JB/T 10840-20083.6 kV to 40.5 kV high-voltage AC metal-enclosed cable branching switchgear (English PDF)
3.6kV~40.5kV高压交流金属封闭电缆分接开关设备
This is a limited preview
Buy now to download the full PDF (20 pages)
Need quotation for your management?
Get a formal quotation for JB/T 10840-2008 in 30 minutes.
Issued by
MIIT
Level / Type
Industry · Recommended
Issue date
February 1, 2008
Implementation date
July 1, 2008
Scope
JB/T 10840-2008 is the English-translated version of 3.6kV~40.5kV高压交流金属封闭电缆分接开关设备.
JB/T 10840-2008 is a recommended Chinese machinery industry standard for high-voltage AC metal-enclosed cable branching switchgear, and for rated voltages from 3.6 kV to 40.5 kV it specifies the product classification, the basic structure and technical requirements, the content and methods of the tests, the inspection rules, marking, packaging and transport.
It applies to metal-enclosed cable branching devices installed indoors or outdoors in three-phase AC systems of 3 kV to 35 kV nominal voltage at a rated frequency of 50 Hz, used for ring-main cable supply or for receiving and radially distributing electrical energy; other types of cable branching device may refer to it.
It also covers devices wholly or partly installed underground and liable to flooding. Its classifications are K43 and ICS 29.240.10.
Found what you need?
Document preview — JB/T 10840-2008
National Standard of the People's Republic of China
- ICS
- 29.240.10
Issued by: Ministry of Industry and Information Technology of the People's Republic of China
Contents
- [Preview only]
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Technical requirements
- 4.1 General requirements
- 4.2 Model designation
- 6 Test methods
- 6.1 Factory inspection
- 6.2 Type inspection
- 7 Inspection rules
- 8 Marking, packaging, transportation and storage
- 8.1 Marking
- 8.2 Packaging
1 Foreword
JB/T 10840-2008 was issued by Ministry of Industry and Information Technology of the People's Republic of China on 1 February 2008 and has been in force since 1 July 2008.
The JB/T prefix marks a recommended standard. It is not law in itself: it becomes binding when a contract names it, when a regulation or a mandatory standard refers to it, or when a producer declares conformity with it.
The document runs to 20 pages in English translation.
2 Scope Preview
This standard is a recommended Chinese machinery industry standard for high-voltage AC metal-enclosed cable branching switchgear, and for rated voltages from 3.6 kV to 40.5 kV it specifies the product classification, the basic structure and technical requirements, the content and methods of the tests, the inspection rules, marking, packaging and transport. It applies to metal-enclosed cable branching devices installed indoors or outdoors in three-phase AC systems of 3 kV to 35 kV nominal voltage at a rated frequency of 50 Hz, used for ring-main cable supply or for receiving and radially distributing electrical energy; other types of cable branching device may refer to it. It also covers devices wholly or partly installed underground and liable to flooding. Its classifications are K43 and ICS 29.240.10.
JB/T 10840-2008 falls under ICS 29.240.10, in the field of electrical engineering.
This catalogue holds 619 other JB/T standards in that field.
In this catalogue, JB/T standards carry edition years from 1967 to 2026.
3 Normative references
GB/T 1408.1-2006 — Electrical strength of insulating materials - Test methods - Part 1: Tests at power frequencies
GB 1984-2003 — High-voltage alternating-current circuit-breakers
GB 1985-2004 — High-voltage alternating-current disconnectors and earthing switches
GB/T 2900.10-2001 — Electrotechnical terminology cable
GB/T 2900.20
GB 3804-2004 — High-voltage alternating-current switches for rated voltage above 3.6 kV and less than 40.5 kV
GB 3904-2004
GB 3906-2006
GB 4208-1993 — Degrees of protection provided by enclosure (IP code)
GB/T 8905-1996 — The guide for processing and measuring SF6 gas in power apparatus
GB/T 11022
GB/T 12706.4-2002 — Extruded insulation rated voltage of 1 kV (Um = 1. 2 kV) to 35 kV (Um = 40. 5 kV) power cables and accessories - Part 4: The rated voltage of 6 kV (Um = 7. 2 kV) to 35 kV (Um = 40. 5 kV) power Cable Test requirements on accessories
GB/T 16927-1997
GB/T 16927.1-1997 — High-voltage test techniques. Part 1: General test requirements
GB/T 17467-1998 — High-voltage/low-voltage prefabricated substations
GB/T 20138-2006 — Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code)
JB/T 8144-1995
IEC 61634-1995
IEC 62271-1-2007
IEC 62271-201-2006
4 About this standard
Issued by: Ministry of Industry and Information Technology of the People's Republic of China
English translation: about 20 pages
5 Related standards
Standards on related subjects:
GB/T 3906-2020 — Alternating-current metal-enclosed switchgear and controlgear for rated voltages above 3.6 kV and up to and including 40.5 kV
GB/T 11022-2020 — Common specifications for high-voltage alternating-current switchgear and controlgear standards
GB/T 25307-2010 — High-voltage direct current by-pass switches
JB/T 14878-2024 — Bypass switch for voltage sourced converter(VSC)valve submodules
JB/T 11531-2013 — Transmitters for Moisture Content in Sulfur Hexafluoride Gas for High Voltage Switches
JB/T 11203-2011 — Solid-insulation-embedded poles for high-voltage alternating-current vacuum switchgear
6 Classification and status
International classification (ICS): 29.240.10
Chinese Standard Classification (CCS): K 43
Prefix JB/T: recommended standard.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 20 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 1408.1-2006Insulating materials -- Test methods for electric strength -- Part 1: Test at power frequencies
- GB 1984-2003High-voltage alternating-current circuit-breakers
- GB 1985-2004High-voltage alternating current disconnectors and earthing switches
- GB/T 2900.10-2001Electrotechnical terminology -- Electric cables
- GB/T 2900.20Electrotechnical terminology -- High-voltage switchgear and controlgear
- GB 3804-2004High-voltage alternating-current switches for rated voltage above 3.6 kV and less than 40.5 kV
GB 3904-2004 · GB/T 16927-1997 · JB/T 8144-1995 · IEC 61634-1995 · IEC 62271-1-2007 · IEC 62271-201-2006
Similar standards
How to Download JB/T 10840-2008
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 1984-2003 — High-voltage alternating-current circuit-breakers
GB 1985-2004 — High-voltage alternating-current disconnectors and earthing switches
GB 3804-2004 — High-voltage alternating-current switches for rated voltage above 3.6 kV and less than 40.5 kV
JB/T 10840-2008
$345.00