GB 1984-2014High-voltage alternating-current circuit-breakers (English PDF)
高压交流断路器
This is a limited preview
Buy now to download the full PDF (217 pages)
Need quotation for your management?
Get a formal quotation for GB 1984-2014 in 30 minutes.
Issued by
State Administration for Market Regulation, China National Standardization Administration
Level / Type
National · Mandatory
Issue date
September 29, 2024
Implementation date
April 1, 2025
Scope
GB 1984-2014 is the English-translated version of 高压交流断路器.
GB 1984-2014 — This document specifies the operating conditions, ratings, design and structure, type testing and factory testing requirements for high voltage AC circuit breakers.
This document is applicable to three-phase power systems designed for installation indoors or outdoors and operating at voltages of 3kV and above and frequencies of 50Hz.
The invention is applicable to three-pole high voltage AC circuit breakers and also to the operating mechanisms of circuit breakers and their auxiliary equipment.
The closing and opening test methods described in this document only include direct test methods. For synthetic test methods, see GB/T 4473. NOTE The direct test method involves the use of a single source to provide voltage and current during making and breaking tests.
The inductive load switching of circuit breakers is included in GB/T 29489. This document does not apply to. ---Circuit breakers that rely on manual operation to operate the closing mechanism; --- Circuit breakers for mobile power supplies for electric traction equipment.
Such circuit breakers are included in GB/T 21413 (all parts); --- Circuit breakers for power supply and distribution systems of electrified railways. Such circuit breakers are included in GB/T 32580.1; --- Generator circuit breakers installed between the generator and the step-up transformer.
Such circuit breakers are included in GB/T 14824; --- Self-tripping circuit breakers whose tripping devices cannot be disabled during the test.
The test of automatic reclosers is specified in GB/T 25284; --- Tests not described in this document to verify performance under abnormal conditions shall be carried out according to the agreement between the manufacturer and the user.
Abnormal conditions such as those caused by a sudden loss of load on a long transmission line or cable may cause the voltage to be higher than the rated voltage of the circuit breaker.
Found what you need?
Document preview — GB 1984-2014
National Standard of the People's Republic of China
- ICS
- 29.130.10
- Classification
- K 43
- Replacing
- GB/T 1984-2014
Issued by: State Administration for Market Regulation, China National Standardization Administration
Contents
- Preface
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 3.1 General Terms and Definitions
- 3.2 Final Assembly
- 3.3 Assembly components
- 3.4 Switchgear
- 3.5 Components of a circuit breaker
- 3.6 Operational characteristics
- 3.7 Characteristic parameters
- 3.8 Fault Type
- 4 Normal and special conditions of use
- 5 Rating
- 5.1 Overview
- 5.2 Rated voltage (Ur)
- 5.3 Rated insulation level (Ud, Up and Us)
- 5.4 Rated frequency (fr)
- 5.5 Rated continuous current (Ir)
- 5.6 Rated short-time withstand current (Ik)
- 5.7 Rated peak withstand current (Ip)
- 5.8 Rated short circuit duration (tk)
- 5.9 Rated supply voltage of auxiliary and control circuits (Ua)
- 5.10 Rated frequency of auxiliary and control circuit supply voltage
- 5.11 Rated pressure of compressed gas source for controlled pressure system
- 5.12 Rated filling pressure/level for insulation and/or switching
- 5.101 Rated short-circuit breaking current (Isc)
- 5.102 Rated first open pole coefficient (kpp)
- 5.103 Rated short-circuit making current
- 5.104 Rated operating sequence
- 5.105 Rated out-of-step closing and breaking current
- 5.106 Rated capacitive current
- 6 Design and structure
- 6.1 Requirements for liquid in circuit breakers
- 6.2 Requirements for gas in circuit breakers
- 6.3 Grounding of circuit breakers
- 6.4 Auxiliary and control equipment and circuits
- 6.5 Power Operation
- 6.6 Energy storage operation
- 6.7 Operation independent of non-locking (operation independent of manpower or power)
- 6.8 Human-operated actuators
- 6.9 Operation of the trip unit
- 6.10 Pressure/Liquid Level Indicator
- 6.11 Nameplate
- 6.12 Interlocking device
