SN/T 3093-2012Determination of sodium, aluminium, silicon, sulfur, calcium, vanadium, iron, nickel in residual fuel oil. Wavelength dispersive X-ray fluorescence spectrometry (English PDF)
This is a limited preview
Buy now to download the full PDF (7 pages)
Need quotation for your management?
Get a formal quotation for SN/T 3093-2012 in 30 minutes.
Issued by
General Administration of Customs
Level / Type
National · Recommended
Issue date
May 7, 2012
Implementation date
November 16, 2012
Scope
SN/T 3093-2012 (Determination of sodium, aluminium, silicon, sulfur, calcium, vanadium, iron, nickel in residual fuel oil. Wavelength dispersive X-ray fluorescence spectrometry) is available as an English-translated PDF.
SN/T 3093-2012 - This standard specifies the residual fuel oil in sodium, aluminum, silicon, sulfur, calcium, vanadium, iron, nickel content - Wavelength dispersive X-ray fluorescence spectrometry method.
This standard applies to water less than 0.5% of residual fuel oil, the measurement range as shown in Table 1. Table 1 Measuring range element Measuring range mg/kg Na 12 ~ 100 Al 3 ~ 100 Si 3 ~ 100 S 5000 ~ 40000 Ca 2 ~ 100 V 2 ~ 200 Fe 2 ~ 200 Ni 2 ~ 200
Found what you need?
Document preview — SN/T 3093-2012
National Standard of the People's Republic of China
- ICS
- 75.160.20
- Classification
- E31
Issued by: General Administration of Customs
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Method summary
- 4 Reagents and materials
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
This standard is proposed and managed by the National Certification and Accreditation Administration Committee.
This standard was drafted. People's Republic of China Ningbo Exit Inspection and Quarantine.
1 Scope
This standard specifies the residual fuel oil in sodium, aluminum, silicon, sulfur, calcium, vanadium, iron, nickel content - Wavelength dispersive X-ray fluorescence spectrometry method.
This standard applies to water less than 0.5% of residual fuel oil, the measurement range as shown in Table 1.
Table 1 Measuring range
element
Measuring range
mg/kg
Na 12 ~ 100
Al 3 ~ 100
Si 3 ~ 100
S 5000 ~ 40000
Ca 2 ~ 100
V 2 ~ 200
Fe 2 ~ 200
Ni 2 ~ 200
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 6379.1 measurement methods and results of Accuracy (trueness and precision) - Part 1. General principles and definitions GB/T 6379.2 measurement methods and results of Accuracy (trueness and precision) - Part 2. Determine the weight of a standard measurement method Refolding and basic methods of reproduction GB/T 16597 metallurgical product analysis X-ray Fluorescence Spectrometry General
3 Method summary
Measuring the intensity of X-ray fluorescence sample analyte characteristic spectral lines, according to a given X-ray fluorescence intensity and analyte content between Volume relationship, the choice of methods and mathematical regression calibration mode, calculate the amount of analyte.
4 Reagents and materials
4.1 White Oil (light paraffin oil), the elemental sulfur is less than 1mg/kg, less than the other tested elements 0.05mg/kg.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 7 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 6379.1Accuracy (trueness and precision) of measurement methods and results -- Part 1: General principles and definitions
- GB/T 6379.2Accuracy (trueness and precision) of measurement methods and results - Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method
- GB/T 16597Analytical methods of metallurgical products—General rule for X-ray fluorescence spectrometric methods
How to Download SN/T 3093-2012
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 16597-2019 — Analytical methods of metallurgical products—General rule for X-ray fluorescence spectrometric methods
GB/T 6379.1-2004 — Accuracy (trueness and precision) of measurement methods and results -- Part 1: General principles and definitions
GB/T 6379.2-2004 — Measurement methods and results -- Accuracy (trueness and precision) -- Part 2: Determine the standard methods of measurement repeatability and reproducibility of the basic method