GB/T 18380.12-2008Test on electric and optical fibre cables under fire conditions -- Part 12: Test for vertical flame propagation for a single insulated wire or cable -- Procedure for 1kW pre-mixed flame (English PDF)
电缆和光缆在火焰条件下的燃烧试验 第12部分:单根绝缘电线电缆火焰垂直蔓延试验1kW预混合型火焰试验方法
GB/T 18380.12 | Evolution and historical versions
| Std ID | Title | Status |
|---|---|---|
| GB/T 18380.12-2008 | Test on electric and optical fibre cables under fire conditions -- Part 12: Test for vertical flame propagation for a single insulated wire or cable -- Procedure for 1kW pre-mixed flame | Obsolete |
GB/T 18380.12-2008 is obsolete. This page sells the obsolete edition, for projects and contracts that still cite it.
This is a limited preview
Buy now to download the full PDF (12 pages)
Need quotation for your management?
Get a formal quotation for GB/T 18380.12-2008 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine
Level / Type
National · Recommended
Issue date
June 26, 2008
Implementation date
April 1, 2009
Scope
GB/T 18380.12-2008 is the English-translated version of 电缆和光缆在火焰条件下的燃烧试验 第12部分:单根绝缘电线电缆火焰垂直蔓延试验1kW预混合型火焰试验方法.
GB/T 18380.12-2008 — This Part of GB/T 18380 specifies the test method for the vertical flame propagation of a single wire or cable under flame conditions. The test device is specified in GB/T 18380.11-2008.
NOTE 1.If necessary, the test in GB/T18380.12-2008 can be carried out simultaneously with the test in GB/T18380.13-2008. The recommended performance requirements are given in Appendix A. This Part specifies the conventional usage of 1kW pre-mixed flame.
It is not applicable to testing small-sized single wires and cables with a total cross-section area of less than 0.5 mm2, because the conductors shall be melted before the end of the test; and it is neither applicable to the small optical cables, because the optical cable shall break before the end of the test.
In these cases, the test method can refer to GB/T 18380.22- 2008. NOTE 2.The use of wires and cables that can delay the spread of flames and meet the requirements of this Standard is not sufficient to ensure that the wires and cables can prevent the spread of flames under all laying conditions.
Therefore, in some occasions with high risk of spreading, for example in long vertical runs of bunches of cable, special installation precautions shall also be taken.
It shall not be considered that the cable sample meets the performance requirements specified in this Standard, and the bundled cable shall also show similar performance (see GB/T18380.31~18380.36 series of standards).
Found what you need?
Document preview — GB/T 18380.12-2008
National Standard of the People's Republic of China
- ICS
- 29.060.20
- Classification
- K 13
Issued by: General Administration of Quality Supervision, Inspection and Quarantine
Contents
- Foreword...3
- 1 Scope...5
- 2 Normative References...5
- 3 Terms and Definitions...6
- 4 Test Devices...6
- 5 Test Procedures...6
- 6 Evaluation of the Test Result...8
- Appendix A (Informative) Recommended Performance Requirements...11
- Appendix B (Informative) Recommended Gas and Air Flowrate...12
Foreword
GB/T 18380 Test on Electric and Optical Fibre Cables under Fire Conditions can be
divided into the following 11 parts.
--- Part 11.Test for Vertical Flame Propagation for a Single Insulated Wire or Cable
– Apparatus;
--- Part 12.Test for Vertical Flame Propagation for a Single Insulated Wire or Cable
– Procedure for 1kW Pre-Mixed Flame;
--- Part 13.Test for Vertical Flame Propagation for a Single Insulated Wire or Cable-
Procedure for Determination of Flaming Droplets/Particles;
--- Part 21.Test for Vertical Flame Propagation for a Single Small Insulated Wire or
Cable - Apparatus
--- Part 22.Test for Vertical Flame Propagation for a Single Small Insulated Wire or
Cable - Procedure for Diffusion;
--- Part 31.Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or
Cables – Apparatus;
--- Part 32.Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or
Cables - Category A F/R;
--- Part 33.Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or
Cables - Category A;
--- Part 34.Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or
Cables - Category B;
--- Part 35.Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or
Cables - Category C;
--- Part 36.Test for Vertical Flame Spread of Vertically-Mounted Bunched Wires or
Cables – Category D.
This Part is Part 12 of GB/T 18380.
