Scope
GB/T 37078-2018 is the English-translated version of 出入口控制系统技术要求.
GB/T 37078-2018 is the Chinese technical specification for access control systems used for security, which authorize, identify and control people or items passing through access control points.
It covers the system composition and application modes, security levels, functional and performance requirements - control, indication, identification, duress, priority control, communication, self-protection, power supply and lightning protection - and the safety, electromagnetic compatibility, reliability and environmental adaptability requirements, together with marking and documentation.
Annexes give system conceptual models and typical applications, timing diagrams and equipment identification. It applies to stand-alone access control systems and to those built into other electronic systems, and can serve as a basis for their design, inspection and acceptance. It was issued on 28 December 2018 and has applied since 1 July 2019.
Found what you need?
Document preview — GB/T 37078-2018
National Standard of the People's Republic of China
- ICS
- 13.310
- Classification
- A 91
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms, definitions, abbreviations and symbols
- 3.1 Terms and Definitions
- 3.2 Abbreviations
- 3.3 Symbol
- 4 system composition and application mode
- 4.1 Concept Model
- 4.2 System Composition
- 5 security level
- 5.1 General requirements
- 5.2 Division of security levels
- 6 Functional and performance requirements
- 6.1 Control Requirements
- 6.2 Instruction/Notice Request
- 6.3 Identification requirements
- 6.4 Stress
- 6.5 Priority Control Function Requirements
- 6.6 Communication requirements
- 6.7 System Self Protection Requirements
- 6.8 Power Requirements
- 6.9 Lightning protection grounding requirements
- 7 Security requirements
- 8 Electromagnetic Compatibility Requirements
- 9 Reliability requirements
- 9.1 Operational reliability
- 9.2 Functional Reliability
- 9.3 System Reliability
- 10 Environmental adaptability requirements
- 10.1 Environmental Category
- 10.2 Adaptability requirements
- 11 logo
- 12 files available
- 12.1 Information provided with the device
- 12.2 System Files
- 12.3 Device File
- Appendix A (informative) System conceptual model and typical application model
- Appendix B (Normative Appendix) Timing Diagram
- Appendix C (Normative) Equipment Identification
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
1 Scope
This standard specifies the composition and application mode of the entrance and exit control system, safety level, functional and performance requirements, safety requirements, and electromagnetic Capacitive requirements, reliability requirements, environmental adaptability requirements, signs and documentation.
This standard applies to separate access control systems for the purpose of security, for the authorization, identification and control of specified targets;
Applicable to the access control system included in other electronic systems.
Note: This standard can be used as the basic basis for the design, inspection and acceptance of the entrance and exit control system.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this document. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 4208-2017 enclosure protection grade (IP code)
GB/T 15211 safety and alarm equipment environmental adaptability requirements and test methods
GB/T 15408 safety protection system power supply technical requirements
GB 16796 Safety and security alarm equipment safety requirements and test methods
GB/T 20138 Protection level of external mechanical collision of electrical equipment casing (IK code)
GB/T 30148 safety protection alarm equipment electromagnetic compatibility immunity requirements and test methods
GB 50343 lightning protection technical specification for building electronic information systems
GB 50348 Safety Engineering Technical Specifications
GA/T 670 Technical requirements for lightning surge protection of safety protection system
3 Terms, definitions, abbreviations and symbols
3.1 Terms and definitions
The following terms and definitions apply to this document.
3.1.1 Portal; access control point
Used to release controlled physical access ports that are authorized to reject unauthorized persons and/or items.
3.1.2 Access control system
Using the custom coded information identification and/or mode feature information recognition technology to control the opening and closing of the device by controlling the access control point, An electronic system that implements operations such as release, rejection, recording, and warning of the entry and exit of the target at the entrance and exit.
Note: Commonly known as the access control system.
3.1.3 Controlled area; protected area
A spatial region defined by physical boundaries with one or more access control points.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 27 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 4208-2017Degrees of protection provided by enclosures (IP code)
- GB/T 15211Security alarm equipment -- Environmental adaptability requirements and test methods
- GB/T 15408Technical requirement of power-supply for security & protection system
- GB 16796Security alarm equipment - Safety requirements and test methods
- GB/T 20138Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code)
- GB/T 30148Security alarm equipment -- EMC immunity requirements and test methods
Cited by
- GA 1812.1-2024Requirements for counter-terrorism of bank system - Part 1: RMB issuance vaults
- GA 1812.2-2024Requirements for counter-terrorism of bank system - Part 2: Data center
- GA 1812.3-2024Requirements for counter-terrorism of bank system - Part 3: Banknote printing and minting enterprise
- GA/T 701-2024Security protection - Fingerprint recognition applications - General specification for access control fingerprint recognition modules
- GA/T 761-2024Technical specifications for security management system in parking lots
- GA/T 1093-2023Security protection - Face recognition applications - Technical requirements for face recognition for access control
Similar standards
How to Download GB/T 37078-2018
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GA/T 670-2006 — Specification of lightning-surge protection for security and protection system
GB 16796-2022 — Security alarm equipment - Safety requirements and test methods
GB 50343-2012 — Technical code for protection of building electronic information system against lightning
Secure payment via Stripe
Payments accepted
GB/T 37078-2018
$475.00