Valid

GB/T 24180-2020Cold-reduced electrolytic chromium/chromium oxide coated steel sheet and strip (English PDF)

冷轧电镀铬钢板及钢带

Preview PDF

This is a limited preview

Buy now to download the full PDF (44 pages)

Need quotation for your management?

Get a formal quotation for GB/T 24180-2020 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

June 2, 2020

Implementation date

January 1, 2021

Scope

GB/T 24180-2020 is the English-translated version of 冷轧电镀铬钢板及钢带.

GB/T 24180-2020 is the Chinese standard for cold-reduced electrolytic chromium/chromium oxide coated steel sheet and strip.

It gives the terms and definitions, the classification and codes, designations and labels, the order content, the dimensions, shapes and weights, the technical requirements, the test methods, the inspection rules, and the packaging, marking and quality certificate.

It applies to cold-reduced electrolytic chromium/chromium oxide coated steel sheet and strip. Steel mills, can makers and packaging buyers use it. Issued on 2 June 2020, it has applied since 1 January 2021, replacing GB/T 24180-2009.

Found what you need?

Document preview — GB/T 24180-2020

National Standard of the People's Republic of China

ICS
77.140.50
Classification
H 46
Replacing
GB/T 24180-2009

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword3
  • 1 Scope5
  • 2 Normative References5
  • 3 Terms and Definitions7
  • 4 Classification and Codes, Designations and Labels7
  • 5 Order Content8
  • 6 Dimensions, Shapes and Weights8
  • 7 Technical Requirements16
  • 8 Test Methods21
  • 9 Inspection Rules23
  • 10 Packaging, Marking and Quality Certificate23
  • 11 A Comparison of Similar Quenching and Tempering Degree Codes between this Standard and Relevant International Standards24
  • Appendix A (normative) Rebound Test Method for Secondary Cold-reduced Sheet25
  • Appendix B (normative) Test Method for the Amount of Metal Chromium Coating on the Surface of Chromium Coated Sheet27
  • Appendix C (normative) Test Method for the Amount of Chromium Oxide Coating on the Surface of Chromium Coated Sheet35
  • Appendix D (normative) Conversion Table of HR15TSm and HR30TSm42
  • Appendix E (informative) A Comparison of Quenching and Tempering Degree Codes (or steel grade codes) between This Standard and Relevant International Standards43
  • Bibliography44

1 Scope

This Standard specifies the classification and codes, designations and labels, dimensions, shapes, weights, technical requirements, test methods, inspection rules, packaging, marking and quality certificate of cold-reduced electrolytic chromium / chromium oxide coated steel sheet and strip.

This Standard is applicable to primary cold-reduced electrolytic chromium / chromium oxide coated steel sheet and strip with a nominal thickness of 0.14 mm ~ 0.80 mm, as well as secondary cold-reduced electrolytic chromium / chromium oxide coated steel sheet and strip with a nominal thickness of 0.12 mm ~ 0.36 mm (hereinafter referred to as steel sheet and strip).

2 Normative References

The following documents are indispensable to the application of this document. In terms of references with a specified date, only versions with a specified date are applicable to this document. In terms of references without a specified date, the latest version (including all the modifications) is applicable to this document.

GB/T 222 Permissible Tolerances for Chemical Composition of Steel Products

GB/T 223.5 Steel and Iron - Determination of Acid-soluble Silicon and Total Silicon Content - Reduced Molybdosilicate Spectrophotometric Method

GB/T 223.9 Iron Steel and Alloy - Determination of Aluminum Content - Chrome Azurol S Photometric Method

GB/T 223.11 Iron, Steel and Alloy - Determination of Chromium Content - Visual Titration or Potentiometric Titration Method

GB/T 223.18 Methods for Chemical Analysis of Iron, Steel and Alloy - The Sodium Thiosulfate Separation Iodimetric Method for the Determination of Copper Content

GB/T 223.23 Iron, Steel and Alloy - Determination of Nickel Content - The Dimethylglyoxime Spectrophotometric Method

GB/T 223.26 Iron, Steel and Alloy - Determination of Molybdenum Content - The Thiocyanate Spectrophotometric Method

GB/T 223.29 Iron, Steel and Alloy - Determination of Lead Content - Carrier Precipitation-xylenol Orange Spectrophotometric Method

GB/T 223.31 Iron, Steel and Alloy - Determination of Arsenic Content - Distillation-molybdenum Blue Spectrophotometric Method

