Scope

GB/T 16597-2019 is the English-translated version of 冶金产品分析方法 X射线荧光光谱法通则.

GB/T 16597-2019 is the general rule that Chinese metallurgical laboratories follow when they analyse materials by X-ray fluorescence spectrometry.

It covers the terms used, the basic principles of wavelength dispersive and energy dispersive instruments, the instruments themselves and their parameters, the reagents and materials, the ways of preparing the sample, and qualitative, semi-quantitative and quantitative analysis, together with the common software, the safety precautions and the recording of results.

Samples may be prepared as polished solids, powder briquettes, fused glass beads, solutions or thin films. It applies to the measurement of all elements from 4Be to 92U except H, He and Li, over a mass fraction range of 0.0001 % to 100 %, and cites GB/T 6379.2 and JJG 810.

It replaces GB/T 16597-1996, was issued on 4 June 2019 and has applied since 1 May 2020.

Found what you need?

Document preview — GB/T 16597-2019

National Standard of the People's Republic of China

ICS
77.040.30
Classification
H 10
Replacing
GB/T 16597-1996

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword3
  • 1 Scope5
  • 2 Normative references5
  • 3 Terms and definitions5
  • 4 Fundamentals10
  • 5 Instruments11
  • 6 Reagents and materials20
  • 7 Preparation method of sample20
  • 8 Qualitative analysis21
  • 9 Semi-quantitative analysis22
  • 10 Quantitative analysis22
  • 11 Common analysis software26
  • 12 Safety precautions26
  • 13 Recording and presentation of measurement results26

1 Scope

This standard specifies the general requirements for quantitative analysis of elements by X-ray fluorescence spectrometry, including terms and definitions, basic principles, instruments, reagents and materials, preparation methods of samples, quantitative analysis, safety precautions, records and expression of measurement results.

This standard applies to wavelength dispersive and energy dispersive X-ray fluorescence spectrometers, to measure the element composition and element content in various materials. It can be used for qualitative and quantitative analysis of constant and trace of all elements from 4Be to 92U in the periodic table, in addition to H, He, Li, for wavelength dispersive and energy dispersive X-ray fluorescence spectrometers, which use X-ray tubes as excitation sources. The mass fraction range of the analyzed elements: 0.0001% ~ 100%.

2 Normative references

The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) is applicable to this standard.

GB/T 6379.2 Accuracy of measurement methods and results (trueness and precision) - Part 2: Basic methods for determining the repeatability and reproducibility of standard measurement methods

JJG 810 Wavelength dispersive X-Ray fluorescence spectrometers

3 Terms and definitions

The following terms and definitions apply to this document.

3.1 X-ray intensity

The count of intensity in X-ray fluorescence spectroscopic analysis per unit time, usually represented by I.

3.2 Energy resolution

The ratio -- of the half height width of the pulse height distribution TO the average pulse height, expressed as a percentage.

3.3 Background

The continuum superimposed on the analytical line, which is mainly due to the scattering of incident radiation by the sample.

3.4 Analytical line

The characteristic spectral line, whose intensity needs to be measured to determine the content of the analyzed element accordingly.

Note: In X-ray fluorescence spectroscopic analysis, the characteristic spectral lines with high intensity, less interference, low background are generally selected as the analytical lines.

3.5 Interference line

Spectral line, that overlaps or partially overlaps with the analytical line, thereby affecting the accurate measurement of the analytical line intensity.

4 Fundamentals

4.1 Basic principles of wavelength dispersive X-ray fluorescence spectroscopy

The atoms of elements are excited by high-energy radiation, to cause the transition of electrons in the inner shell, at the same time emit X-rays with a certain characteristic wavelength.

4.2 Basic principles of energy dispersive X-ray fluorescence spectroscopy

The analysis sample is excited by the excitation source, to emit characteristic X-rays.

An X-ray detector, which has a certain energy resolution, is used to detect various energy characteristic X-rays, which are emitted by the sample.

5 Instruments

5.1 Composition of instrument

5.1.1 Wavelength dispersive X-ray fluorescence spectrometer

The schematic diagram of the wavelength dispersive X-ray fluorescence spectrometer is as shown in Figure 2.

5.1.2 Energy dispersive X-ray fluorescence spectrometer
5.1.2.1 Instrument composition

The composition of the energy dispersive X-ray fluorescence spectrometer is as shown in Figure 3; the whole set consists of four parts.

5.1.3 X-ray generator

The X-ray generator is composed of X-ray tube, high-voltage power supply, and controller.

