GB/T 25307-2010High-voltage direct current by-pass switches (English PDF)
高压直流旁路开关
This is a limited preview
Buy now to download the full PDF (34 pages)
Need quotation for your management?
Get a formal quotation for GB/T 25307-2010 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
November 10, 2010
Implementation date
May 1, 2011
Scope
GB/T 25307-2010 is the English-translated version of 高压直流旁路开关.
GB/T 25307-2010 is the Chinese standard "High-voltage direct current by-pass switches". Its scope clause reads: This Standard specifies the rated values, design and structure, test of high-voltage direct current by-pass switches.
This Standard applies to the high-voltage direct current by-pass switches installed indoors or outdoors, operating at a voltage level of ± 800kV and below. This Standard is also applicable to actuators and auxiliary equipment of by-pass switches.
Its clauses include terms and definitions; normal and special conditions of use; rated values; design and structure; type test; routine tests; field test; information provided with inquiry, tender and order; safety.
It was issued by the General Administration of Quality Supervision, Inspection and Quarantine on NOVEMBER 10, 2010 and took effect on MAY 1, 2011.
Found what you need?
Document preview — GB/T 25307-2010
National Standard of the People's Republic of China
- ICS
- 29.130.10
- Classification
- K 43
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- 1 Scope4
- 2 Normative references4
- 3 Terms and definitions5
- 4 Normal and special conditions of use7
- 5 Rated values7
- 6 Design and structure11
- 7 Type test15
- 8 Routine tests24
- 9 Field test25
- 10 Information provided with inquiry, tender and order27
- 11 Transport, storage, installation, operation and maintenance rules30
- 12 Safety31
- Annex A (Informative) DC system overload current32
- Annex B (Informative) Selection guide for bypass switch operation34
Foreword
The structure of this Standard is based on GB/T 1.1.
1 Scope
This Standard specifies the rated values, design and structure, test of high-voltage direct current by-pass switches.
This Standard applies to the high-voltage direct current by-pass switches installed indoors or outdoors, operating at a voltage level of ± 800kV and below.
This Standard is also applicable to actuators and auxiliary equipment of by-pass switches.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
GB 1984-2003, High-voltage alternating-current circuit-breakers (IEC 62271-100:2001, MOD)
GB/T 2900.20-1994, Electrotechnical terminology High-voltage switchgear (neq IEC 60050 (441), IEC 60056, etc.)
GB 3906-2006, Alternating-current metal-enclosed switchgear and controlgear for rated voltages above 3.6 kV and up to and including 40.5 kV (IEC 62271-200:2003, MOD)
GB/T 5273-1985, Terminals for transformers, high-voltage apparatus and bushings (neq IEC 60518:1975)
GB/T 11022-1999, Common specifications for high-voltage switchgear and controlgear standard (eqv IEC 60694:1996)
GB/T 12022-2006, Sulphur hexafluoride for industrial use (IEC 60376:1971, IEC 60376A.1973, IEC 60376B.1974, MOD)
GB/T 13498-2007, Terminology for high-voltage direct current (HVDC) transmission (IEC 60633:1998, IDT)
3 Terms and definitions
3.15 Insulation level
[GB/T 1984-2003, definition 3.7.154]
3.16 Direct current withstand voltage
when the test is carried out under the specified conditions and the prescribed time, the DC voltage to which the bypass switch can withstand
3.17 Impulse withstand voltage
[GB/T 1984-2003, definition 3.7.156]
3.18 Short-time withstand current
[GB/T 1984-2003, definition 3.7.121]
3.19 Peak withstand current
[GB/T 1984-2003, definition 3.7.122]
3.20 DC transfer current
through the cooperation of converter bridge trigger angle, bypass switches, etc., the direct current transferred by the bypass switch to the converter bridge
3.21 Short-time DC current
under specified conditions of use and performance, the direct current to which the main circuit of by-pass switch can withstand within 30min
4 Normal and special conditions of use
Clause 2 of GB/T 11022-1999 is applicable and supplemented as follows.
For equipment installed at an altitude higher than 1000 m, the rated insulation level of the external insulation shall be corrected according to 5.1 of GB/T 20635-2006.
5 Rated values
The characteristics used to determine the rated values of the by-pass switch, its actuator and auxiliary equipment are as follows. The rated characteristics shall be given for all by-pass switches.