GB/T 223.59 Iron, Steel and Alloy - Determination of Phosphorus Content - Bismuth Phosphomolybdate Blue Spectrophotometric Method and Antimony Phosphomolybdate Blue Spectrophotometric Method

GB/T 223.64 Iron, Steel and Alloy - Determination of Manganese Content - Flame Atomic Absorption Spectrometric Method

GB/T 228.1-2010 Metallic Materials - Tensile Testing - Part 1: Method of Test at Room Temperature

GB/T 230.1 Metallic Materials - Rockwell Hardness Test - Part 1: Test Method

GB/T 247 General Rule of Package Mark and Certification for Steel Plates (sheets) and Strips

GB/T 708 Dimension, Shape, Weight and Tolerance for Cold-rolled Steel Plate

GB/T 2520 Cold-reduced Electrolytic Tinplate

GB/T 2523 Measuring Method of Surface Roughness and Peak Count for Cold-rolled Metal Sheet (strip)

GB/T 4336 Standard Test Method for Spark Discharge Atomic Emission Spectrometric Analysis of Carbon and Low-alloy Steel (routine method)

GB/T 6730.79 Iron Ores - Determination of Cadmium Content - Hydride Generation - Atomic Fluorescence Spectrometric Method

GB/T 8170 Rules of Rounding off for Numerical Values & Expression and Judgement of Limiting Values

GB/T 16597 Analytical Methods of Metallurgical Products - General Rule for X-ray Fluorescence Spectrometric Methods

GB/T 17505 Steel and Steel Products - General Technical Delivery Requirements

GB/T 20066 Steel and Iron - Sampling and Preparation of Samples for the Determination of Chemical Composition

GB/T 20123 Steel and Iron - Determination of Total Carbon and Sulfur Content - Infrared Absorption Method after Combustion in an Induction Furnace (routine method)

GB/T 20125 Low-alloy Steel - Determination of Multi-element Contents - Inductively Coupled Plasma Atomic Emission Spectrometric Method

6 Dimensions, Shapes and Weights

6.1.3 In terms of steel strip, the dimensions are expressed in thickness x width in millimeters (mm). The letter C may also be added after the number indicating the rolling width. Example: 0.26 x 832C.

6.1.4 The inner diameter of steel coils is 406 mm, 420 mm, 450 mm or 508 mm.

6.2 Permissible Deviations for Dimensions

6.2.1 Thickness

6.2.1.1 The thickness of steel sheet and strip shall satisfy the following requirements:

a) The deviation of thickness measured at the centerline position in the width direction from the nominal thickness shall not exceed ± 5% of the nominal thickness.

b) The deviation of thickness measured at a position not less than 6 mm from the side in the width direction from the nominal thickness is -8% ~ +5% of the nominal thickness.

c) When the quantity of delivery is greater than 10,000 pieces of steel sheet (or steel coils of equal length), the permissible deviation between the average thickness of all steel sheets and the nominal thickness shall not exceed ± 2% of the nominal thickness.

6.2.1.2 The measurement of thickness is carried out with a micrometer with an accuracy of 0.001 mm. The measurement result shall be rounded off to 0.001 mm. The thickness measurement position is any point not less than 6 mm from the side in the width direction.

6.2.2 Thin edge

6.2.2.1 Thin edge is the thickness change of steel sheet and strip along the width direction. It is characterized by thickness reduction occurring near the edge of steel sheet and strip. The deviation between the thickness measured at 6 mm from both sides of the width direction of the steel sheet and strip and the actual thickness measured along the centerline of the width direction of the steel sheet and strip shall not exceed 6.0% of the actual thickness measured at the centerline position.

6.2.2.2 In terms of the measurement of thin edge, use a micrometer to measure 3 points on the same straight line perpendicular to the rolling direction. The 3 measured points are located along the straight line and respectively at the center of the width and 6 mm from the two rolling width cutting edges.

6.2.3 Width

8 Test Methods

8.3 For the hardness test, a sample is usually determined at 3 points. When the range of the 3 points (namely, the difference between the maximum value and the minimum value) is greater than 1.0, then, 2 additional points shall be added to the determination. Then, remove the maximum value and the minimum value of the 5 points; calculate the average value of the 3 points as the test value. When objections are raised to the determination result, remove the chromium-plated coating, then, re-determine it. If objections are raised to the determined value due to the affect of surface roughness, grind the sample surface, then, re-determine it.

8.4 When the nominal thickness of steel sheets and strips is less than 0.20 mm, the determination of hardness shall adopt HR15TSm, then, convert it to HR30TSm in accordance with the stipulations of Appendix D.

