard name "Electromagnetic Compatibility (EMC) – Part 4-6.

Testing and Measurement Techniques – Immunity to Conducted Disturbances, Induced

by Radio-Frequency Fields" into "Electromagnetic Compatibility –Testing and

Measurement Techniques – Immunity to Conducted Disturbances, Induced by Radio-

Frequency Fields";

--- Modify the Paragraph 1 of Clause 5 from "intentional electromagnetic fields emitted

from RF transmitters" into "electromagnetic fields emitted from RF transmitters";

--- Change the location of NOTE 1 in 6.2 behind Table 3;

--- CORRECT "when the guidance of 7.4.1 is followed" in NOTE 1 of 6.2.3.1 INTO "when

the guidance of 7.7 is followed";

--- CORRECT "uncertainty related to 7.4.1 is not considered in Annex G" in NOTEs 15 and

21 of Annex G INTO "uncertainty related to 7.7 is not considered in Annex G";

--- Add an item in Bibliography.

This Part was proposed by and under the jurisdiction of National Technical Committee on

Electromagnetic Compatibility of Standardization Administration of China (SAC/TC 246).

Drafting organization of this Part. The 3rd Research Institute of China Electronics Technology

Group Corporation.

Chief drafting staffs of this Part. Xu Wei, Ding Shaohua, Lin Jingping, Zhang Xiaogang, and

Fu Zhaofeng.

The historical editions replaced by this Standard are as follows.

--- GB/T 17626.6-1998, GB/T 17626.6-2008.

Electromagnetic Compatibility – Testing and Measurement

Techniques – Immunity to Conducted Disturbances, Induced

by Radio-Frequency Fields

1 Scope

This Part of GB/T 17626 relates to the conducted immunity requirements of electrical and

electronic equipment to electromagnetic disturbances coming from intended radio-frequency

(RF) transmitters in the frequency range 150kHz up to 80MHz.

2 Normative References

The following documents are essential to the application of this document. For the dated

documents, only the versions with the dates indicated are applicable to this document; for the

undated documents, only the latest version (including all the amendments) is applicable to this

document.

IEC 60050(161) International Electrotechnical Vocabulary (IEV) – Chapter 161.

Electromagnetic Compatibility

3 Terms and Definitions

For the purposes of this document, the terms and definitions given in IEC 60050(161) as well

as the following apply.

3.1 Artificial hand

Electrical network simulating the impedance of the human body under average operational

conditions between a hand-held electrical appliance and earth.

3.2 Auxiliary equipment; AE

Equipment necessary to provide the equipment under test (EUT) with the signals required for

normal operation and equipment to verify the performance of the EUT.

4 General

The source of disturbance covered by this Part is basically an electromagnetic field, coming

from intended RF transmitters, that may act on the whole length of cables connected to installed

equipment.

5 Test Levels

According to this standard, tests are required for induced disturbances caused by

electromagnetic fields coming from RF transmitters in the frequency range 150kHz to 80MHz.

6 Test Equipment and Level Adjustment Procedures

6.1 Test generator

The test generator includes all equipment and components for supplying the input port of each

coupling device with the disturbing signal at the required signal level at the appropriate

injection point.

7 Test Setup and Injection Methods

7.1 Test setup

The equipment to be tested is placed on an insulating support of 0.1 m ± 0.05 m height above

a reference ground plane.

7.2 EUT comprising a single unit

The EUT shall be placed on an insulating support 0.1 m above the reference ground plane.

8 Test Procedure

The EUT shall be tested within its intended operating and climatic conditions.

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Normative references

IEC 60050

Cited by

How to Download GB/T 17626.6-2017

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 17626.6-2017

$930.00