GB/T 7674-2020Gas-insulated metal-enclosed switchgear for rated voltages of 72.5kV and above (English PDF)
Also coversGBT7674-2020
Open the GB/T 7674-2020 preview as PDF
This is a limited preview
Buy now to download the full PDF
Issued by
State Administration for Market Regulation, China National Standardization Administration
Level / Type
National · Recommended
Issue date
November 19, 2020
Implementation date
June 1, 2021
Scope
GB/T 7674-2020 (Gas-insulated metal-enclosed switchgear for rated voltages of 72.5kV and above) is available as an English-translated PDF.
GB/T 7674-2020 — This standard specifies the terms and definitions, normal and special use conditions, ratings, design and structure of gas-insulated metal-enclosed switchgear: Relevant requirements for configuration, type test, factory test and selection guidelines: This standard applies to gas-insulated metal enclosures for indoor and outdoor installations with a rated voltage of 72:5kV and above and a rated frequency of 50Hz: Switchgear (hereinafter referred to as "GIS" or "switchgear"), whose insulation is obtained at least partially through insulating gas rather than at atmospheric pressure Down the air: The gas-insulated metal-enclosed switchgear covered by this standard consists of independent components that can be directly connected together, and these components can only Run in this way: According to needs, this standard completes and supplements the relevant standards applicable to the individual components of the GIS:
Document preview — GB/T 7674-2020
National Standard of the People's Republic of China
- ICS
- 29.130.10
- Classification
- K 43
- Replacing
- GB/T 7674-2008
Issued by: State Administration for Market Regulation, China National Standardization Administration
Contents
- 1 Scope1
- 2 Normative references1
- 3 Terms and definitions2
- 4 Normal and special conditions of use4
- 4:1 Overview4
- 4:2 Normal use conditions4
- 4:3 Special conditions of use4
- 5 Rating5
- 5:1 Overview5
- 5:2 Rated voltage (Ur)6
- 5:3 Rated insulation level6
- 5:4 Rated frequency (fr)7
- 5:5 Rated current and temperature rise7
- 5:6 Rated short-time withstand current (Ik)8
- 5:7 Rated peak withstand current (Ip)8
- 5:8 Rated short-circuit duration (tk)8
- 5:9 Rated power supply voltage (Ua) of closing and opening devices and auxiliary and control circuits8
- 5:10 Rated power frequency of closing and opening devices and auxiliary and control circuits8
- 5:11 Rated pressure of compressed air source for controllable pressure system8
- 5:12 Rated charging level for insulation and/or opening and closing8
- 6 Design and structure8
- 6:1 Overview8
- 6:2 Requirements for liquids in switchgear and control equipment8
- 6:3 Gas requirements in switchgear and control equipment8
- 6:4 Grounding of switchgear and control equipment9
- 6:5 Auxiliary and control equipment9
- 6:6 Power operation9
- 6:7 Energy storage operation9
- 6:8 Operations that do not rely on manpower or power (non-locking operations)9
- 6:9 Tripper operation9
- 6:10 Low pressure and high pressure blocking and monitoring devices9
- 6:11 Nameplate10
- 6:12 Interlocking device10
- 6:13 Position indication10
- 6:14 Degree of protection of the enclosure10
- 6:15 Creepage distance10
- 6:16 Gas and vacuum tightness10
- 6:17 Liquid tightness11
- 6:18 Flammability11
- 6:19 Electromagnetic compatibility (EMC)11
- 6:20 X-ray radiation11
- 6:21 Corrosion11
- 6:101 Pressure fit12
- 6:102 Internal fault12
- 6:103 Housing13
- 6:104 Partition14
- 6:105 Pressure release16
- 6:106 Noise16
- 6:107 Interface16
- 6:108 Expansion joint17
- 6:109 Observation window17
- 7 Type test18
- 7:1 General18
- 7:2 Insulation test19
- 7:3 Radio interference voltage (riv) test22
- 7:4 Loop resistance measurement22
- 7:5 Temperature rise test22
- 7:6 Short-time withstand current and peak withstand current test23
- 7:7 Verification of protection24
- 7:8 Gas tightness test and gas state measurement24
- 7:9 Electromagnetic compatibility test (EMC)24
- 7:10 Additional tests for auxiliary and control circuits24
- 7:11 X-ray test procedure for vacuum interrupter24
- 7:101 Verification of closing and breaking capacity25
- 7:102 Mechanical and environmental testing25
- 7:103 Enclosure verification test25
- 7:104 Pressure test of diaphragm26
- 7:105 Test under internal fault arc conditions27
- 7:106 Insulator test27
- 7:107 Corrosion test of ground connection27
- 7:108 Corrosion test of enclosure28
- 8 Factory test28
- 8:1 Overview28
- 8:2 Insulation test of the main circuit28
- 8:3 Test of auxiliary and control circuits29
- 8:4 Measurement of main circuit resistance29
- 8:5 Tightness test29