9 Inspection Rules

9.1 The inspection and acceptance inspection of steel sheets and strips shall be carried out by the supply-side's quality inspection department.

9.2 Steel sheets and strips shall be inspected in batches. Each inspection batch shall be constituted of steel sheets or strips of the same designation, the same specification and the same surface status. The weight of each batch shall not exceed 60 t.

9.3 The sampling size and sampling location of each batch of steel sheets and strips shall comply with the stipulations of Table 8.

9.4 The re-inspection of steel sheets and strips shall comply with the stipulations of GB/T 17505.

9.5 The inspection results of chemical composition and mechanical properties shall be rounded off through the value rounding-off and comparison method. The value rounding-off rules shall comply with the stipulations of GB/T 8170.

10 Packaging, Marking and Quality Certificate

The packaging, marking and quality certificate of steel sheets and strips shall comply with the stipulations of GB/T 247.

Appendix A (normative) Rebound Test Method for Secondary Cold-reduced Sheet

A.1 Principle

Firstly, measure the thickness of the rectangular test piece. Make a 180° bend around the cylindrical mandrel, then, loosen it to measure the rebound angle. It provides a simple and convenient method for the evaluation of the yield strength of secondary cold-reduced sheet.

A.2 Sample

From each piece of sample steel sheet of secondary cold-reduced electrolytic chromium coated sheet, along the rolling direction at the edge and in the middle, take two 200 mm x 25 mm samples. The distance between the edge sample and the edge of the steel sheet is not less than 25 mm.

A.3 Test

A.3.1 Test instrument

Rebound tester.

A.3.2 Test Procedures

A.3.2.1 Measure the thickness of the sample, accurate to 0.001 mm.

A.3.2.2 Insert the sample into the rebound tester. Use moderate pressure to tighten the clamping screw; fix the sample in the test position.

A.3.2.3 Stably swing the builder arm, so that the sample is bent 180° around the axis.

A.3.2.4 Return the builder arm to the starting position. Along the sample, directly observe, read and record the rebound angle. Then, remove the sample.

A.3.2.5 In accordance with the measured value of the sample thickness and the rebound angle, on the nomogram matched with the rebound tester, measure the rebound index (SBI).

A.3.2.6 In order to ensure the accuracy of the test results, a standard sample or another reference rebound tester shall be used to calibrate the rebound tester being used.

A.4 Test Result Report

Appendix B (normative) Test Method for the Amount of Metal Chromium Coating on the Surface of Chromium Coated Sheet

B.4.1.2

B.4.1.2.8 NaNO2 solution (2 g/L): weigh-take 0.2 g of analytically pure sodium nitrite; dissolve it in 100 mL of deionized water.

B.4.1.2.9 Urea solution (200 g/L): weigh-take 20 g of analytically pure urea; use deionized water to dissolve it and reach a constant volume of 100 mL.

B.4.1.2.10 Diphenylcarbazide solution (2.5 g/L): weigh-take 0.25 g of diphenylcarbazide; dissolve it in 100 mL of analytically pure acetone. This reagent should be prepared for immediate use.

B.4.1.2.11 Hexavalent chromium standard solution (1,000 mg/L): a commercially available national standard solution.

B.4.1.2.12 Hexavalent chromium standard solution (10 mg/L): use a transfer pipette to accurately dispense 10.0 mL of hexavalent chromium standard solution (1,000 mg/L); reach a constant volume in a 1,000 mL volumetric flask. […]

B.4.1.3 Operating procedures

B.4.1.3.1 Add 25 mL of NaOH solution (40 g/L) to a conical flask. Add 1 drop of phenolphthalein (1%) indicator; use H2SO4 solution (1+3) to titrate it, until the red color of the indicator just fades. Then, record the volume of the consumed sulfuric acid VH2SO4 (mL).

B.4.1.3.2 Take an appropriate amount of NaOH solution (300 g/L); on an electric heating plate or electric furnace, heat it up to 90 °C. Then, put the sample into it. Maintain it immersed and heated for 5 min ~ 10 min. Dissolve it to remove the chromium oxide coating on the surface of the sample.

B.4.1.3.3 Take out the sample which has the chromium oxide coating peeled off. Put it into the electrolysis device as shown in Figure B.1. Take the sample as an anode. Add 25 mL of NaOH solution (40 g/L) as the electrolytic solution. At the current density of 0.4 mA/cm2 ~ 2.5 mA/cm2, carry out electrolysis at room temperature. When small bubbles emerge from the sample, stop the electrolysis.

