Scope

JB/T 10840-2008 is the English-translated version of 3.6kV~40.5kV高压交流金属封闭电缆分接开关设备.

JB/T 10840-2008 is a recommended Chinese machinery industry standard for high-voltage AC metal-enclosed cable branching switchgear, and for rated voltages from 3.6 kV to 40.5 kV it specifies the product classification, the basic structure and technical requirements, the content and methods of the tests, the inspection rules, marking, packaging and transport.

It applies to metal-enclosed cable branching devices installed indoors or outdoors in three-phase AC systems of 3 kV to 35 kV nominal voltage at a rated frequency of 50 Hz, used for ring-main cable supply or for receiving and radially distributing electrical energy; other types of cable branching device may refer to it.

It also covers devices wholly or partly installed underground and liable to flooding. Its classifications are K43 and ICS 29.240.10.

Found what you need?

Document preview — JB/T 10840-2008

National Standard of the People's Republic of China

ICS
29.240.10

Issued by: Ministry of Industry and Information Technology of the People's Republic of China

Contents

  • [Preview only]
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Technical requirements
  • 4.1 General requirements
  • 4.2 Model designation
  • 6 Test methods
  • 6.1 Factory inspection
  • 6.2 Type inspection
  • 7 Inspection rules
  • 8 Marking, packaging, transportation and storage
  • 8.1 Marking
  • 8.2 Packaging

1 Foreword

JB/T 10840-2008 was issued by Ministry of Industry and Information Technology of the People's Republic of China on 1 February 2008 and has been in force since 1 July 2008.

The JB/T prefix marks a recommended standard. It is not law in itself: it becomes binding when a contract names it, when a regulation or a mandatory standard refers to it, or when a producer declares conformity with it.

The document runs to 20 pages in English translation.

2 Scope Preview

This standard is a recommended Chinese machinery industry standard for high-voltage AC metal-enclosed cable branching switchgear, and for rated voltages from 3.6 kV to 40.5 kV it specifies the product classification, the basic structure and technical requirements, the content and methods of the tests, the inspection rules, marking, packaging and transport. It applies to metal-enclosed cable branching devices installed indoors or outdoors in three-phase AC systems of 3 kV to 35 kV nominal voltage at a rated frequency of 50 Hz, used for ring-main cable supply or for receiving and radially distributing electrical energy; other types of cable branching device may refer to it. It also covers devices wholly or partly installed underground and liable to flooding. Its classifications are K43 and ICS 29.240.10.

JB/T 10840-2008 falls under ICS 29.240.10, in the field of electrical engineering.

This catalogue holds 619 other JB/T standards in that field.

In this catalogue, JB/T standards carry edition years from 1967 to 2026.

3 Normative references

GB/T 1408.1-2006 — Electrical strength of insulating materials - Test methods - Part 1: Tests at power frequencies

GB 1984-2003 — High-voltage alternating-current circuit-breakers

GB 1985-2004 — High-voltage alternating-current disconnectors and earthing switches

GB/T 2900.10-2001 — Electrotechnical terminology cable

GB/T 2900.20

GB 3804-2004 — High-voltage alternating-current switches for rated voltage above 3.6 kV and less than 40.5 kV

GB 3904-2004

GB 3906-2006

GB 4208-1993 — Degrees of protection provided by enclosure (IP code)

GB/T 8905-1996 — The guide for processing and measuring SF6 gas in power apparatus

GB/T 11022

GB/T 12706.4-2002 — Extruded insulation rated voltage of 1 kV (Um = 1. 2 kV) to 35 kV (Um = 40. 5 kV) power cables and accessories - Part 4: The rated voltage of 6 kV (Um = 7. 2 kV) to 35 kV (Um = 40. 5 kV) power Cable Test requirements on accessories

GB/T 16927-1997

GB/T 16927.1-1997 — High-voltage test techniques. Part 1: General test requirements

GB/T 17467-1998 — High-voltage/low-voltage prefabricated substations

GB/T 20138-2006 — Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code)

JB/T 8144-1995

IEC 61634-1995

IEC 62271-1-2007

IEC 62271-201-2006

4 About this standard

Issued by: Ministry of Industry and Information Technology of the People's Republic of China

English translation: about 20 pages

5 Related standards

Standards on related subjects:

GB/T 3906-2020 — Alternating-current metal-enclosed switchgear and controlgear for rated voltages above 3.6 kV and up to and including 40.5 kV

GB/T 11022-2020 — Common specifications for high-voltage alternating-current switchgear and controlgear standards

GB/T 25307-2010 — High-voltage direct current by-pass switches

JB/T 14878-2024 — Bypass switch for voltage sourced converter(VSC)valve submodules

JB/T 11531-2013 — Transmitters for Moisture Content in Sulfur Hexafluoride Gas for High Voltage Switches

JB/T 11203-2011 — Solid-insulation-embedded poles for high-voltage alternating-current vacuum switchgear

6 Classification and status

International classification (ICS): 29.240.10

Chinese Standard Classification (CCS): K 43

Prefix JB/T: recommended standard.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 20 pages — is available in the English PDF.

Referenced standards

Normative references

GB 3904-2004 · GB/T 16927-1997 · JB/T 8144-1995 · IEC 61634-1995 · IEC 62271-1-2007 · IEC 62271-201-2006

Similar standards

How to Download JB/T 10840-2008

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
20 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JB/T 10840-2008

$345.00