Scope
GB 10409-2001 (Burglary resistant safes) is available as an English-translated PDF.
GB 10409-2001 - This Standard specifies the classification, technical requirements, test methods inspection rules and marks, packaging, transportation, and storage of burglary resistant safes.
This Standard applies to the production and inspection of burglary resistant safes. It also applies to the burglary resistant safes that is attached with functions such as alarm, fire protection, and/or remote control.
Found what you need?
Document preview — GB 10409-2001
National Standard of the People's Republic of China
- ICS
- 13.310
- Classification
- A 91
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People’s Republic of China
Contents
- Foreword...3
- 1 Scope...4
- 2 Normative references...4
- 3 Definitions...5
- 4 Product classification and marking...6
- 5 Technical requirements...8
- 6 Test methods...12
- 7 Inspection rules...17
- 8 Marks, packaging, transportation and storage...20
Foreword
All technical contents in this Standard are mandatory.
This Standard is the revision of GB 10409-1989.
This Standard no longer specify that the burglary resistant safes must be installed with warning unit. It
classifies the safety performance of the burglary resistant safes. It does not divide the products into
qualified product, first-class products and superior products. The contents of technical requirements and
test methods of previous version have been detailed and supplemented, such as. Class A products in
the previous version were subdivided into Class A1 and Class A2; Class B products were subdivided
into Class B1, B2 and B3.It respectively specifies the gaps between cabinet door and door frame,
according to the height of cabinet. For the code-volume of the electronic lock, add the requirements of
"arbitrarily-variable code"; and requirements and test methods of "anti-electromagnetic interference".
Add the "Inspection Item Table", etc.
This Standard will replace GB 10409-1989, from its implementation date.
This Standard was proposed by the Ministry of Public Security of the People's Republic of China.
This standard shall be under the jurisdiction of Standardization Technical Committee for Security &
Protection Alarm Systems of China.
This Standard was jointly drafted by. Shanghai Diebold King Safe Co., Ltd, Product Quality Supervision,
Inspection and Test Center for Security & Protection Alarm Systems of Ministry of Public Security, and
China Security & Protection Product Industry Association Secretariat.
1 Scope
This Standard specifies the classification, technical requirements, test methods inspection rules and
marks, packaging, transportation, and storage of burglary resistant safes.
This Standard applies to the production and inspection of burglary resistant safes. It also applies to the
burglary resistant safes that is attached with functions such as alarm, fire protection, and/or remote
control.
2 Normative references
The articles contained in the following documents have become part of this Standard when they are
quoted herein. For the dated documents so quoted, all the modifications or revisions made thereafter
shall not be applicable to this Standard. For the undated documents so quoted, the latest editions shall
be applicable to this Standard.
GB/T 1720-1979 Method of test for adhesion of paint films
GB/T 6461-1986 Metallic coatings - Coatings cathodic to the substrate - Rating of electro-plated
test specimens subjected to corrosion tests
GB/T 10125-1997 Corrosion tests in artificial atmospheres - Salt spray tests
GB/T 12335-1990 Metallic coatings - Coatings anodic to the substrate - Rating of test specimens
subjected to corrosion
GB/T 15211-1994 Environmental testing for alarm systems
GB/T 15482-1995 Single sampling procedures and tables for product quality audit of small
population by attributes
GB/T 17626.2-1998 Electromagnetic compatibility - Testing and measurement techniques -
Electrostatic discharge immunity test
GB/T 17626.3-1998 Electromagnetic compatibility - Testing and measurement techniques -
Radiated, radio-frequency, electromagnetic field immunity test
GB/T 17626.4-1998 Electromagnetic compatibility - Testing and measurement techniques –
Electrical fast transient/burst immunity test
GB/T 17626.5-1999 Electromagnetic compatibility - Testing and measurement techniques - Surge
immunity test
GB/T 17626.11-1999 Electromagnetic compatibility Testing and measurement techniques Voltage
dips, short interruptions and voltage variations immunity tests
GA/T 73-1994 Thief resistant machine lock
3 Definitions
For the purpose of this standard, the following terms and definitions shall apply.
3.1 Burglary resistant safes
It refers to a kind of safes that is equipped with mechanical and electronic lock (including combination
lock, IC card lock, etc.) which can be used to resist abnormal entry under specified conditions within the
required time.
3.2 Safety class
The classification of anti-destruction capacity that the burglary resistant safes can withstand. The
classification is divided based on the duration of net working time that the burglary resistant safes can
resist to the abnormal entry, under the action of the specified destroying tools.
3.3 Entry
During the destruction resistant test, open the cabinet door of various burglary resistant safes or make
an opening not smaller than the specified area on the cabinet door or body, within the specified net
working time. Class A burglary resistant safes is 38cm2; Class B and Class C burglary resistant safes are
13cm2.