B.4.1.3.4 Transfer all the electrolyte to a 100 mL volumetric flask. Rinse the sample, the electrode and electrolytic cell. Incorporate all the rinsing fluid into the volumetric flask. Add the H2SO4 solution (1+3) VH2SO4 (mL) obtained through the test in B.4.1.3.1. Use deionized water to reach a constant volume to the scale, then, shake it well.

NOTE: since alkali will corrode glass container, and the dispensed test solution consumes about 0.5 mL of H2SO4 solution (1+3), it is quite difficult to adjust the acidity. Meanwhile, neutral solution makes it easy for dispensing and rinsing.

B.4.1.3.5 From the above-mentioned constant-volume electrolyte, dispense 20.0 mL […]

B.4.3 X-ray fluorescence method
B.4.3.1 Instrument

X-ray fluorescence instrument that complies with the requirements of GB/T 16597.

B.4.3.2 Instrument conditions

The target material of the X-ray tube shall be made of materials suitable for the determination of metal chromium. The setting of tube voltage and tube current shall consider the lowest excitation voltage of X-ray fluorescence and the counting loss of the determination. The selection of slits, spectroscopic crystals and detectors shall consider the transition energy of the X-ray fluorescence being determined and the measurement range of chromium element.

B.4.3.3 Operating procedures

B.4.3.3.1 Take an appropriate amount of NaOH solution (300 g/L); on an electric heating plate or electric furnace, heat it up to 90 °C. Then, put the sample into it. Maintain it immersed and heated for 5 min ~ 10 min. Dissolve it to remove the chromium oxide coating on the surface of the sample.

B.4.3.3.2 Correctly place the above-mentioned sample in the sample box of the X-ray fluorescence instrument. Use the set instrument conditions to irradiate the test piece with X-ray fluorescence, so as to determine the X-ray fluorescence intensity of chromium.

B.4.3.3.3 Immerse the above-mentioned sample into H2SO4 solution (1+3) for 3 min ~ 5 min, so as to completely remove the metal chromium on the surface of the sample.

Appendix C (normative) Test Method for the Amount of Chromium Oxide Coating on the Surface of Chromium Coated Sheet

C.1 General Rules

This Appendix applies to the detection of the amount of chromium oxide coating on the surface of chromium coated sheet.

C.2 Outline

This Appendix includes the following three test methods:

--- Diphenylcarbazide spectrophotometric method: immerse the chromium-plated sample in a hot sodium hydroxide solution to dissolve the chromium oxide coating on the lower surface. After oxidizing the chromium in the solution to hexavalent chromium, use diphenylcarbazide for chromogenic reaction. Use a spectrophotometer to determine the absorbance, so as to obtain the amount of chromium oxide coating of the sample.

---X-ray fluorescence method: firstly, determine the X-ray fluorescence intensity of chromium on the surface of the sample, then, immerse the chromium-plated sample in a hot hydroxide solution to remove the chromium oxide coating on the surface. Then, determine the X-ray fluorescence intensity of the sample.

Through the difference between the two intensities, calculate the amount of chromium oxide coating of the sample.

--- Electrolytic stripping method: in phosphate buffer solution, through the constant electrolysis current, oxide the sample to generate a potential jump. Measure the electrolysis time. Through the working curve, calculate the amount of chromium oxide.

C.3 Sample

The sample to be tested is square or circular. Specifically speaking, the stripping area of the diphenylcarbazide spectrophotometric method and the electrolytic stripping method is not less than 700 mm²; for the sample of the X-ray fluorescence method, the area irradiated by X-ray fluorescence is not less than 700 mm².

C.4 Test Methods

C.4.1 Diphenylcarbazide spectrophotometric method
C.4.1.1 Instruments
C.4.1.2

C.4.1.2.9 Diphenylcarbazide solution (2.5 g/L): weigh-take 0.25 g of diphenylcarbazide; dissolve it in 100 mL of analytically pure acetone. This reagent should be prepared for immediate use.

C.4.1.2.10 Hexavalent chromium standard solution (1,000 mg/L): a commercially available national standard solution.

