GA 38-1992Security requirements for banking business area (English PDF)
This is a limited preview
Buy now to download the full PDF (27 pages)
Need quotation for your management?
Get a formal quotation for GA 38-1992 in 30 minutes.
Issued by
Ministry of Public Security
Level / Type
National · Mandatory
Issue date
January 1, 1970
Implementation date
January 1, 1970
Scope
GA 38-1992 (Security requirements for banking business area) is available as an English-translated PDF.
GA 38-1992 — This document specifies the overall security requirements and business premises, self-service equipment, self-service banking, business warehouses, and custody of banking financial institutions.
Safety precaution requirements for key precaution places and locations such as box warehouses, networked monitoring centers, data centers, data rooms, equipment rooms, etc. This document is applicable to the construction and management of the security protection system of banking financial institutions, and the related security of other financial institutions and security escort companies.
The construction and management of the total prevention system can be implemented by reference.
Found what you need?
Document preview — GA 38-1992
National Standard of the People's Republic of China
- ICS
- 13.310
- Classification
- A 91
Issued by: Ministry of Public Security
Contents
- Foreword
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Key prevention sites and parts
- 5 General requirements
- 6 Security requirements for bank business premises
- 7 Bank self-service equipment, self-service banking security requirements
- 8 Security requirements for banking business libraries
- 9 Security requirements for safe deposit boxes
- 10 Security requirements for networked monitoring centers
- 11 Data center, data room, equipment room security requirements
- Appendix A (Normative) Requirements for Bank Security Facilities Configuration
- Appendix B (normative) Technical requirements for explosion-proof membrane
- Appendix C (Normative) Requirements for the protection of other forms of cabinets in the cash zone and acceptance requirements for counters
- Appendix D (Informative) Security Inspection Plan
Foreword
This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1: Structure and Drafting Rules of Standardization Documents" Drafting.
This document replaces GA 38-2015 "Security requirements for bank business premises", GA 745-2017 "Bank self-service equipment, self-service banking Security Requirements", GA 858-2010 "Security Requirements for Banking Business Databases", partially replacing GA 1003-2012 "Bank self-service Wuting Security Requirements", GA 1280-2015 "Automated Teller Machine Security Requirements", compared with the above documents, except for structural adjustments and editing in addition to the sexual changes, the main technical changes are as follows.
1) Added some terms (see 3.1, 3.3, 3.12.2, 3.12.3, 3.12.4, 3.13, 3.14, 3.16, 3.19, 3.20);
2) Some terms have been changed (see 3.12, 3.12.1, 3.21, 3.22, 3.2, 3.1 of GA 858-2010, 3.5, 3.11 of GA 38-2015);
3) Some terms have been deleted (see 3.8 and 3.12 of GA 38-2015 and 3.3 of GA 745-2017);
4) The construction principle is changed (see 5.1, 4.1.1 of GA 38-2015 and 5.1.1 of GA 858-2010);
5) Changed the site selection requirements (see 5.2, 5.1 of GA 745-2017 and 5.1.3 of GA 858-2010);
6) The data management requirements are changed (see 5.3, 5.1.2 of GA 858-2010);
7) Added pipeline protection requirements (see 5.5);
8) The equipment protection requirements are changed (see 5.6, 6.2.5 of GA 745-2017);
9) Added the time calibration requirements of the electronic protection system (see 5.9);
10) The main transmission channel for networked alarms has been added to give priority to the wired network, and when the main channel fails, it will automatically switch to the backup alarm channel.
