GB/T 5917.1-2008Determination for feed particle size - Two-sieve screening method (English PDF)
饲料粉碎粒度测定 两层筛筛分法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 5917.1-2008 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
August 1, 2008
Implementation date
November 1, 2008
Scope
GB/T 5917.1-2008 is the English-translated version of 饲料粉碎粒度测定 两层筛筛分法.
GB/T 5917.1-2008 is the Chinese standard "Determination for feed particle size -- Two-sieve screening method". Its scope clause reads: This part of GB/T 5917 specifies the two-sieve screening method for the determination of the particle size of feed pulverization.
This part applies to the determination of the crushed particle size of compound feed, concentrated feed, concentrate supplement, additive premixed feed, and single feed, and can also be used for the determination of the crushed particle size of feed additives.
Its clauses include principles; instruments; sampling; measurement steps; calculation and presentation of results; allowable errors. It was issued by the General Administration of Quality Supervision, Inspection and Quarantine on AUGUST 1, 2008 and took effect on NOVEMBER 1, 2008.
Found what you need?
Document preview — GB/T 5917.1-2008
National Standard of the People's Republic of China
- ICS
- 65.120
- Classification
- B 46
- Replacing
- GB/T 5917-1986
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- 1 Scope5
- 2 Normative references5
- 3 Principles5
- 4 Instruments5
- 5 Sampling6
- 6 Measurement steps6
- 7 Calculation and presentation of results7
- 8 Allowable errors7
Foreword
GB/T 5917 "Determination for feed particle size" contains two parts, Part 1 is the "Two-sieve screening method", and Part 2 is the "Geometric average particle size method".
This part is Part 1 of GB/T 5917.
This Part replaces GB/T 5917-1986 "Determination for formula feed particle size".
Compared with GB/T5917-1986, the main changes in this part are as follows:
--- The name of the standard is changed to "Determination of feed particle size - Two-sieve screening method";
--- A foreword is added;
--- The scope of application of the standard is expanded to compound feeds, concentrated feeds, concentrate supplements, additive premix feeds, single feeds, feed additives, etc.;
--- GB/T 6005, GB/T 6003.1, and GB/T 14699.1-2005 are cited;
--- It is stipulated that the quality of the test sieve shall meet the requirements of GB/T 6005 and GB/T 6003.1;
--- It is stipulated that "according to the quality requirements of different feed products and single feed, two standard test sieves of corresponding specifications, a blind sieve (bottom sieve), and a sieve cover shall be selected";
--- The amplitude, vibration frequency, and sieving movement mode of the electric vibrating sieve machine are specified;
--- The determination steps are modified and the working conditions of manual sieving are stipulated;
--- It is stipulated that the sieving method with an electric vibrating sieve machine is the arbitration method;
--- The requirement that the allowable error of the twice tests shall not exceed 1% is changed to "the error of twice tests of the mass of undersize material of the second-layer sieve shall not exceed 2%";
1 Scope
This part of GB/T 5917 specifies the two-sieve screening method for the determination of the particle size of feed pulverization.
This part applies to the determination of the crushed particle size of compound feed, concentrated feed, concentrate supplement, additive premixed feed, and single feed, and can also be used for the determination of the crushed particle size of feed additives.
2 Normative references
The provisions in the following documents become the provisions of this part through reference in this part of GB/T 5917. For the dated references, the subsequent amendments (excluding corrections) or revisions do not apply to this part, however, parties who reach an agreement based on this part are encouraged to study if the latest versions of these documents are applicable. For undated references, the latest edition of the referenced document applies to this part.
GB/T 6003.1 Test sieves - Technical requirements and testing - Part 1: Test sieves of metal wire cloth
GB/T 6005 Test sieves - Metal wire cloth, perforated metal plate and electroformed sheet - Nominal sizes of openings
GB/T 14699.1-2005 Animal feeding stuffs - Sampling
3 Principles
The specified standard test sieves are used to sieve the sample on the vibrating sieve machine or manually, the mass of the material remaining on each layer of sieve is measured, and then its percentage in the total mass of the sample is calculated. […]
4 Instruments
4.1 Standard test sieve.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
Cited by
- GB 7300.1301-2025Feed additives - Part 13: Others - Bile acid
- GB 7300.306-2025Feed additive - Part 3: Minerals and their complexes (or chelates) - Chromium nicotinate
- GB 7300.307-2025Feed additives - Part 3: Minerals and their complexes (or chelates) - Zinc glycinate complex
- GB 7300.308-2025Feed additives - Part 3: Minerals and their complexes (or chelates) - Zinc threoninate chelate
- GB 7300.309-2025Feed additives - Part 3:Minerals and their complexes (or chelates) - Ferrous lactate
- GB 7300.312-2025Feed additives - Part 3:Minerals and their complexes (or chelates) - Tricalcium phosphate
Similar standards
Editions of GB/T 5917.1
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 5917.1-2008 | Determination for feed particle size - Two-sieve screening method | current edition | Current |
| GB/T 5917-1986 | Determination for feed particle size - Two-sieve screening method | previous edition | Superseded |
This page sells the current edition, GB/T 5917.1-2008. Earlier editions are listed for reference only.
How to Download GB/T 5917.1-2008
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 14699.1-2005 — Feeding stuffs -- Sampling
GB/T 6003.1-2022 — Test sieves—Technical requirements and testing—Part 1:Test sieves of metal wire cloth
GB/T 6005-2008 — Test sieves -- Metal wire cloth, perforated metal plate and electroformed sheet -- Nominal sizes of openings
Secure payment via Stripe
Payments accepted
GB/T 5917.1-2008
$70.00