5.15 of GB/T 11022-1999 applies.
5.16 of GB/T 11022-1999 applies.
5.17 of GB/T 11022-1999 applies.
5.18 of GB/T 11022-1999 applies.
5.9
Rated pressure of compressed air source for insulation, operation and/or transfer of DC current 4.10 of GB/T 11022-1999 applies.
5.10 Rated DC transfer current
The rated DC transfer current of bypass switch is equal to the rated short-time DC current.
5.11 Transient recovery voltage (TRV) related to rated
DC transfer current According to 5.10, the transient recovery voltage associated with the rated DC transfer current is a reference voltage. It constitutes the limit value of the expected transient recovery voltage of the circuit to be tolerated by the by-pass switch during transfer DC operation.
5.11 of GB/T 11022-1999 applies.
5.12 Rated closing current
The by-pass switch's rated closing current is equal to the rated short-time DC current.
5.12 of GB/T 11022-1999 applies.
5.13 Rating operation sequence
The rating operation sequence of by-pass switch is related to the rating characteristics. The rating operation sequence of by-pass switch is as follow. Closing-t1-openning-t2-cloding-t1-opening, in which. t1<=0.06s, t2< 15s.
5.13 of GB/T 11022-1999 applies.
5.14 Rated time parameters
It shall specify rated values for the following time parameters.
- opening time (empty loaded);
- break time;
- closing time (empty loaded);
- opening-closing time (empty loaded);
- reclosing time (empty loaded);
- closing-opening time (empty loaded). The rated time parameters are based on.
6 Design and structure
6.1.2 of GB/T 11022-1999 applies.
6.1.3 of GB/T 11022-1999 applies.
6.2.1 of GB/T 11022-1999 applies.
6.2.3 of GB/T 11022-1999 applies.
6.10 Interlocking device
6.11 Location instructions
6.12 Protection rating of enclosure
6.13 Creepage distance
According to by-pass switch used pillar insulator antifouling performance and withstand mechanical requirements, insulators can be divided into porcelain insulator, ceramic surface coating insulator and composite insulator.
Valve room equipment recommended creepage ratio is 14 mm/kV. Indoor DC switching field recommended creepage distance is 25 mm/kV. Outdoor insulator shall be determined according to the insulator umbrella, converter station contamination conditions and the insulator material.
6.14 Gas and vacuum sealing
6.15 Liquid sealing
6.16 Flammability
6.17 Electromagnetic compatibility (EMC)
6.18 Dispersion requirements for opening operation
Opening time dispersion shall be less than 2 ms.
6.19 General requirements for operation
The bypass switch and its actuator shall be capable of completing its rated operating sequence within the entire ambient temperature range of the temperature class specified in Clause 2 of GB/T 11022-1999.
7 Type test
7.1.3 Information contained in type test report
7.2 Insulation test
7.2.1 Atmospheric conditions for test
7.2.2 Wet test program
The by-pass switch installed outdoors shall withstand the wet endurance test under the standard wet test procedure specified in GB/T 16927.1.
7.2.3 By-pass switch state in insulation test
7.2.4 Criteria for passing test
a) DC voltage withstand test If no destructive discharge occurs, the by-pass switch shall be considered to have passed the test.
During wet test, if a destructive discharge occurs on the external self-restoring insulation, the test shall be repeated under the same test conditions.
If no destructive discharges occur again, the by-pass switch shall be considered successfully passed the test. […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 34 pages — is available in the English PDF.
Referenced standards
Normative references
- GB 1984-2003High-voltage alternating-current circuit-breakers
- GB/T 2900.20-1994Electrotechnical terminology -- High-voltage switchgear and controlgear
- GB/T 5273-1985Dimensional standardisation of terminals for high-voltage apparatus
- GB/T 11022-1999Common specifications for high-voltage alternating-current switchgear and controlgear standards
- GB/T 12022-2006Industrial sulphur hexafluoride
- GB/T 13498-2007Terminology for high-voltage direct current (HVDC) transmission
GB 3906-2006
Similar standards
How to Download GB/T 25307-2010
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
GB/T 10007-2026 — Rigid cellular plastics - Determination of shear properties
Secure payment via Stripe
Payments accepted
GB/T 25307-2010
$125.00