Scope

SN/T 1849-2006 (Rules for the quarantine of import soybean) is available as an English-translated PDF.

SN/T 1849-2006 is the Chinese standard "Rules for the quarantine of import soybean". Its scope clause reads: This Standard specifies the X-ray fluorescence spectrometric method for determination of sulfur, phosphorus, arsenic and chloride in coal.

This Standard is applicable to the determination of sulfur, phosphorus, arsenic and chlorine content in imported and exported bitumite, anthracite and lignite. The measurement range of each element is shown in Table 1.

Table 1 – Measurement Range of Each Element. Its clauses include method summary; reagents and materials; apparatus; sampling and sample preparation; preparation of specimen; analytical procedures.

It was issued by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China on 2010-11-01 and took effect on 2011-05-01.

Found what you need?

Document preview — SN/T 1849-2006

National Standard of the People's Republic of China

Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China

Contents

  • Foreword...3
  • 1 Scope...4
  • 2 Normative References...4
  • 3 Method Summary...5
  • 4 Reagents and Materials...5
  • 5 Apparatus...5
  • 6 Sampling and Sample Preparation...5
  • 7 Preparation of Specimen...6
  • 8 Analytical Procedures...6
  • 9 Measurement...7
  • 10 Calculation of Results...7
  • 11 Precision...7
  • Appendix A (Informative) Preparation of Standard Sample...8

1 Scope

This Standard specifies the X-ray fluorescence spectrometric method for determination of sulfur, phosphorus, arsenic and chloride in coal.

This Standard is applicable to the determination of sulfur, phosphorus, arsenic and chlorine content in imported and exported bitumite, anthracite and lignite. The measurement range of each element is shown in Table 1.

Table 1 – Measurement Range of Each Element

2 Normative References

The following documents are essential to the application of this Document. For the dated documents, only the versions with the dates indicated are applicable to this Document; for the undated documents, only the latest version (including all the amendments) is applicable to this

Document.

GB/T 212 Proximate analysis of coal

GB/T 474 Preparation method of coal sample

GB/T 475 Method for manual sampling of commercial coal

GB/T 483 General rules for analytical and testing methods of coal

GB/T 6682 Water for analytical laboratory use - Specification and test methods

Element Measurement range (mass fraction)

GB/T 16597 Analytical methods of metallurgical products - General rule for X-ray fluorescence spectrometric methods

3 Method Summary

Grind the coal sample to a certain fineness and press it into sheets; and measure the X-ray fluorescence intensity of the element to be measured. Based on the quantitative relationship between the X-ray fluorescence intensity of the element to be measured and the content of the element to be measured, the regression equation and mathematical correction mode are selected to calculate the content of the element to be measured.

4 Reagents and Materials

Unless otherwise specifies, all the used reagents are analytically pure, while water is Class-II water specified in GB/T 6682.

4.1 Silicon dioxide, reference reagent; burn for 1h at 1000°C; and store in the dryer.

4.2 Sodium chloride, reference reagent; bake to constant weight at 500°C; and store in the dryer.

4.3 Boric acid, bake for 1h at 105°C; and store in the dryer.

4.4 Microcrystalline cellulose.

4.5 Gas, the gas ratio used by the flow counter is a mixture of 90% argon and 10% methane.

5 Apparatus

5.1 Wavelength dispersive X-ray fluorescence spectrometer, in compliance with the provisions

of GB/T 16597.

5.2 Analytical balance, sensitivity is 0.2mg.

5.3 Tablet press, the pressure is no less than 200kN.

5.4 Grinding facilities, agate, corundum or tungsten carbide mortar and pestle; automatic

grinding equipment can also be used.

6 Sampling and Sample Preparation

Sampling and sample preparation shall be carried out in accordance with the provisions of GB/T

475 and GB/T 474. The particle size shall be less than 0.2mm.

7 Preparation of Specimen

Place the air-dried coal sample (Clause 6) in the mortar (5.4) of the grinding facility and grind it to a particle size less than 75µm.

8 Analytical Procedures

8.1 Determination of moisture content in the specimen

Test the moisture content of the specimen (Clause 7) according to the provisions of GB/T 212.

Weigh a certain amount of air-dried coal sample (Clause 6), place it in a 105°C oven; and dry it in the air flow to constant weight. The moisture content shall be calculated according to the mass loss of the specimen.

8.2 Preparation of specimen sheet

Accurately weigh 7g of the ground specimen (Clause 7) and 1g of microcrystalline cellulose in the mortar (5.4) of the grinding facility, accurate to 0.2mg. After grinding until fully mixed, weigh about 6g, accurate to 0.1g; rim with boric acid (4.3) as the base; and press with a tablet press (5.3) under a pressure of 300kN for 40 s to form a specimen sheet. Use an ear cleaning ball to blow away any particulate matter that may be present on the surface and place it in a dryer. Avoid contact with the surface of the specimen to prevent contamination and damage to the specimen sheet.

After preparing the specimen sheet, visually inspect whether the specimen is smooth and flat.

If the test piece has defects such as cracks or falling off, it shall be discarded and a new qualified specimen sheet shall be prepared.

8.3 Preparation of standard sample sheet

The selected standard samples shall cover the content range of each element given in Table 1.

The serial standard samples are formed by using coal certified reference materials, coal certified reference materials compounded with coal certified reference materials and mixed with silicon dioxide (4.1), sodium chloride (4.2) and other methods, see Appendix A.

Prepare standard samples into standard sample sheets according to 8.2.

8.4 Drawing of standard curve

8.4.1 Measurement conditions

The measurement conditions for the characteristic spectral lines of each element were obtained through optimization, see Appendix B.

8.4.2 Preparation and calibration of standard curve

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 8 pages — is available in the English PDF.

Referenced standards

How to Download SN/T 1849-2006

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
8 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

SN/T 1849-2006

$225.00