GB/T 28565-2012High-voltage alternating-current series capacitor by-pass switches (English PDF)
高压交流串联电容器用旁路开关
This is a limited preview
Buy now to download the full PDF (92 pages)
Need quotation for your management?
Get a formal quotation for GB/T 28565-2012 in 30 minutes.
Issued by
Standardization Administration of China
Level / Type
National · Recommended
Issue date
June 29, 2012
Implementation date
November 1, 2012
Scope
GB/T 28565-2012 is the English-translated version of 高压交流串联电容器用旁路开关.
GB/T 28565-2012 — This standard specifies the high-voltage AC series capacitor bypass switch to the technical requirements, including ratings, design and construction, to test Requirements, installation, operation and maintenance rules.
This standard applies to the design, installation and operation in outdoor AC frequency 50Hz, voltage 66kV and above systems in the series capacitors Bypass switching.
This standard applies only to three-phase system bypass switch. This standard also applies to the bypass switch actuator and its auxiliary equipment.
Found what you need?
Document preview — GB/T 28565-2012
National Standard of the People's Republic of China
- ICS
- 29.130.10
- Classification
- K 43
Issued by: Standardization Administration of China
Contents
- Introduction
- 1 Overview
- 1.1 Scope
- 1.2 Normative references
- 2 Normal and special conditions of use
- 3 Terms and definitions
- 4 Rating
- 4.1 Overview
- 4.2 Rated voltage (Ur)
- 4.3 Rated insulation level
- 4.4 Rated frequency (fr)
- 4.5 Rated current (Ir) and temperature
- 4.6 Rated short time withstand current (Ik)
- 4.7 Rated peak withstand current (Ip)
- 4.8 Rated short duration (tk)
- 4.9 Closing and opening devices and auxiliary and control circuits rated supply voltage (Ua)
- 4.10 Closing and opening devices and auxiliary and control circuits Rated supply frequency
- 4.11 Insulation, operation and/or compressed air supply bypass and input with nominal pressure
- 4.101 Rated operating sequence
- 4.102 Bypass closing rated current (IBP)
- 4.103 Nominal bypass input current (IINS)
- 4.104 Rated input voltage weight (UINS)
- 4.105 Rated time parameter
- 4.106 Times mechanically operated
- 5 Design and Structure
- 5.1 Required liquid bypass switch
- 5.2 Requirements of the gas in the bypass switch
- 5.3 Grounding bypass switch
- 5.4 Auxiliary equipment
- 5.5 Operated by power
- 5.6 Charging operation
- 5.7 Does not rely on human action
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
This standard uses redrafted law revision using IEC 62271-109:2008 "high-voltage switchgear and control equipment Part 109. AC Stream series capacitor bypass switch. " this standard and IEC 62271-109:2008 main differences are as follows.
--- Scope. According to China's circumstances, to apply to the frequency of 50Hz, 66kV and above voltage AC system series capacitance Used bypass switch, remove the relevant contents of the frequency of 60Hz. Consider closing the bypass can be performed at 60Hz test loop and input current type test, it retains the above test next 60Hz relevant content.
--- Rated voltage. According to the Chinese situation, increased 1100kV relevant content.
--- Rated bypass closing current IBP. according to project needs, increased 160kA, peak.
--- Nominal bypass input current IINS. according to project needs, to be equal or greater than the rated current of the capacitor bank.
--- Joint and brake release action voltage range. According to the Chinese situation, to 65% of rated power supply voltage of closing means (DC) or between 85% to 110% (AC).
--- Shunt opening release action voltage range. According to the Chinese situation, to the opening device rated supply voltage of 85% to 110% between.
--- Plurality of release. according to project needs, the requirements of the rated voltage of 72.5kV and above-ground bypass switch provides two and a joint Opening release.
--- Release of the minimum operating supply voltage. According to the Chinese situation, to not less than 30% of the rated supply voltage.
--- Earlier requirements. According to the Chinese situation, an increase of inter-pole-year requirement. If the provisions of the inter-pole operation does not provide for the same period Special requirements, contact the biggest difference when closing moment of contact should not exceed a quarter of the nominal cycle frequency, sub-gate contact the biggest difference separating the moment should not exceed six per week rated frequency wave.
--- Factory mechanical operation test. According to China, the requirements on the full bypass switch, including 50 points - combined cycle operation.