Requirements [see 5.12e)];
11) The requirements for the storage time of business database intrusion and emergency alarm system information are changed [see 5.12g), GA 858-2010 5.3.2.9];
12) Added the requirement that the anti-theft alarm controller should be installed in the protective area and have anti-vandalism alarm function [see 5.12h)];
13) Deleted the requirement that the on-site sound and light alarm device can be activated when the alarm device is activated (see 4.3.2.7 of GA 38-2015);
14) Changed the permission management requirements for image browsing, playback and download [see 5.13f), GA 858-2010, 5.3.3.2];
15) Deleted the requirement that cameras can be installed in other areas according to the site conditions [GA 38-2015 4.3.3.1f)];
16) Changed the storage time requirements of the video image information of the business library [see 5.13h), GA 858-2010 5.3.3.11];
17) Changed the storage time requirements for voice review intercom information in the business database (see 5.15, GA 858-2010, 5.3.5.3);
18) Added the safety requirements of the entrance and exit control system [see 5.14a)~c)];
19) Add the requirements for the time deviation of video and audio synchronization (see 5.15);
20) Added requirements for explosion-proof security inspection system (see 5.16);
21) Added the requirement of not handling cash and other businesses manually in the non-cash area (see 6.1.3);
22) Deleted the requirement that a toilet should be installed in the cash area of the business place (see 4.1.5 of GA 38-2015);
23) The requirement for the outer wall of the business premises has been deleted (see 4.2.1.1 of GA 38-2015);
24) The requirements for the adjacent walls of the business premises and the outside world have been changed (see 6.2.1.1.1, 4.2.1.2 of GA 38-2015);
25) The height requirement of the glass curtain wall is changed (see 6.2.1.1.2, 4.2.1.2 of GA 38-2015);
26) Added the performance requirements of the explosion-proof membrane [see 6.2.1.1.2d), 6.2.2.2d) and Appendix B];
27) Changed the wall requirements of the cash business area (see 6.2.1.2.2, 4.3.1.3.2 of GA 38-2015);
28) The requirements for rolling shutter doors are changed (see 6.2.2.1, 7.3.3b), 4.2.2.1, 4.4.1a) of GA 38-2015 and GA 745-2017 6.3b)];
29) The strengthening requirements for windows below 5m in height difference between the bank's business premises and the outside ground, platform or aisle have been changed (see 6.2.2.2, 4.2.2.2 of GA 38-2015);
30) The length and installation requirements of steel plate structure counters have been changed [see 6.2.3.1b), GA 38-2015 4.2.3.1b)];
31) Changed the performance requirements of the transparent protective plate [see 6.2.3.2a), GA 38-2015 4.2.3.2a)];
32) The requirements for the protective steel plate of the cash register are changed [see 6.2.3.3c), 4.2.3.3c) of GA 38-2015];
33) The overall protection performance requirements of the counter are changed (see 6.2.3.4, 4.2.3.4 of GA 38-2015);
34) Added the requirement that the anti-following linkage interlocking safety door channel does not have access to other areas (see 6.2.4);
35) Added the requirements for the installation of access control devices at the entrances and exits of the cash business area and the office area that communicate with the outside world (see 6.3.3)
36) Added the requirements for the installation of sound review devices in the connection channels of the customer activity area and the anti-following linkage interlocking safety door (see 6.3.4.2);
37) Deleted the requirement of installing sound review device in the cash adding area of self-service equipment (see 4.3.5.3 of GA 38-2015);
38) Deleted the remote teller system requirements (see 4.4.4 of GA 38-2015);
39) Added environmental illumination requirements for customer operating areas of bank self-service equipment (see 7.2.6);
40) Added the requirement that non-cash bank self-service equipment is not installed on the wall of the cash adding room (see 7.3.2.3);
41) The installation position and requirements of the upper and lower box intrusion detectors of cash bank self-service equipment have been changed (see 7.4.1.1, GA 745-2017's 7.1.1);
42) Deleted the requirement that the self-service equipment add money area should install a sound review device (see 4.3.5.3 of GA 38-2015);
43) The location requirements of freight elevators and stairs in the business warehouse have been changed (see 8.2.2, 5.1.6 of GA 858-2010);