- 6.13 Position indication
- 6.14 Degree of protection of enclosure
- 6.15 Creepage distance of outdoor insulators
- 6.16 Gas and vacuum sealing
- 6.17 Liquid sealing
- 6.18 Fire (flammability)
- 6.19 Electromagnetic Compatibility (EMC)
- 6.20 X-ray emission
- 6.21 Corrosion
- 6.22 Insulation and/or switching, operating filling pressure/level
- 6.101 Requirements for inter-pole synchronization during single-close and single-break operations
- 6.102 General requirements for operation
- 6.103 Pressure limits of operating fluids
- 6.104 Exhaust hole
- 6.105 Time parameter
- 6.106 Mechanical load
- 6.107 Classification of circuit breakers
- 7 Type test
- 7.1 General Principles
- 7.2 Insulation test
- 7.3 Radio Interference Voltage Test (RIV)
- 7.4 Measurement of loop resistance
- 7.5 Continuous current test
- 7.6 Short-time withstand current and peak withstand current test
- 7.7 Protection level verification
- 7.8 Sealing test
- 7.9 Electromagnetic compatibility test (EMC)
- 7.10 Additional tests on auxiliary and control circuits
- 7.11 X-ray test of vacuum interrupter
- 7.101 Mechanical and environmental tests
- 7.102 Provisions for closing and opening tests
- 7.103 General principles for making and breaking tests
- 7.104 Explanation of arcing time
- 7.105 Short-circuit test parameters
- 7.106 Short circuit test procedure
- 7.107 Terminal fault test
- 7.108 Additional short-circuit test
- 7.109 Near-field fault test
- 7.110 Out-of-step closing and opening tests
- 7.111 Capacitive current test
- 7.112 Requirements for closing and opening tests of E2 class circuit breakers with rated voltage up to and including 40.5 kV
- 7.113 Noise level test
- 8 Factory Test
- 8.1 General Principles
- 8.2 Insulation test of main circuit
- 8.3 Testing of auxiliary and control circuits
- 8.4 Measurement of main circuit resistance
- 8.5 Sealing test
- 8.6 Design inspection and appearance inspection
- 8.101 Mechanical operation test
- 9 Guidelines for selection of circuit breakers
- 9.101 General
- 9.102 Selection of rated values under operating conditions
- 9.103 Selection of ratings under fault conditions
- 9.104 Selection of electrical life
- 9.105 Selection of capacitive load switching
- 10 Documents to be provided with enquiries, tenders and orders
- 10.1 General
- 10.2 Information provided with enquiries and orders
- 10.3 Information provided with the tender documents
- 11 Rules for transportation, storage, installation, operation and maintenance
- 11.1 General
- 11.2 Conditions during transportation, storage and installation
- 11.3 Installation
- 11.4 Operation
- 11.5 Maintenance
- 11.101 Resistors and Capacitors
- 12 Safety
- 13 Impact of products on the environment
- Appendix A (Normative) Tolerances of test parameters during the test
- Appendix B (Normative) Type test records and reports
- B.1 Data and results to be recorded
- B.2 Contents of type test report
- Appendix C (Normative) Use of mechanical properties and related requirements
- Appendix D (Normative) Requirements for closing and opening test procedures for metal-enclosed circuit breakers and dead-shell circuit breakers
- D.1 General
- D.2 Reduced number of closing and breaking units for testing
- D.3 Test of single pole in one enclosure
- D.4 Test of three poles in one enclosure
- Appendix E (Normative) Requirements for circuit breakers with disconnecting resistors
- E.1 General
- E.2 Opening and closing performance verification
- E.3 Resistor connection time
- E.4 Current carrying performance
- E.5 Insulation performance
- E.6 Mechanical properties
- E.7 Requirements for the technical specifications of disconnecting resistors
- E.8 Example of recovery voltage waveform
- Appendix F (Normative) Method for determining expected TRV
- F.1 General
- F.2 Drawing the envelope
- F.3 Determination of parameters
- Appendix G (Normative) Methods for determining expected TRV waveforms
- G.1 General
- G.2 Brief description of recommended methods
- G.3 Details of the recommended approach
Foreword
This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part 1: Structure and drafting rules for standardization documents" Drafting.
This document replaces GB/T 1984-2014 "High Voltage AC Circuit Breakers". Compared with GB/T 1984-2014, except for structural adjustments and editing in addition to the changes in performance, the main technical changes are as follows.
