Valid

GB 10409-2001Burglary resistant safes (English PDF)

Preview PDF

Also coversGB10409-2001

This is a limited preview

Buy now to download the full PDF (20 pages)

Need quotation for your management?

Get a formal quotation for GB 10409-2001 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine of the People’s Republic of China

Level / Type

National · Mandatory

Issue date

October 24, 2001

Implementation date

April 1, 2002

Scope

GB 10409-2001 (Burglary resistant safes) is available as an English-translated PDF.

GB 10409-2001 - This Standard specifies the classification, technical requirements, test methods inspection rules and marks, packaging, transportation, and storage of burglary resistant safes.

This Standard applies to the production and inspection of burglary resistant safes. It also applies to the burglary resistant safes that is attached with functions such as alarm, fire protection, and/or remote control.

Found what you need?

Document preview — GB 10409-2001

National Standard of the People's Republic of China

ICS
13.310
Classification
A 91

Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People’s Republic of China

Contents

  • Foreword...3
  • 1 Scope...4
  • 2 Normative references...4
  • 3 Definitions...5
  • 4 Product classification and marking...6
  • 5 Technical requirements...8
  • 6 Test methods...12
  • 7 Inspection rules...17
  • 8 Marks, packaging, transportation and storage...20

Foreword

All technical contents in this Standard are mandatory.

This Standard is the revision of GB 10409-1989.

This Standard no longer specify that the burglary resistant safes must be installed with warning unit. It

classifies the safety performance of the burglary resistant safes. It does not divide the products into

qualified product, first-class products and superior products. The contents of technical requirements and

test methods of previous version have been detailed and supplemented, such as. Class A products in

the previous version were subdivided into Class A1 and Class A2; Class B products were subdivided

into Class B1, B2 and B3.It respectively specifies the gaps between cabinet door and door frame,

according to the height of cabinet. For the code-volume of the electronic lock, add the requirements of

"arbitrarily-variable code"; and requirements and test methods of "anti-electromagnetic interference".

Add the "Inspection Item Table", etc.

This Standard will replace GB 10409-1989, from its implementation date.

This Standard was proposed by the Ministry of Public Security of the People's Republic of China.

This standard shall be under the jurisdiction of Standardization Technical Committee for Security &

Protection Alarm Systems of China.

This Standard was jointly drafted by. Shanghai Diebold King Safe Co., Ltd, Product Quality Supervision,

Inspection and Test Center for Security & Protection Alarm Systems of Ministry of Public Security, and

China Security & Protection Product Industry Association Secretariat.

1 Scope

This Standard specifies the classification, technical requirements, test methods inspection rules and

marks, packaging, transportation, and storage of burglary resistant safes.

This Standard applies to the production and inspection of burglary resistant safes. It also applies to the

burglary resistant safes that is attached with functions such as alarm, fire protection, and/or remote

control.

2 Normative references

The articles contained in the following documents have become part of this Standard when they are

quoted herein. For the dated documents so quoted, all the modifications or revisions made thereafter

shall not be applicable to this Standard. For the undated documents so quoted, the latest editions shall

be applicable to this Standard.

GB/T 1720-1979 Method of test for adhesion of paint films

GB/T 6461-1986 Metallic coatings - Coatings cathodic to the substrate - Rating of electro-plated

test specimens subjected to corrosion tests

GB/T 10125-1997 Corrosion tests in artificial atmospheres - Salt spray tests

GB/T 12335-1990 Metallic coatings - Coatings anodic to the substrate - Rating of test specimens

subjected to corrosion

GB/T 15211-1994 Environmental testing for alarm systems

GB/T 15482-1995 Single sampling procedures and tables for product quality audit of small

population by attributes

GB/T 17626.2-1998 Electromagnetic compatibility - Testing and measurement techniques -

Electrostatic discharge immunity test

GB/T 17626.3-1998 Electromagnetic compatibility - Testing and measurement techniques -

Radiated, radio-frequency, electromagnetic field immunity test

GB/T 17626.4-1998 Electromagnetic compatibility - Testing and measurement techniques –

Electrical fast transient/burst immunity test

GB/T 17626.5-1999 Electromagnetic compatibility - Testing and measurement techniques - Surge

immunity test

GB/T 17626.11-1999 Electromagnetic compatibility Testing and measurement techniques Voltage

dips, short interruptions and voltage variations immunity tests

GA/T 73-1994 Thief resistant machine lock

3 Definitions

For the purpose of this standard, the following terms and definitions shall apply.