44) The requirements for the prevention and control isolation door are changed (see 8.2.4, 5.2.1.10 of GA 858-2010);
45) The physical protection requirements for the guard room and the clearing of the whole point have been added (see 8.2.5);
46) Added the requirement that any form of cash replenishment room, bank self-service equipment, cabinets, etc. cannot be used in place of the business library (see 8.2.6);
47) Added the protection requirements for the air supply and exhaust device of the banking warehouse (see 8.3.1.5);
48) The construction requirements of the four types of warehouses for business warehouses have been changed (see 8.3.4.1, 5.2.4.1 of GA 858-2010);
49) Added the requirements for the installation of prevention and control isolation doors in the four types of business warehouses in remote warehouses (see 8.3.4.3);
50) The requirements for installing vibration detectors on the walls of the warehouse and the inner walls of the corridor have been added (see 8.4.1.2);
51) Added the requirement of installing emergency alarm devices between the whole points of the sorting (see 8.4.1.3);
52) Added the requirement that two independent defense zones should be set up inside and outside the prevention and control isolation door of business libraries above three categories (see 8.4.1.4);
53) The requirements for the installation of entrance and exit control devices for the entrances and exits that communicate with the outside world and the prevention and control isolation doors in the business library have been added (see 8.4.3.1);
54) Added the requirement of installing a full-duplex mode voice intercom device on the prevention and control isolation door (see 8.4.4.1);
55) Added requirements for the installation of sound review devices in areas such as warehouses, guard rooms, clearing hour rooms, handover areas, loading and unloading areas, passages, and corridors (See 8.4.4.2);
56) The location requirements of the local guard room have been changed (see 8.5.1.1, 5.4.1 of GA 858-2010);
57) The requirements for walls, doors and windows of the local warehouse room have been changed (see 8.2.5, 8.5.1.2, 5.4.2, 5.4.3 of GA 858-2010);
58) Added the requirements for installing video surveillance devices inside and outside the local guardhouse (see 8.5.1.7);
59) The configuration requirements of the local guard room are changed (see 8.5.1.6, 5.4.6 of GA 858-2010);
60) Added the requirement for the local guard room to receive real-time alarm and other security information (see 8.5.1.8);
61) Added the operation requirements of the local guard room for arming and disarming the defense area outside the prevention and control isolation door (see 8.5.1.9);
62) Added the requirement of a special safe for guns and ammunition in the local depot (see 8.5.1.10);
63) Changed the requirements for remote storage (see 8.5.2, 5.3.6.1 of GA 858-2010);
64) Changed the requirements for dividing the whole point interval (see 8.5.3, 5.3.3.6 of GA 858-2010);
65) Added location requirements for handover area and loading area (see 8.5.4.1, 8.5.4.2);
66) The requirements for safe deposit box warehouses have been changed (see 9.1.2, 9.1.3, 4.4.2.5 and 4.4.2.6 of GA 38-2015);
67) The requirements for installing intrusion detectors in the warehouse have been changed (see 9.2.1, 4.4.2.3 of GA 38-2015);
68) Added the requirements for the installation of entrance and exit control devices at the entrance and exit of the safe deposit box (see 9.2.3);
69) Added security requirements for networked monitoring centers (see 10);
70) Added data center security requirements (see 11.1);
71) Added data room safety precaution requirements (see 11.2);
72) Added the requirements for the wall of the equipment room (see 11.3.1);
73) The requirements for the door between the equipment have been changed (see 11.3.2, 4.4.3.1 of GA 38-2015);
74) Added the requirements for equipment rooms set up in the cash business area (see 11.3.3);
75) The requirements for windows in the equipment room have been changed (see 11.3.4, 4.4.3.2 of GA 38-2015);
76) The requirement to install air conditioning or ventilation facilities in the equipment room has been deleted (see 4.4.3.4 of GA 38-2015).
This document was submitted by the Public Security Administration of the Ministry of Public Security.
This document is under the jurisdiction of the National Standardization Technical Committee for Security and Alarm System (SAC/TC100).