--- Field operation test. According to China, the mechanical operation test required by the factory.
The chapters in this standard, the order of the arrangement with the IEC 62271-109:2008 "high-voltage switchgear and control equipment Part 109. AC Stream series capacitor bypass switch "basically the same.
The standard proposed by China Electrical Equipment Industrial Association.
This standard by the national high-voltage switch equipment Standardization Technical Committee (SAC/TC65) centralized.
This standard was drafted. China Electric Power Research Institute, Xi'an High Voltage Apparatus Research Institute Co., Ltd., Henan high level of electrical shares have Ltd., New Northeast Electric (Shenyang) High Voltage Switchgear Co., Ltd. Xi'an high-voltage electrical, Northeast Power Grid Corporation, North Beijing Guodian North China Power Engineering Co., Ltd., East China Electric Power Research Institute, Shaanxi Electric Power Research Institute, ABB China Ltd., Simon Sub (Hangzhou) High Voltage Switchgear Co., Ltd., Suzhou AREVA High Voltage Electric Co., Sunrise Holdings Limited.
1 Overview
1.1 Scope
This standard specifies the high-voltage AC series capacitor bypass switch to the technical requirements, including ratings, design and construction, to test Requirements, installation, operation and maintenance rules.
This standard applies to the design, installation and operation in outdoor AC frequency 50Hz, voltage 66kV and above systems in the series capacitors Bypass switching.
This standard applies only to three-phase system bypass switch.
This standard also applies to the bypass switch actuator and its auxiliary equipment.
1.2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.
GB 1984-2003 high voltage AC circuit breaker (IEC 62271-100:2001, MOD) GB/T 2900.20-1994 Electrotechnical terminology voltage switchgear (neqIEC 60050. 1984) GB/T 4473 high-voltage AC circuit breaker synthetic test (GB/T 4473-2008, IEC 62271-101:2006, MOD) GB/T 6115.1-2008 Series capacitors for power systems - Part 1. General (IEC 60143-1:2004, MOD) GB/T 6115.2-2002 Series capacitors for power systems - Part 2. Protective equipment for series capacitor banks (IEC 60143-2:1994, IDT) GB/T 11022-2011 high-voltage switchgear and control equipment standard common technical requirements (IEC 62271-1:2007, MOD) GB/T 12022 Industrial sulfur hexafluoride (GB/T 12022-2006, IEC 376, IEC 376A, IEC 376B, MOD) GB/T 16927.1 High-voltage test techniques - Part 1. General definitions and test requirements (GB/T 16927.1-2011, IEC 60060-1:2010, MOD) BIPM, IEC , IFCC, ISO , IUPAC, IUPAP, OIML.1995 Guide to the Expression of Uncertainty in Measurement
2 Normal and special service conditions
Shall comply with GB/T 11022-2011 Chapter 2.
3 Terms and Definitions
GB/T 2900.20-1994, GB 1984-2003, GB/T 6115.1-2008, GB/T 6115.2-2002 and GB/T 11022-2011 and defined the following terms and definitions apply to this document.
Generic term generalterms 3.1.101 Switching and control equipment switchgearandcontrolgear [GB 1984-2003 of 3.1.101]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 92 pages — is available in the English PDF.
Referenced standards
Normative references
- GB 1984-2003High-voltage alternating-current circuit-breakers
- GB/T 4473Synthetic testing of high-voltage alternating current circuit-breakers
- GB/T 4473-2008Synthetic testing of high-voltage alternating current circuit-breakers
- GB/T 6115.2-2002Series capacitors for power systems -- Part 2: Protective equipment for series capacitor banks
- GB/T 11022-2011Common specifications for high-voltage alternating-current switchgear and controlgear standards
- GB/T 12022Industrial sulphur hexafluoride
IEC 62271 · GB/T 2900.20-1994 · GB/T 6115.1-2008 · IEC 60143 · IEC 376 · IEC 60060
How to Download GB/T 28565-2012
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 12022-2025 — Industrial sulphur hexafluoride
GB/T 16927.1-2011 — High-voltage test techniques -- Part 1: General definitions and test requirements
GB/T 4473-2018 — Synthetic testing of high-voltage alternating current circuit-breakers
Secure payment via Stripe
Payments accepted
GB/T 28565-2012