This Part equivalently adopts IEC 60332-1-2.2004 Test on Electric and Optical Fibre
Cables under Fire Conditions – Part 1-2.Test for Vertical Flame Propagation for a
Single Insulated Wire or Cable – Procedure for 1kW Pre-Mixed Flame (English
Version).
For the benefit of use, this Part made the following editorial modifications.
a) Delete the Foreword and Introduction of the international standard;
b) Add the Foreword for the national standard of this Part;
c) Add the appendix B;
d) Use the decimal point "." to replace the comma "," that is used for the decimal
point;
e) Use "Part 12" to replace "Part 1-2";
f) The Clause 2 quotes Chinese national standards that adopt the international
standard rather than the international standard.
The Appendixes A and B of this Part are informative.
This Part was proposed by China Electrical Equipment Industry Association.
This Part shall be under the jurisdiction of National Technical Committee for
Standardization of Wires and Cables.
Drafting organization of this Part. Shanghai Electric Cable Research Institute.
Participating drafting organizations of this Part. Jinshan Electric Wire & Cable Ltd.
Tianjin; Baosheng Science and Technology Innovation Co., Ltd.; Shanghai Nanyang
Electrical Appliance Co., Ltd.; Shanghai Yalong Industry Group Co., Ltd.; and Anhui
Hualing Cable Group Co., Ltd.
Chief drafting staffs of this Part. Gong Guoxiang, Xiao Jidong, Zheng Guojun, Tang
Chongjian, Qu Wei, Lu Bangxiu, and Hu Guangzheng.
Test on Electric and Optical Fibre Cables under Fire
Conditions - Part 12.Test for Vertical Flame
Propagation for a Single Insulated Wire or Cable -
Procedure for 1kW Pre-Mixed Flame
1 Scope
This Part of GB/T 18380 specifies the test method for the vertical flame propagation of
a single wire or cable under flame conditions. The test device is specified in GB/T
18380.11-2008.
NOTE 1.If necessary, the test in GB/T18380.12-2008 can be carried out simultaneously with
the test in GB/T18380.13-2008.
The recommended performance requirements are given in Appendix A.
This Part specifies the conventional usage of 1kW pre-mixed flame. It is not applicable
to testing small-sized single wires and cables with a total cross-section area of less
than 0.5 mm2, because the conductors shall be melted before the end of the test; and
it is neither applicable to the small optical cables, because the optical cable shall break
before the end of the test. In these cases, the test method can refer to GB/T 18380.22-
2008.
NOTE 2.The use of wires and cables that can delay the spread of flames and meet the
requirements of this Standard is not sufficient to ensure that the wires and cables can prevent
the spread of flames under all laying conditions. Therefore, in some occasions with high risk of
spreading, for example in long vertical runs of bunches of cable, special installation precautions
shall also be taken. It shall not be considered that the cable sample meets the performance
requirements specified in this Standard, and the bundled cable shall also show similar
performance (see GB/T18380.31~18380.36 series of standards).
2 Normative References
The provisions in following documents become the provisions of this Part of GB/T
18380 through reference in this Part. For dated references, the subsequent
amendments (excluding corrigendum) or revisions do not apply to this Part, however,
parties who reach an agreement based on this Part are encouraged to study if the
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 12 pages — is available in the English PDF.
Referenced standards
Cited by
- GB/T 47345-2026General specification for charging and data cables of multimedia devices
- GB/T 22577-2025Class 1E cables for nuclear power generating stations - General requirements
- GB/T 17737.10-2024Coaxial communication cables - Part 10: Sectional specification for semi-rigid cables with fluoropolymer dielectric
- GB/T 17737.11-2024Coaxial communication cables - Part 11: Sectional specification for semi-rigid cables with polyethylene(PE) dielectric
- GB/T 17737.9-2024Coaxial communication cables - Part 9: Sectional specification for flexible RF coaxial cables
- GB 43069-2023Safety requirements for mine cable
How to Download GB/T 18380.12-2008
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 18380.13-2022 — Tests on electric and optical fibre cables under fire conditions - Part 13: Test for vertical flame propagation for a single insulated wire or cable - Procedure for determination of flaming droplets/particles
GB/T 18380.11-2008 — Tests on electric and optical fibre cables under fire conditions - Part 11: Test for vertical flame propagation for a single insulated wire or cable - Apparatus
GB/T 18380.13-2008 — Test on electric and optical fibre cables under fire conditions - Part 12: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1kW pre-mixed flame
GB/T 18380.12-2008
$55.00