5.1.5 X-ray analysis target
5.1.5.1 Commonly used targets for wavelength dispersive X-ray fluorescence analyzers
5.1.7 Counting-recording systems

Select the desired pulses from the output pulses of the detector to count; display and record it. It is composed of a pre-positioned amplifier, a single-channel wave height analyzer, a scaler, a timer, and a counting rate meter. The functions of each part are as follows: […]

5.1.8 Data processing system

The computer and its software are used to correct the X-ray intensity AND convert it into the content of the analyzed elements.

5.1.9 Ventilation mechanism

In order to reduce the absorption of long-wave X-rays by the atmosphere, there shall be a vacuum system or a helium replacement system, as well as a device to maintain its pressure stably.

5.2 Selection of instrument parameters

5.2.1 Optical path medium

It is divided into three different optical path media: air, vacuum, helium. Light elements shall be measured in vacuum media. Liquid and wet powder samples shall be measured in a helium system, because of the evaporation of water; however, only elements after fluorine can be measured.

5.2.3 Commonly used analyzing crystals and their scope of application

Commonly used analyzing crystals and their scope of application are listed in Table 3.

5.2.4 Recommended instrument parameters

The recommended instrument parameters for wavelength dispersive X-ray fluorescence analysis are as shown in Figure 6.

5.3 Placement of instrument

In order to keep the X-ray fluorescence spectrometer in normal working condition, the following points shall be paid attention to, when placing the instrument.

5.4 Calibration of instrument

In addition to doing daily maintenance and correcting the drift of the instrument with standardized samples, the technical indicators of the instrument shall be verified regularly every year, including precision, stability, X-ray counting rate, detector resolution, counting linearity of the instrument.

6 Reagents and materials

6.1 Lithium tetraborate (Li2B4O7). Before use, ignite at 600 °C for 4 hours; cool and seal for later use; it is superior grade or analytical grade.

6.2 Lithium metaborate (LiBO2): before use, ignite at 600 °C for 4 hours; cool and seal for later use; it is superior grade or analytical grade.

6.6 Lithium bromide (LiBr). Superior grade or analytical grade.

6.7 Ammonium iodide (NH4I). Superior grade or analytical grade.

6.8 Oxides or salts (depending on the analysis task). Spectrally pure or superior grade.

6.9 Inorganic acid. Analytically grade.

6.10 Plastic ring. Made of polyvinyl chloride material; used to strengthen the powder briquette sample during the sample preparation process of the powder briquette method.

6.11 Metal ring. Its function is the same as that of plastic ring.

7 Preparation method of sample

7.1 Solid sample preparation method

For bulk samples such as metal, alloy, cast iron, ore, glass, etc., if a suitable standard sample can be found, the bulk sample can be put into the instrument for measurement, as long as it is cut and surface polished.

7.2 Powder briquette method

Weigh an appropriate amount of powdery sample, which has a particle size of less than 75 µm.

7.3 Vitreous fusion method

In the gold platinum crucible, quantitatively weigh the analysis sample, the main flux, the flux aid, the oxidizing agent and the release agent, which has a suitable particle size, in a certain proportion. After mixing evenly, put the crucible into melting machine or muffle furnace, which was preheated to 1000 °C ~ 1200 °C for melting. After melting, transfer to the preheated gold platinum mold, to cool and solidify.

7.4 Solution sample preparation method

Carry out chemical treatment of a solid sample, to convert it into a solution. The standard solution and the analytical sample solution shall be similar in terms of composition and pH.

7.5 Thin film sample preparation method

For powder samples, which have a particle size of less than 48 µm, it can be sprayed on the tape; OR sprayed on the supporting material such as filter paper by spraying technology; OR the powder sample can be mixed with an organic reagent to form a jelly, then coated on the supporting material; OR the powder sample is made into a solution, […]

8 Qualitative analysis

According to the analysis requirements, first determine the measurement conditions (X- ray tube current and voltage, analyzing crystal, angle scanning range, etc.). Then scan the specimen. Record the scanning process with a recorder. Then obtain a spectral line intensity and angle 2theta scanning picture.

9 Semi-quantitative analysis

Select or synthesize a standard sample, which is basically similar to the analytical sample in terms of chemical composition and physical properties after sample preparation. […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 26 pages — is available in the English PDF.

Referenced standards

Cited by

Similar standards

Editions of GB/T 16597

EditionTitleRevisionStatus
GB/T 16597-2019Analytical methods of metallurgical products—General rule for X-ray fluorescence spectrometric methodscurrent editionCurrent
GB/T 16597-1996Analytical methods of metallurgical products—General rule for X-ray fluorescence spectrometric methodsprevious editionSuperseded

This page sells the current edition, GB/T 16597-2019. Earlier editions are listed for reference only.

How to Download GB/T 16597-2019

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
26 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 16597-2019

$235.00