--- Deleted the standard direction of circuit breakers with predetermined inter-pole asynchronism and circuit breakers used as bypass switches; deleted the standard direction of single-pole circuit breakers requirements that circuit breakers and bipolar circuit breakers should comply with; added "The closing and opening test methods described in this document only include direct test methods the explanation of the "Method" was added; the standard direction of circuit breakers for the power supply and distribution system of electrified railways was added (see Chapter 1, see the 2014 edition Chapter 1);
--- Added "cut-off, insulated cable, phase-separated shielded cable, DC time constant of short-circuit breaking current, lifetime sealed circuit breaker, electric Resistor switch, vacuum interrupter, opening and closing, connection time (of the trip resistor), start time of (trip or close) operation, total arcing time, terminal fault, single-phase ground fault, out-of-phase ground fault" and other terms and definitions (see Chapter 3);
--- Deleted "Indoor switchgear and control equipment, outdoor switchgear and control equipment, ground fault coefficient, self-recovery insulation, non Terms and definitions such as "self-recovering insulation, cable system, line system" (see Chapter 3 of the 2014 edition);
--- Changed the "transient recovery voltage related to rated short-circuit breaking current", "near-zone fault characteristics", "rated time parameters", "mechanical operation the number of times "according to the classification of electrical life" is located in the text (see 7.105, 7.109, 6.105, 7.101, 6.107, 2014 edition 4.102, 4.105, 4.109, 4.110, 4.111);
--- Deleted "Rated single capacitor bank closing inrush current, inductive load opening and closing", "CO-t-CO" in the rated operation sequence (see 4.107.5, 4.108, 4.104 of the 2014 edition);
--- Added "rated first open pole coefficient" (see 5.1);
--- Deleted the requirements of items 2, 3, 4, 7, and 10 in auxiliary equipment (see 5.4 of the 2014 edition);
--- Added the requirements for "manually operated drives", "time parameters", "mechanical loads" and "circuit breaker classification" (see 6.8, 6.105, 6.106 and 6.107);
--- Deleted the requirements on the number of type test products and test grouping (see 6.1.1 of the 2014 edition);
--- Added "insulation test" [see 7.1.1c)];
--- Deleted "Terminal static load test" (see Table 11 and 6.101.6 of the 2014 edition), "Shunt reactor and motor opening and closing test" (see Table 11 of the 2014 edition);
--- Added "X-ray test" and "noise level test" (see Table 5);
--- Added "repeated type test on circuit breaker with alternative operating mechanism" (see 7.1.102);
--- Added the requirements for partial discharge test of "GIS circuit breakers and circuit breakers with no power on the enclosure" (see 7.2.10);
--- Changed the status inspection requirements after mechanical or environmental tests and after closing and breaking tests (see 7.2.12.101, 7.2.12.102,
Table 8, 6.2.11, 6.101.1.4, 6.102.9 of the 2014 edition);
--- Deleted "Explanation of temperature rise test" (see 6.5.6 of the 2014 edition);
--- Deleted the corresponding requirements for circuit breakers equipped with direct overcurrent releases and self-tripping circuit breakers (see 6.6.1 of the 2014 edition), " performance of the circuit breaker during the test" (see 6.6.3 of the 2014 edition);
--- Added "No mandatory requirements for fluids used for insulation and/or opening and closing. Air or nitrogen can be used as a substitute for fluids that may cause global warming.
There is no requirement for the minimum pressure of the filled fluid" (see 7.6.2);
--- Added the use temperature requirements for products that need to undergo high and low temperature tests (see 7.101.3.1);
--- Added "Additional requirements for outdoor metal-enclosed circuit breakers" (see 7.101.3.2);
--- Added "the closing and breaking tests carried out according to level S2 cover the closing and breaking tests of level S1" (see 7.102.1);
--- Added the combined requirements for verification tests when both 50 Hz and 60 Hz tests are required (see 7.102.4.1);
--- Added "Within 1/4 power frequency cycle after breaking, the power frequency current of any pole shall be broken by the circuit breaker.
