Valid

SN/T 3322.1-2012Chemical analysis of limenite concentrate for import and export. Part 1: Determination of major and minor components. Wavelength dispersive X-ray fluorescence spectrometry (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (7 pages)

Need quotation for your management?

Get a formal quotation for SN/T 3322.1-2012 in 30 minutes.

Issued by

General Administration of Customs

Level / Type

National · Recommended

Issue date

December 12, 2012

Implementation date

July 1, 2013

Scope

SN/T 3322.1-2012 (Chemical analysis of limenite concentrate for import and export. Part 1: Determination of major and minor components. Wavelength dispersive X-ray fluorescence spectrometry) is available as an English-translated PDF.

SN/T 3322.1-2012 - SN/T 3322 This section specifies the method for determination of major and minor components in Titanium Concentrate by wavelength dispersive X-ray fluorescence spectrometer.

This section applies to the determination of titanium concentrates in major and minor components, measurement range (by mass) shown in Table 1.

Table 1 titanium concentrate measurement range of each component ingredient Measurement range (mass fraction) Al2O3 0.1 ~ 3.0 CaO 0.1 ~ 2.0 Fe 17.0 ~ 42.0 MgO 0.05 ~ 6.00 MnO 0.01 ~ 3.00 P 0.01 ~ 0.20 S 0.01 ~ 0.20 SiO2 0.10 ~ 5.00 TiO2 35.0 ~ 60.0 V2O5 0.02 ~ 0.50

Found what you need?

Document preview — SN/T 3322.1-2012

National Standard of the People's Republic of China

Classification
D41

Issued by: General Administration of Customs

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Method summary

Foreword

This section SN/T 3322 "Importers and chemical analysis of titanium concentrate," Part 1.

This section drafted in accordance with GB/T 1.1-2009 given rules.

The section under the jurisdiction of the State Certification and Accreditation Administration Committee.

1 Scope

SN/T 3322 This section specifies the method for determination of major and minor components in Titanium Concentrate by wavelength dispersive X-ray fluorescence spectrometer.

This section applies to the determination of titanium concentrates in major and minor components, measurement range (by mass) shown in Table 1.

Table 1 titanium concentrate measurement range of each component

ingredient

Measurement range (mass fraction) Al2O3 0.1 ~ 3.0 CaO 0.1 ~ 2.0 Fe 17.0 ~ 42.0 MgO 0.05 ~ 6.00 MnO 0.01 ~ 3.00 P 0.01 ~ 0.20 S 0.01 ~ 0.20 SiO2 0.10 ~ 5.00 TiO2 35.0 ~ 60.0 V2O5 0.02 ~ 0.50

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.

GB/T 6379.2 measurement methods and results of Accuracy (trueness and precision) - Part 2. Determine the standard measurement method to repeat of the basic methods of reproduction Laboratory use specifications and test methods GB/T 6682 Analysis GB/T 16597 metallurgical product analysis X-ray Fluorescence Spectrometry General

3 Method summary

Sample was cast into a certain proportion of flux suitable for melting the sample plate X-ray fluorescence spectrometer measurements. In the selected instrument measurement bar by measuring sample pieces melt film analyte characteristic spectral lines of X-ray fluorescence intensity, based on the calibration curve, and the inter-element interference effect it should be corrected to obtain the content of the analyte.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 7 pages — is available in the English PDF.

Referenced standards

How to Download SN/T 3322.1-2012

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
7 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

SN/T 3322.1-2012

$209.00