3.4 Common hand tools
Including the chisel, punch, wedge, screwdriver, hacksaw, wrench, pliers, hammer with the of weight not
more than 3.6kg, the prying tools with the length of not more than 1.5m, and general digging tools.
3.5 Portable electric tools
The electric hand drills with the bit diameter of not more than 12.5mm, the electric hammer drills with the
punch diameter of not more than 25mm and the pressure devices.
3.6 Grinding point
The grinding tools with shapes such as cone, disk, or cylinder that is driven by die grinders with the
rotate speed of 14000 r/min-22000 r/min.
The mechanical lock used in the burglary resistant safes shall comply with the requirements of GA/T 73.
5.4 Electronic lock (including IC card lock, electronic combination lock, etc.)
5.4.1 The coded number of the electronic combination lock shall not be less than 106.And the password
can be changed arbitrarily.
5.4.2 If the password is entered by key buttons, the key buttons shall not occur any failure in 6000
continuous pressing actions.
5.4.3 When the electronic combination lock are knocked by the energy of not more than 0.5J, the
mis-operation and damage phenomena shall be avoided.
5.4.4 The electronic combination lock shall have emergency opening function. And it may have multilevel
and multi-group opening passwords.
5.4.5 The password entrance of electronic combination lock shall be prompted. When it is continuously
entered with wrong password for three times or mis-operation, the electronic combination lock shall have
time-limited locking, alarm and other functions. However, after the time-limited locking and alarm, it shall
recover the correct operation and operate normally.
5.4.6 When the supply voltage of the electronic lock changes within the range of 85%-110% of the rated
voltage, the electronic lock shall be able to work normally. When the power voltage is below the specified
alarm voltage, it shall have under-voltage alarm indications. After under-voltage alarm, the power
capacity shall still meet more than 240 times of normal opening and closing of electronic lock.
5.4.7 The electronic lock shall be equipped with external power interface or emergency opening unit.
5.4.8 For the burglary resistant safes adopting electronic lock, the key parts of electronic lock shall be
protected. When the keyboard, wire, electromechanical actuators are destroyed and attacked, they shall
be able to withstand the destruction resistant test for corresponding classes of burglary resistant safes.
5.4.9 The environmental suitability of electronic lock shall comply with the requirements of A-1/2; A-2/5;
A-3/3; A-4/1; A-6/3; and A-18/3 in GB /T15211-1994.
5.4.10 The immunity requirements of the electronic lock shall meet the test requirements specified in
GB/T 17626.2 (Grade 1), GB/T 17626.3 (Grade 1), GB/T 17626.4 (Grade 1), GB/T 17626.5 (Grade 1)
and GB/T 17626.11 (Class 40, duration of 5 cycles).
5.5 Power supply
5.5.1 The power supply's power, energy consumption, environmental adaptability and safety
requirements shall satisfy the corresponding product technical requirements.
5.5.2 When the AC 220V power supply is used as the main power supply, there shall have a standby
power (a rechargeable battery or primary battery). It works normally within the range of 85%-110% of
rated voltage of the main power supply. And there shall have an overcurrent protecti...
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 20 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 1720-1979Circle-drawing test of coating films
- GB/T 6461-1986Methods for corrosion testing of metallic and other inorganic coatings on metallic substrates -- Rating of test specimens and manufactured articles subjected to corrosion tests
- GB/T 10125-1997Corrosion tests in artificial atmospheres - Salt spray tests
- GB/T 17626.2-1998Electromagnetic compatibility -- Testing and measurement techniques -- Electrostatic discharge immunity test
- GB/T 17626.3-1998Electromagnetic compatibility - Testing and measurement techniques - Part 3: Radiated, radio-frequency, electromagnetic field immunity test
- GB/T 17626.4-1998Electromagnetic compatibility -- Testing and measurement techniques -- Electrical fast transient/burst immunity test
GB/T 12335-1990 · GB/T 15211-1994 · GB/T 15482-1995
Cited by
- GB/T 45911-2025Weather modification — Safety requirements for operational ammunition storage
- GB 17565-2022General specifications for burglary-resistant security doors
- GB/T 29315-2022Security requirements for primary and secondary schools and kindergartens
- GB/T 36336.1-2018Information technology—Video teller machine—Part 1: Device
- GA 1051-2013Dedicated safes for guns and ammunition
- GB/T 16571-2012Requirements for security systems in museums and units of cultural heritage protection
How to Download GB 10409-2001
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 11118-2026 — Hydraulic fluids (L-HL, L-HM, L-HV, L-HS and L-HG type)
GB 11557-2026 — Provisions for protecting drivers from injury by the steering mechanism of motor vehicles
GB 12021.4-2026 — Maximum allowable values of the energy consumption, water consumption and grades for electric washing machines and washer-dryers
Secure payment via Stripe
Payments accepted
GB 10409-2001
$60.00