After the short circuit of the pole is broken for the first time, the reappearance of the power frequency current after more than 1/4 power frequency cycle is a breaking failure. "(See 7.102.8);
--- Changed the requirements for "circuit breaker status after test" (see 7.102.9, 6.102.9 of the 2014 edition);
--- Added inspection methods and requirements for the continuous current carrying capacity of lifetime sealed circuit breakers (see 7.102.9.4);
--- Changed the time when the power frequency recovery voltage can be reduced to Ur/3 [see 7.103.4b), 6.104.7b of the 2014 edition)];
--- Changed the provisions on arcing time (see 7.104, 6.102.10 of the 2014 edition);
--- Changed the range of the "minimum breaking time" and other relevant parameters and test procedure requirements related to T100a (see 7.104.2.2, 6.102.10.1.2 of the 2014 edition);
--- Changed the effective criterion of test method T100a, changing the I×deltat "product between 81% and 121% of the required value" to "I× deltat "the product is between 90% and 110% of the required value" (see 7.104.2.2, 7.104.3.3, 6.102.10 of the 2014 edition);
--- Added and modified Table 11, replacing Tables 15 to 19 (see Table 11, Tables 15 to 19 of the 2014 edition);
--- Added "tests covering kpp = 1.3 and kpp = 1.5 conditions" for the three-phase test (see 7.104.2.3);
--- Changed the amplitude coefficients of T10 and T30 in the expected TRV of S1 class circuit breakers (see Table 16, Table 21 of the 2014 edition);
--- Added the expected TRV of S2 class circuit breakers with three rated voltage levels of 3.6kV, 7.2kV and 12kV (see Table 17, 2014 edition
Table 22);
--- Changed the amplitude coefficients of T100 and T10 for rated voltage greater than 800kV; for test method T100, t2 is changed from "t2= 4t1" is changed to "t2=3t1"; for test method T60, t2 is changed from "t2=6t1" to "t2=4.5t1";
TRV is changed from four parameters to two parameters [see 7.105.5.1c), Table 23 of the 2014 edition];
--- Changed the arcing time during breaking operation and other contents (see 7.108.2.3, 6.108.3 of the 2014 edition);
--- Changed the wave impedance and RRRV coefficient of the near-field fault test with rated voltage greater than 800kV (see Table 25, Table 8 of the 2014 edition);
--- Changed the expected TRV standard value of the near-fault power supply circuit in Table 26 to 24kV, 40.5kV, 72.5kV, Some parameters of 1100kV (see Table 26, Table 2 to Table 5 of the 2014 edition);
--- Changed the requirements for levels C1 and C2 in the capacitive current test (see 7.111, 6.111 of the 2014 edition);
--- Added circuit breakers with rated voltage greater than 800kV, capacitive voltage coefficient kc = 1.3 (see 7.111.7);
--- Changed the step size of the capacitive current opening and closing test (see 7.111.9, 6.111.9 of the 2014 edition);
--- Increased the maximum number of tests for each test method in the capacitive current opening and closing test (see 7.111.9);
--- Deleted the test number requirements and preferred test sequence for the longest arcing time in Class C1; deleted the requirements for lines and circuits in Class C2.
The preferred test sequence for cable opening and closing tests (see 6.111.9.1 and 6.111.9.2 of the 2014 edition);
--- Changed the position of "Verification of capacitive current interruption in the presence of single-phase or two-phase ground fault" in the text (see Appendix J, 2014 Edition 6.111.9.3);
--- Deleted the relevant description of the "order" of the electrical life test (see 6.112.2 of the 2014 edition);
--- Increased the injection energy percentage of sequence 4 (see Table 30);
--- Added the calculation of equivalent gas pressure when pure SF6 gas is used for the insulation test of the main circuit of the circuit breaker using mixed gas Calculate (see 8.2);
--- Added "partial discharge measurement" (see 8.2.101);
--- Added the parameters of rated short-circuit making current at 60Hz (see 9.103.4);
--- Deleted the determination of short-circuit power factor (see Appendix D of the 2014 edition);
--- Deleted the calculation of TRV parameters under asymmetric fault conditions (T100a) (see Appendix P of the 2014 edition);
--- Added the normative appendix "Verification of capacitive current interruption in the presence of single-phase or two-phase ground fault" (see Appendix J).
This document is modified to adopt IEC 62271-100:2021 "High-voltage switchgear and controlgear Part 100: AC circuit breakers".
This document has made the following structural adjustments compared to IEC 62271-100:2021.
--- Appendix A corresponds to Appendix B of IEC 62271-100:2021;
--- Appendix B corresponds to Appendix C of IEC 62271-100:2021;
--- Appendix C corresponds to Appendix G of IEC 62271-100:2021;
--- Appendix D corresponds to Appendix H of IEC 62271-100:2021;
--- Appendix E corresponds to Appendix I of IEC 62271-100:2021;
--- Appendix F corresponds to Appendix D of IEC 62271-100:2021;
--- Appendix G corresponds to Appendix E of IEC 62271-100:2021;
--- Appendix H corresponds to Appendix F of IEC 62271-100:2021;
--- Appendix I corresponds to Appendix A of IEC 62271-100:2021.
