GB/T 24845-2018Specification of metal–oxide surge arresters without gaps for 1000kV a.c. system (English PDF)
1000kV交流系统用无间隙金属氧化物避雷器技术规范
This is a limited preview
Buy now to download the full PDF (27 pages)
Need quotation for your management?
Get a formal quotation for GB/T 24845-2018 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
July 13, 2018
Implementation date
February 1, 2019
Scope
GB/T 24845-2018 is the English-translated version of 1000kV交流系统用无间隙金属氧化物避雷器技术规范.
GB/T 24845-2018 is the Chinese national specification for metal-oxide surge arresters without gaps used to limit overvoltages on 1000 kV AC systems. It applies both to porcelain-housed arresters and to gas-insulated metal-enclosed arresters for GIS.
The standard covers marking, standard ratings, service conditions and technical requirements, followed by type (design) tests, routine tests, acceptance tests, periodic tests and sampling tests, with a dedicated chapter on GIS arresters and rules for nameplates, packaging, transport and storage.
Its annexes deal with abnormal service conditions, the voltage distribution test method, special requirements for porcelain arresters used as post insulators, and the monitors fitted to these arresters.
Manufacturers, test laboratories and grid operators use it for design and acceptance. It was issued on 13 July 2018 and has applied since 1 February 2019.
Found what you need?
Document preview — GB/T 24845-2018
National Standard of the People's Republic of China
- ICS
- 29.240.10
- Classification
- K 44
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 logo
- 5 standard rating
- 6 operating conditions
- 7 Technical requirements
- 8 Test requirements
- 9 type test (design test)
- 10 routine tests
- 11 Acceptance test
- 12 regular test
- 13 sampling test
- 14 Gas-insulated metal-enclosed gap-free metal oxide surge arresters (GIS arresters)
- 15 Nameplates, packaging, transportation and storage
- Appendix A (Normative Appendix) Abnormal Operating Conditions
- Appendix B (Normative) Voltage Distribution Test Method
- Appendix C (Normative) Special requirements for porcelain bushing arresters for 1000kV AC systems used as post insulators
- Appendix D (Normative Appendix) Monitor for gapless metal oxide surge arresters for 1000kV AC systems
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard replaces GB /Z 24845-2009 "Technical Specification for Non-Gap Metal Oxide Arresters for 1000kV AC Systems".
Compared with GB /Z 24845-2009, the main technical changes of this standard except for editorial changes are as follows.
--- Increased the relevant parameters of the rated voltage 804kV, 780kV arrester (see 7.1);
---External insulation withstand test, residual pressure test, action load test, power frequency voltage withstand time characteristic test, short circuit current test, seismic test Tests, bending load tests, etc. have been modified according to the latest edition of the IEC and recent research results (see Chapter 9, GB /Z 24845- Chapter 10 of 2009);
--- Increased voltage equalization capacitance test, environmental test and creepage distance check (see Chapter 9);
--- Increased abnormal operating conditions of the arrester (see Appendix A);
--- Revised the calculation formula in the voltage distribution test (see Appendix B, Appendix A of GB /Z 24845-2009);
--- Added special requirements for porcelain sleeve arresters for 1000kV AC systems used as post insulators (see Appendix C);
--- Added technical requirements for monitors for gapless metal oxide surge arresters in 1000kV AC systems (see Appendix D).
1 Scope
This standard specifies the operating conditions, technical requirements, inspection rules, and tests for gapless metal oxide surge arresters for 1000kV AC systems. Inspection methods and packaging and transportation.
This standard is applicable to porcelain bushings without gap metal oxide arresters designed for limiting the overvoltage of 1000kV AC systems. It is called "arrest arrester" and gas-insulated metal-enclosed gapless metal oxide surge arrester (referred to as "GIS arrester").
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this document. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 191 storage and transportation icon
GB/T 7354 partial discharge measurement
GB/T 7674 gas insulated metal-enclosed switchgear with rated voltage of 72.5kV and above
GB/T 8905 SF6 electrical equipment in gas management and testing guidelines
GB/T 11022-2011 Common technical requirements for high voltage switchgear and control equipment standards
GB/T 11023 high voltage switchgear sulphur hexafluoride gas seal test guide
GB/T 11032-2010 AC gapless metal oxide arrester
GB/T 12022 industrial sulfur hexafluoride
GB/T 13540-1992 Seismic requirements for high voltage switchgear and control equipment
GB/T 16927.1 High Voltage Test Technique Part 1. General Definitions and Test Requirements
GB/T 26218.1 Selection and sizing of high-voltage insulators for use under filth conditions Part 1. Definitions, information and general in principle
GB/T 26218.2 Selection and sizing of high-voltage insulators for use in filth conditions - Part 2. Porcelain and glass for AC systems Glass insulator
GB 50150 Electrical installation engineering electrical equipment handover test standard
GB 50260-2013 Code for seismic design of power facilities
JB/T 10492 metal oxide arrester monitoring device
IEC 60099-4:2014 AC gap-free metal oxide surge arrester (Metal-oxidesurgearresterswithoutgapsfor Acsystems)
3 Terms and definitions
The following terms and definitions as defined in GB/T 11032-2010 and GB/T 11022-2011 apply to this document. For convenience Use, some of the terms and definitions in GB/T 11032-2010 and GB/T 11022-2011 are repeated below.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 27 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 191Graphical symbols marking for handling and storage of packages
- GB/T 7354High-voltage test techniques -- Partial discharge measurements
- GB/T 7674Gas-insulated metal-enclosed switchgear for rated voltages of 72.5kV and above
- GB/T 8905The guide for management and measuring SF6 gas in electrical equipment
- GB/T 11022-2011Common specifications for high-voltage alternating-current switchgear and controlgear standards
- GB/T 11023Test method of SF6 gas tightness for high - voltage switchgear
IEC 60099-4:2014
Similar standards
How to Download GB/T 24845-2018
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 50150-2016 — Electric equipment installation engineering-standard for hand-over test of electric equipment
GB 50260-2013 — Code for seismic design of electrical installations
GB/T 11023-2018 — Test method of SF6 gas tightness for high - voltage switchgear
Secure payment via Stripe
Payments accepted
GB/T 24845-2018
$345.00