- 8:6 Design and visual inspection29
- 8:101 Pressure test of enclosure29
- 8:102 Mechanical operation test29
- 8:103 Test of auxiliary circuits, equipment and interlocks in control mechanisms30
- 8:104 Pressure test of diaphragm30
- 9 Guidelines for Selection of Switchgear and Control Equipment30
- 9:1 Overview30
- 9:2 Selection of ratings30
- 9:3 Continuous or transient overload caused by changes in operating conditions30
- 10 Information provided with inquiry sheet, bidding document and order30
- 10:1 Overview30
- 10:2 Inquiry and order information30
- 10:3 Information about the tender30
- 11 Transportation, storage, installation, operation and maintenance31
- 11:1 Overview31
- 11:2 Conditions of transportation, storage and installation31
- 11:3 Installation31
- 11:4 Run35
- 11:5 Maintenance35
- 12 Security35
- 13 The impact of the product on the environment35
- Appendix A (informative appendix) Structural changes of this standard compared with IEC 62271-203:201136
- Appendix B (informative appendix) Information to be given for inquiry forms, bids and orders44
- Appendix C (informative appendix) Continuity of operation50
- Appendix D (informative appendix) Calculations related to internal faults58
- Appendix E (Normative Appendix) Scope II Test procedure for insulation test of three-pole enclosed GIS59
- Appendix F (Normative Appendix) Test methods for gas-insulated metal-enclosed switchgear under internal arc fault conditions60
- Appendix G (Normative Appendix) Matters to be considered about field test technology and actual conditions63
- Reference67
Foreword
This standard was drafted in accordance with the rules given in GB/T 1:1-2009:
This standard replaces GB/T 7674-2008 "Gas insulated metal enclosed switchgear with rated voltage of 72:5kV and above", and
Compared with GB/T 7674-2008, the main technical changes are as follows:
---According to my country's environmental conditions, the relevant content of Table 101 has been modified (see 4:3, 2:2 of the:2008 edition);
---Modified the test voltage between the 126kV and 252kV fractures in Table 102 (see 5:3, 4:2 in the:2008 edition);
---The expansion joint and related technical requirements have been added (see 6:108);
---Added the observation window and related technical requirements (see 6:109);
---Modified the gas quality verification content in Chapter 10 installation (see 11:3:101:7, 10:2:101:6 in the:2008 edition);
---Added the content of appendix C operation continuity;
---Modified the content of the DC component in Appendix F Test Method under Internal Fault Arc Conditions (see F:2:2:3,:2008 edition
B:2:2:2):
This standard uses the redrafting method to modify and adopt IEC 62271-203:2011 "High-voltage switchgear and control equipment Part 203: amount
Gas-insulated metal-enclosed switchgear with constant voltage of 52kV and above":
Compared with IEC 62271-203:2011, this standard has many adjustments in structure: Appendix A lists this standard and IEC 62271-
203:2011 chapter number comparison list:
The technical differences between this standard and IEC 62271-203:2011 and the reasons are as follows:
--- Regarding normative reference documents, this standard has made adjustments with technical differences to adapt to my country's technical conditions and adjustments:
The situation is collectively reflected in Chapter 2 "Normative Reference Documents", and the specific adjustments are as follows:
* Replace IEC 60068-2-11 with GB/T 2423:17-2008 which is equivalent to adopting international standards;
* Replace IEC 62271-102:2001 with GB/T 1985-2014, which is modified to adopt international standards;
* Replace IEC 60137:2008 with GB/T 4109-2008 which is modified to adopt international standards;
* Replace IEC 60270 with GB/T 7354 which is modified to adopt international standards;
* Replace IEC 60480 with GB/T 8905 which is modified to adopt international standards;
* Replace IEC 60840 with GB/T 11017:1 modified to adopt international standards;
* Replace IEC 62067 with GB/T 22078:1 which is modified to adopt international standards;
* Replace IEC 62271-1:2007 with GB/T 11022-2011 which is modified to adopt international standards;
* Replace IEC 62271-209:2007 with GB/T 22381-2017 which is modified to adopt international standards;
* Replace IEC 62271-303 with GB/T 28537 which is modified to adopt international standards;
* Added references to GB/T 3785 (all parts), GB/T 9326 (all parts), GB/T 9789, GB/T 11023,
GB/T 12022, GB/T 13540, GB/T 16927:1, GB/T 21429, GB/T 22382-2017, GB/T 23752,
GB/T 26218 (all parts), GB/T 28819;
* Deleted IEC 60044-1:1996, IEC 60044-2:1997, IEC 60141-1, IEC 60376, IEC /T R61639:
1996, IEC 62271-100:2008, ISO 3231;
--- Delete the unquoted terms and definitions in the text, and re-describe "destructive discharge" (see Chapter 3, 3:17);
---According to the actual situation of my country's power grid, the relevant content of the rated frequency of 60Hz in the international standard has been deleted; according to my country's medium and high voltage
Classification custom, the applicable rated voltage is changed from "52kV and above" to "72:5kV and above" (see Chapter 1);
---Increase the lower limit of normal indoor and outdoor use conditions (see 4:3);
---Rated voltage, delete the rated voltage value that has nothing to do with my country's power grid, according to the voltage specified in GB/T 11022-2011
According to the actual situation of my country's power grid, relevant parameters with rated voltages of 800kV and 1100kV have been added (see 5:2);
--- The operation that does not rely on manpower or power is modified to GB/T 11022-2011 5:7 is not applicable (see 6:8);
---Added relevant technical requirements for equipment corrosion prevention (see 6:21);
---The criterion of 7:6:101 has been modified to be consistent with GB/T 11022-2011 (see 7:6:101);
--- Increased the ascent speed limit for the destructive pressure test (see 6:103:2);
---The expansion joint and related technical requirements have been added (see 6:108);
---Added the observation window and related technical requirements (see 6:109);
---Added the requirements for confirmatory test every eight years and the requirements for gas use and treatment (see 7:1:1);
--- Deleted the description of the short connecting wire on the voltage transformer in the short-time and peak withstand current test of the main circuit (see 7:6:101);
---Added the relevant requirements for the switchgear stroke---time characteristic measurement (see 7:102:3);
---Added the relevant requirements of the factory sealing test (see 8:5);
---According to the actual situation in my country, the specified value of the field test voltage in Table 7 has been modified (see 11:3:101:2:4);
---Adjust the informative appendix C of the international standard "Matters to be considered and related field test technology" to the normative appendix G:
This standard has made the following editorial changes:
---In order to be consistent with my country's technical standard system, the name of this standard is revised to "Gas Insulated Metal Seal with Rated Voltage 72:5kV and above
Closed switch equipment";
---In accordance with the requirements of GB/T 1:1-2009, the compilation of "scope" is standardized;
---The source of terms and definitions, replace IEC 60050-471 with GB/T 2900:8-2009, which is equivalent to adopting international standards:
2007; Replaced IEC 60050(441):1984 with GB/T 2900:20-2016 which was modified to adopt international standards;
---Added a note on "partition" (see 3:8);
---Added the explanation that the wet test is only carried out at the closing position (see 7:2:3);
--- Added the description that the basin insulators that have been type tested may not be tested repeatedly (see 7:106:1);
---Deleted the two informative appendices of Appendix G and Appendix H in the international standard:
This standard was proposed by China Electrical Equipment Industry Association:
This standard is under the jurisdiction of the National High Voltage Switchgear Standardization Technical Committee (SAC/TC65):
Drafting organizations of this standard: Xi'an High Voltage Apparatus Research Institute Co:, Ltd:, China Electric Power Research Institute Co:, Ltd:, State Grid Shaanxi Province
Electric Power Research Institute of Electric Power Company, Shanghai Xidian High Voltage Switchgear Co:, Ltd:, Xi'an Xidian Switch Electric Co:, Ltd:, New Northeast Electric Group
High Voltage Switchgear Co:, Ltd:, Pinggao Group Co:, Ltd:, Guangdong Power Grid Co:, Ltd: Dongguan Power Supply Bureau, Liaoning High Voltage Electrical Product Quality Inspection
Co:, Ltd:, Xiamen Huadian Switchgear Co:, Ltd:, ABB (China) Co:, Ltd:, Xiamen ABB High Voltage Switchgear Co:, Ltd:, Xi'an Xidian High
Pressure Switch Co:, Ltd:, Chuankai Electric Co:, Ltd:, Shandong Taikai High Voltage Switch Co:, Ltd:, Beijing Beikai Electric Co:, Ltd:, Special
Substation Zhongfa Shanghai High Voltage Switchgear Co:, Ltd:, TBEA Shenyang Electric Technology Research Institute Co:, Ltd:, Zhejiang Bada Electronic Instrument Co:, Ltd:
Si Shi Tong Electric Branch, Shanghai Siyuan High Voltage Switchgear Co:, Ltd:, Yihe Electric Group Co:, Ltd:, Yunnan Yunkai Electric Co:, Ltd:
Company, Huayi Electric Co:, Ltd:, Zhejiang Switch Factory Co:, Ltd:, Henan Senyuan Electric Co:, Ltd:, Haining Switch Factory Co:, Ltd:
Company, Risheng Group Co:, Ltd:
1 Scope
This standard specifies the terms and definitions, normal and special use conditions, ratings, design and structure of gas-insulated metal-enclosed switchgear:
Relevant requirements for configuration, type test, factory test and selection guidelines:
This standard applies to gas-insulated metal enclosures for indoor and outdoor installations with a rated voltage of 72:5kV and above and a rated frequency of 50Hz:
Switchgear (hereinafter referred to as "GIS" or "switchgear"), whose insulation is obtained at least partially through insulating gas rather than at atmospheric pressure
Down the air:
The gas-insulated metal-enclosed switchgear covered by this standard consists of independent components that can be directly connected together, and these components can only
Run in this way:
According to needs, this standard completes and supplements the relevant standards applicable to the individual components of the GIS:
2 Normative references
The following documents are indispensable for the application of this document: For dated reference documents, only the dated version applies to this article
Pieces: For undated references, the latest version (including all amendments) applies to this document:
GB/T 1985-2014 high voltage AC isolating switch and earthing switch (IEC 62271-102:2001 A1:2011, MOD)
GB/T 2423:17-2008 Environmental testing of electric and electronic products Part 2: Test method Test Ka: Salt spray (IEC 60068-
2-11:1981, IDT)
GB/T 3785:1 Electroacoustic Sound Level Meter Part 1: Specifications (GB/T 3785:1-2010, IEC 61672-1:2002, IDT)
GB/T 3785:2 Electroacoustic Sound Level Meter Part 2: Type Evaluation Test (GB/T 3785:2-2010, IEC 61672-2:
2003, IDT)
GB/T 4109-2008 Insulating pipe sleeves with AC voltage higher than 1000V (IEC 60137:2008, MOD)
GB/T 7354 High Voltage Test Technology Partial Discharge Measurement (GB/T 7354-2018, IEC 60270:2000, MOD)
GB/T 8905 Gas management and detection guidelines in sulphur hexafluoride electrical equipment (GB/T 8905-2012, IEC 60480:2004,
MOD)
GB/T 9326 (all parts) AC 500kV and below paper or polypropylene composite paper insulated metal sheathed oil-filled cable and accessories
[IEC 60141 (all parts)]
GB/T 9789 Metal and other inorganic coatings, sulfur dioxide corrosion test under normal condensation conditions (GB/T 9789-2008,
ISO 6988:1985, IDT)
GB/T 11017:1 Rated voltage 110kV (Um=126kV) XLPE insulated power cable and its accessories Part 1:
Test methods and requirements (GB/T 11017:1-2014, IEC 60840:2011, MOD)
GB/T 11022-2011 Common technical requirements for high-voltage switchgear and control equipment standards (IEC 62271-1:2007, MOD)
GB/T 11023 High-voltage switchgear sulfur hexafluoride gas tightness test method
GB/T 12022 Industrial sulfur hexafluoride
GB/T 13540 Seismic requirements for high-voltage switchgear and control equipment (GB/T 13540-2009, IEC 62271-2::2003,
MOD)
GB/T 16927:1 High Voltage Test Technology Part 1: General Definition and Test Requirements (GB/T 16927:1-2011,
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 1985-2014High-voltage alternating current disconnectors and earthing switches
- GB/T 4109-2008Insulated bushings for alternating voltages above 1 000 V
- GB/T 11022-2011Common specifications for high-voltage alternating-current switchgear and controlgear standards
- GB/T 11023Test method of SF6 gas tightness for high - voltage switchgear
- GB/T 12022Industrial sulphur hexafluoride
IEC 62271 · GB/T 2423 · IEC 60068 · GB/T 3785 · IEC 61672 · IEC 60137 · GB/T 7354 · GB/T 7354-2018 · IEC 60270 · GB/T 8905 · GB/T 8905-2012 · IEC 60480 · GB/T 9326 · IEC 60141 · GB/T 9789 · GB/T 9789-2008 · ISO 6988 · GB/T 11017 · IEC 60840 · GB/T 13540 · GB/T 13540-2009 · GB/T 16927
Cited by
- GB/T 42558.5-2026Seismic techniques for the electrical equipment of converter stations on plateaus - Part 5: Directives for equipment maintenance
- GB/T 11032-2020Metal-oxide surge arresters without gaps for a. c. systems
- GB/T 22071.2-2017Test guide for instrument transformers - Part 2: Inductive voltage transformers
How to Buy GB/T 7674-2020
- 1Add to cart. Click the "Buy GB/T 7674-2020" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 11017.2-2024 — Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV(Um=72.5 kV) and 110 kV (Um=126 kV) - Part 2: Power cables
GB/T 11017.3-2024 — Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 66 kV (Um=72.5 kV) and 110 kV (Um =126 kV) - Part 3: Accessories
GB/T 11023-2018 — Test method of SF6 gas tightness for high - voltage switchgear
Secure payment via Stripe
Payments accepted
GB/T 7674-2020
$950.00