C.4.1.2.11 Hexavalent chromium standard solution (10 mg/L): use a transfer pipette to accurately dispense 10.0 mL of hexavalent chromium standard solution (1,000 mg/L); reach a constant volume in a 1,000 mL volumetric flask. […]

C.4.1.3 Operating procedures

C.4.1.3.1 Add 15 mL of NaOH solution (300 g/L) to a conical flask. Add 1 drop of phenolphthalein (1%) indicator; use H2SO4 solution (1+3) to titrate it, until the red color of the indicator just fades. Then, record the volume of the consumed sulfuric acid VH2SO4 (mL).

C.4.1.3.2 In accordance with the mode shown in Figure C.1, properly install the sample. Add 15 mL of hot NaOH solution (300 g/L), then, put the device into a water bath kettle (at 90 °C) to heat it up for 5 min ~ 10 min, until the chromium oxide coating on the surface of the sample completely dissolves.

C.4.1.3.3 Transfer all the above-mentioned dissolved solution to a beaker. Add the H2SO4 solution (1+3) VH2SO4 (mL) obtained through the test in C.4.1.3.1. Use deionized water to reach a constant volume to the scale. Then, add 3 mL of sulfur-phosphorous mixed acid.

C.4.1.3.4 Heat up and boil the test solution. Then, add 2 mL of KMnO4 solution (5 g/L). Continue to boil it for 3 min ~ 4 min to oxidize all chromium to Cr6+. After the test solution cools down, add 10 mL of urea solution (200 g/L); shake it well. Then, while stirring it, dropwise add NaNO2 solution [firstly, dropwise add NaNO2 solution (20 g/L); wait till the color of the test solution changes from dark purple red to light purple red, then, change to dropwise addition of NaNO2 solution (2 g/L)], until the test solution becomes colorless and transparent.

C.4.1.3.5 Transfer the above-mentioned test solution to a 100 mL volumetric flask. Use deionized water to dilute it to about 80 mL. Thoroughly shake the test solution in the volumetric flask; drive off the gas in the test solution. Add 3 mL of diphenylcarbazide solution (2.5 g/L), shake it well, so that the chromogenic reaction of the test solution manifests light red. Then, use deionized water to reach a constant volume to the scale.

C.4.1.3.6 After the above-mentioned test solution is placed still for 2 min, use a spectrophotometer to measure the absorbance at 540 nm. From the calibration curve prepared on the spectrophotometer, measure the chromium content (mg/100 mL) of the test solution. […]

C.4.2

C.4.2.3.2 Take an appropriate amount of NaOH solution (300 g/L); on an electric heating plate or electric furnace, heat it up to 90 °C. Then, put the above-mentioned sample into it. Maintain it immersed and heated for 5 min ~ 10 min. Dissolve it to remove the chromium oxide coating on the surface of the sample.

C.4.2.3.3 Correctly place the above-mentioned sample in the sample box of the X-ray fluorescence instrument. Use the set instrument conditions to irradiate the test piece with X-ray fluorescence, so as to re-determine the X-ray fluorescence intensity of chromium.

C.4.2.3.4 Calculate the difference between the above-mentioned two X-ray fluorescence intensities of chromium. On the X-ray fluorescence calibration curve that has already been prepared, obtain the amount of chromium oxide coating of the sample. […]

C.4.2.4 Drawing of calibration curve

By measuring the X-ray fluorescence intensity of a chromium-plated sheet sample with a gradient distribution of already-known metal chromium content, draw a calibration curve. By periodically measuring the X-ray fluorescence intensity of the sample used for calibration, calibrate the curve.

C.4.3 Electrolytic stripping method
C.4.3.1 Electrolysis device and electrolysis conditions

C.4.3.1.1 The electrolysis device and circuit composition are shown in Figure C.2.

C.4.3.1.2 The electrolysis conditions are as follows:

a) Electrolyte: take 15.3 g of Na2HPO4-12H2O and 2.09 g of NaH2PO4-2H2O; dissolve it in 1,000 mL of distilled water or deionized water. The pH value of this solution shall be 6 ~ 8;

b) Electrolysis temperature: normal temperature;

c) Electrolysis constant current: 50 µA/cm2. […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 44 pages — is available in the English PDF.

Referenced standards

Normative references

Similar standards

Editions of GB/T 24180

EditionTitleRevisionStatus
GB/T 24180-2020Cold-reduced electrolytic chromium/chromium oxide coated steel sheet and stripcurrent editionCurrent
GB/T 24180-2009Cold-reduced electrolytic chromium/chromium oxide coated steel sheet and stripprevious editionSuperseded

This page sells the current edition, GB/T 24180-2020. Earlier editions are listed for reference only.

How to Download GB/T 24180-2020

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
44 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 24180-2020

$385.00