The technical differences between this document and IEC 62271-100:2021 and their reasons are as follows.
--- According to the power grid situation in my country, the applicable frequency range is changed from "50Hz and/or 60Hz" to "50Hz", and the Part of IEC 62271-100:2021 with a rated frequency of 60 Hz (see Chapter 1);
--- Applicable voltage range. According to the power grid situation in my country, the rated voltage is changed from 1000V to 3kV, and the content related to the rated voltage is deleted.
1200kV related parameters; added "This document also applies to the operating mechanism and auxiliary equipment of the circuit breaker" and "circuit breaker the inductive load switching is included in GB/T 29489 "Circuit breakers for power supply and distribution systems of electrified railways. This type of circuit breaker includes in GB/T 32580.1" (see Chapter 1);
--- Regarding normative references, this document has made adjustments with technical differences to adapt to my country's technical conditions.
as follows.
GB/T 762 replaces IEC 60059 (see 5.101.2);
· GB 2536 replaces IEC 60296 (see 11.3.102.1.4);
GB/T 4473 replaces IEC 62271-101, GB/T 8905 replaces IEC 60480 (see 7.102.5, 7.103.4, 7.107.5.2~7.107.5.4);
· Replace IEC 60077 (all parts) with GB/T 21413 (all parts) (see Chapter 1);
GB/T 29489 replaces IEC 62271-110 (see Chapter 1 and 9.101);
GB/T 30846 replaces IEC/T R62271-302 (see 7.111.2);
· Added GB/T 28534, GB/T 32580.1, JB/T 3855, JB/T 9694 (see Chapter 1, 9.104 and 11.3.102.1.4);
--- Deleted "Closing and breaking test" and "3.8 Definition Index";
--- Added "DC time constant of short-circuit breaking current" and "fault type" (see 3.1.129, 3.8);
--- Added "5.12 Rated filling pressure/level for insulation and/or switching", which is consistent with GB/T 11022-2020 (see 5.12);
--- Deleted the relevant content of the first-pole coefficient kpp=1.2 in the whole text;
--- Deleted "near-zone fault breaking current" in Table 2 (see Table 2);
--- Changed the longitudinal horizontal force of 252kV~363kV, the longitudinal horizontal force and transverse horizontal force of 550kV~800kV in Table 3 Force, 1100kV longitudinal horizontal force and transverse horizontal force (see Table 3);
--- Deleted the term "direct connection to overhead lines" and moved its content to 6.107.3 (see 6.107.3);
--- Added verification requirements and type test cycle requirements for products transferred to other factories and produced in other places (see 7.1.1) to adapt to my country Specific circumstances;
--- Deleted the requirement that GIS circuit breakers above 363kV should be carried out in accordance with GB/T 7674, and unified the value to be taken in accordance with GB/T 11022 (see 7.2.12.103);
--- Added requirements for pneumatic and hydraulic operating mechanisms (see 7.102.6);
--- Changed the time for the power frequency current to reappear after breaking (see 7.102.8);
--- Added power factor requirements (see 7.103.2);
---Deleted the TRV parameter of the first opening coefficient kpp=1.3 for S1 and S2 class circuit breakers, and changed the First open pole coefficient (see 7.105.5.1);
--- Changed the test method, arcing time, etc. of single-phase ground fault and out-of-phase ground fault test (see 7.108.2);
--- Changed the capacitive voltage coefficient of circuit breakers with rated voltage above 800kV (see 7.111.7);
--- Added voltage requirements for combined tests (see 7.111.9.1);
--- Added sequence 4 and the injection energy percentage of sequence 4 (see Table 30);
--- Added "noise level test" (see 7.113);
--- Changed the rated short-circuit duration (see 9.103.6) to be consistent with 5.8 of GB/T 11022-2020;
--- Added calculation examples for near-field faults with "delay on the power supply side and no delay on the line side" (see Table 7.4).
1 Scope
This document specifies the operating conditions, ratings, design and structure, type testing and factory testing requirements for high voltage AC circuit breakers.
This document is applicable to three-phase power systems designed for installation indoors or outdoors and operating at voltages of 3kV and above and frequencies of 50Hz.
The invention is applicable to three-pole high voltage AC circuit breakers and also to the operating mechanisms of circuit breakers and their auxiliary equipment.