3.1 Burglary resistant safes

It refers to a kind of safes that is equipped with mechanical and electronic lock (including combination

lock, IC card lock, etc.) which can be used to resist abnormal entry under specified conditions within the

required time.

3.2 Safety class

The classification of anti-destruction capacity that the burglary resistant safes can withstand. The

classification is divided based on the duration of net working time that the burglary resistant safes can

resist to the abnormal entry, under the action of the specified destroying tools.

3.3 Entry

During the destruction resistant test, open the cabinet door of various burglary resistant safes or make

an opening not smaller than the specified area on the cabinet door or body, within the specified net

working time. Class A burglary resistant safes is 38cm2; Class B and Class C burglary resistant safes are

13cm2.

3.4 Common hand tools

Including the chisel, punch, wedge, screwdriver, hacksaw, wrench, pliers, hammer with the of weight not

more than 3.6kg, the prying tools with the length of not more than 1.5m, and general digging tools.

3.5 Portable electric tools

The electric hand drills with the bit diameter of not more than 12.5mm, the electric hammer drills with the

punch diameter of not more than 25mm and the pressure devices.

3.6 Grinding point

The grinding tools with shapes such as cone, disk, or cylinder that is driven by die grinders with the

rotate speed of 14000 r/min-22000 r/min.

The mechanical lock used in the burglary resistant safes shall comply with the requirements of GA/T 73.

5.4 Electronic lock (including IC card lock, electronic combination lock, etc.)

5.4.1 The coded number of the electronic combination lock shall not be less than 106.And the password

can be changed arbitrarily.

5.4.2 If the password is entered by key buttons, the key buttons shall not occur any failure in 6000

continuous pressing actions.

5.4.3 When the electronic combination lock are knocked by the energy of not more than 0.5J, the

mis-operation and damage phenomena shall be avoided.

5.4.4 The electronic combination lock shall have emergency opening function. And it may have multilevel

and multi-group opening passwords.

5.4.5 The password entrance of electronic combination lock shall be prompted. When it is continuously

entered with wrong password for three times or mis-operation, the electronic combination lock shall have

time-limited locking, alarm and other functions. However, after the time-limited locking and alarm, it shall

recover the correct operation and operate normally.

5.4.6 When the supply voltage of the electronic lock changes within the range of 85%-110% of the rated

voltage, the electronic lock shall be able to work normally. When the power voltage is below the specified

alarm voltage, it shall have under-voltage alarm indications. After under-voltage alarm, the power

capacity shall still meet more than 240 times of normal opening and closing of electronic lock.

5.4.7 The electronic lock shall be equipped with external power interface or emergency opening unit.

5.4.8 For the burglary resistant safes adopting electronic lock, the key parts of electronic lock shall be

protected. When the keyboard, wire, electromechanical actuators are destroyed and attacked, they shall

be able to withstand the destruction resistant test for corresponding classes of burglary resistant safes.

5.4.9 The environmental suitability of electronic lock shall comply with the requirements of A-1/2; A-2/5;

A-3/3; A-4/1; A-6/3; and A-18/3 in GB /T15211-1994.

5.4.10 The immunity requirements of the electronic lock shall meet the test requirements specified in

GB/T 17626.2 (Grade 1), GB/T 17626.3 (Grade 1), GB/T 17626.4 (Grade 1), GB/T 17626.5 (Grade 1)

and GB/T 17626.11 (Class 40, duration of 5 cycles).

5.5 Power supply

5.5.1 The power supply's power, energy consumption, environmental adaptability and safety

requirements shall satisfy the corresponding product technical requirements.

5.5.2 When the AC 220V power supply is used as the main power supply, there shall have a standby

power (a rechargeable battery or primary battery). It works normally within the range of 85%-110% of

rated voltage of the main power supply. And there shall have an overcurrent protecti...

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 20 pages — is available in the English PDF.

Referenced standards

Normative references

GB/T 12335-1990 · GB/T 15211-1994 · GB/T 15482-1995

How to Download GB 10409-2001

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
20 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB 10409-2001

$60.00