Introduction
In accordance with the requirements of the national standardization reform, the Public Security Administration of the Ministry of Public Security organizes special Family's requirements for GA 38-2015 "Security Requirements for Banking Places", GA 745-2017 "Security Requirements for Bank Self-service Equipment and Self-service Banking Requirements", GA 858-2010 "Security Requirements for Banking Business Databases", GA 1003-2012 "Security Requirements for Bank Self-Service Kiosks", GA 1280-2015 "Automated Teller Machine Security Requirements" and other standards are integrated, and the integrated standard replaces GA 38-2015, GA 745-2017, GA 858-2010, partially replace GA 1003-2012, GA 1280-2015, and become mandatory for the public safety industry the standard "Bank Security Requirements" is for bank business premises, self-service equipment, self-service banking, business libraries, safe deposit boxes, networked monitoring centers, and data centers.
According to the construction, approval and acceptance, daily inspection, and safety assessment of key prevention sites and locations such as the center, data room, equipment room, etc.
in accordance with.
Bank security requirements
1 Scope
This document specifies the overall security requirements and business premises, self-service equipment, self-service banking, business warehouses, and custody of banking financial institutions.
Safety precaution requirements for key precaution places and locations such as box warehouses, networked monitoring centers, data centers, data rooms, equipment rooms, etc.
This document is applicable to the construction and management of the security protection system of banking financial institutions, and the related security of other financial institutions and security escort companies.
The construction and management of the total prevention system can be implemented by reference.
2 Normative references
The contents of the following documents constitute the indispensable clauses of this document through normative references in the text. Among them, dated quotations Only the version corresponding to that date is applicable to this document; for undated reference documents, the latest version (including all amendments) is applicable to this document.
GB/T 1499.2 Steel for reinforced concrete Part 2: Hot-rolled ribbed steel bars GB 10409 Anti-theft safe (box) GB 12899 General technical specifications for handheld metal detectors GB 15208.1 Micro-dose X-ray safety inspection equipment Part 1: General technical requirements GB 15210 General technical specification for pass-through metal detection doors GB/T 16676 Technical requirements for bank security, alarm and monitoring networking system GB 17565-2007 General technical requirements for anti-theft security doors GB/T 28181 Technical requirements for information transmission, exchange and control of public security and video surveillance networked systems GB/T 32581 Technical requirements for intrusion and emergency alarm system GB/T 37078-2018 Technical requirements for entrance and exit control system GB 37481-2019 General technical requirements for vault doors GB 50348 Security Engineering Technical Standard GA/T 73-2015 Mechanical anti-theft lock GA 165-2016 bulletproof transparent material GA/T 501 bank safe deposit box GA 576 Anti-tailing linkage interlocking safety door general technical requirements GA 667-2020 Explosion-proof transparent material GA/T 841 General technical requirements for trace narcotics/explosives detector based on ion mobility spectroscopy technology GA 844-2018 Anti-smashing transparent material GA 1051 special safe for guns and ammunition GA/T 1067 General technical requirements for liquid product safety inspection equipment based on Raman spectroscopy technology GA 1081 safety protection system maintenance specifications GA/T 1323 General technical requirements for trace explosive detector based on fluorescent polymer sensing technology GA/T 1337 Security requirements for protective cabins of bank self-service equipment GA/T 1343 Anti-riot Lifting Vehicle Blocking Barricade GA 1383 Alarm Operation Service Specification
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 27 pages — is available in the English PDF.
Referenced standards
Normative references
- GB 10409Burglary-resistant safes
- GB 12899General technical specification for hand-held metal detector
- GB 15208.1Micro-dose X-ray security inspection systems - Part 1: General technical requirements
- GB 15210General specifications for walk-through metal detectors
- GB/T 16676Specification of alarm and monitoring network system for bank security and protection
- GB 17565-2007General specifications for burglary-resistant security doors
GB/T 1499.2 · GB/T 32581
How to Download GA 38-1992
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 10409-2001 — Burglary resistant safes
GB 10409-2019 — Burglary-resistant safes
GB 12899-2018 — General specifications for hand-held metal detectors
Secure payment via Stripe
Payments accepted
GA 38-1992
$764.00