The closing and opening test methods described in this document only include direct test methods. For synthetic test methods, see GB/T 4473.
NOTE The direct test method involves the use of a single source to provide voltage and current during making and breaking tests.
The inductive load switching of circuit breakers is included in GB/T 29489.
This document does not apply to.
---Circuit breakers that rely on manual operation to operate the closing mechanism;
--- Circuit breakers for mobile power supplies for electric traction equipment. Such circuit breakers are included in GB/T 21413 (all parts);
--- Circuit breakers for power supply and distribution systems of electrified railways. Such circuit breakers are included in GB/T 32580.1;
--- Generator circuit breakers installed between the generator and the step-up transformer. Such circuit breakers are included in GB/T 14824;
--- Self-tripping circuit breakers whose tripping devices cannot be disabled during the test. The test of automatic reclosers is specified in GB/T 25284;
--- Tests not described in this document to verify performance under abnormal conditions shall be carried out according to the agreement between the manufacturer and the user.
Abnormal conditions such as those caused by a sudden loss of load on a long transmission line or cable may cause the voltage to be higher than the rated voltage of the circuit breaker.
2 Normative references
The contents of the following documents constitute essential clauses of this document through normative references in this document.
For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies to this document.
GB/T 762 Standard current levels (GB/T 762-2002, eqvIEC 60059.1999) GB/T 1985-2023 High voltage AC disconnectors and earthing switches (IEC 62271-102:2022, MOD) Note. There is no technical difference between the referenced content of GB/T 1985-2023 and the referenced content of IEC 62271-102:2022.
GB 2536 Unused mineral insulating oil for electrical fluid transformers and switches (GB 2536-2011, IEC 60296.
2003, MOD)
GB/T 2900.20-2016 Electrical terminology High-voltage switchgear and controlgear (IEC 60050-441:1984, MOD) Note. There is no technical difference between the referenced content of GB/T 2900.20-2016 and the referenced content of IEC 60050-441:1984.
GB/T 3906-2020 3.6kV~40.5kV AC Metal-enclosed Switchgear and Controlgear (IEC 62271-200.
2011,MOD)
Note. There is no technical difference between the referenced content of GB/T 3906-2020 and the referenced content of IEC 62271-100:2011.
GB/T 4109-2022 Insulating bushings for AC voltages above 1000V (IEC 60137:2017, MOD) Note. There is no technical difference between the referenced content of GB/T 4109-2022 and the referenced content of IEC 60137:2017.
GB/T 4473 Synthetic test for high voltage AC circuit breakers (GB/T 4473-2018, IEC 62271-101:2017, MOD) GB/T 7674-2020 Gas-insulated metal-enclosed switchgear with rated voltage of 72.5 kV and above (IEC 62271-203.
2011,MOD)
Note. There is no technical difference between the referenced content of GB/T 7674-2020 and the referenced content of IEC 62271-203:2011.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 217 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 1985-2023High-voltage alternating current disconnectors and earthing switches
- GB 2536Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear
- GB 2536-2011Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear
- GB/T 3906-2020Alternating-current metal-enclosed switchgear and controlgear for rated voltages above 3.6 kV and up to and including 40.5 kV
- GB/T 4109-2022Insulated bushings for alternating voltages above 1 000 V
- GB/T 4473Synthetic testing of high-voltage alternating current circuit-breakers
GB/T 762 · GB/T 762-2002 · IEC 62271 · IEC 60296 · GB/T 2900.20-2016 · IEC 60050 · IEC 60137
Cited by
- DL/T 1998-2019Technical conditions for the use of induction filter transformers
- NB/T 42107-2017High-voltage direct current circuit-breaker
- NB/T 25053-2016Technical specification of generator circuit-breaker for nuclear power plants
- NB/T 42065-2016Guide for capacitive current switching conditioning test of vacuum circuit-breaker
- GB/T 31487.3-2015Direct current de-icing devices -- Part 3: Tests
- GB/T 31989-2015Power supply safety for high voltage consumer
How to Download GB 1984-2014
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 2536-2025 — Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear
GB/T 1985-2023 — High-voltage alternating current disconnectors and earthing switches
GB/T 3906-2020 — Alternating-current metal-enclosed switchgear and controlgear for rated voltages above 3.6 kV and up to and including 40.5 kV
Secure payment via Stripe
Payments accepted
GB 1984-2014
$2,475.00