Valid

TB 10092-2017Code for Design of Concrete Structures of Railway Bridge and Culvert (English PDF)

Preview PDF

Also coversTB10092-2017

This is a limited preview

Buy now to download the full PDF (30 pages)

Need quotation for your management?

Get a formal quotation for TB 10092-2017 in 30 minutes.

Issued by

Ministry of Railways of the People’s Republic of China

Level / Type

National · Mandatory

Issue date

August 22, 2010

Implementation date

February 1, 2011

Scope

TB 10092-2017 (Code for Design of Concrete Structures of Railway Bridge and Culvert) is available as an English-translated PDF.

TB 10092-2017 — This Part specified the technical requirements, test methods and inspection rules of standard wall insulation cables up to AC 3 kV for cables on board rolling stock (including CRH train).

This Part applies to board rolling stocks (including CRH train); other rolling stocks can refer to this Part.

Found what you need?

Document preview — TB 10092-2017

National Standard of the People's Republic of China

ICS
29.280
Classification
S 35

Issued by: Ministry of Railways of the People’s Republic of China

Contents

  • Foreword...3
  • 1 Scope...5
  • 2 Normative references...5
  • 3 Terms and definitions...7
  • 4 Classification, code, specifications and structure of cables...7
  • 5 Technical requirements...13
  • 6 Electrical property...16
  • 7 Safety performance...18
  • 8 Inspection rules and inspection methods...19
  • 9 Delivery conditions...28
  • 10 Cable packaging, transportation and storage...28
  • Annex A (Informative) Corona lifetime test method (3kV cables)...30

Foreword

TB/T 1484 Cables on board rolling stock is divided into the following parts.

- Part 1.Standard wall insulation cables up to AC 3 kV;

- Part 2.Thin wall insulation cables;

- Part 3.30 kV Ethylene propylene rubber insulation single-phase electric power

cables;

- Part 4.Low-smoke halogen-free flame retardant cables for communications and

network.

This Part is Part 1 of TB/T 1484.

This Part is drafted according to the rules provided in GB/T 1.1-2009.

This Part, together with Part 2, replaces TB/T 1484.1-2001 Specification for railway

locomotive and vehicle cables for booking - Part 1.insulation cables up to 3 kV. The main

technical changes, compared with TB/T 1484.1-2001, are as follows.

- Revise TB/T 1484.1-2001 Specification for railway cables on board rolling stock for

booking - Part 1.insulation cables up to 3 kV into Specification for cables on board

rolling stock - Part 1.Standard wall insulation cables up to AC 3 kV and Specification

for cables on board rolling stock – Part 2.thin wall insulation cables;

- Add that the group C shall not exceed 150°C in the working temperature classification

(See 4.1.3; 4.3 in version 2001);

- Add the model naming rules and specification limit (See 4.2 and 4.3);

- Add the nominal thickness of insulation and the structure size of single insulated wire

(See 4.4.2);

- Add the water absorbability determination and acidic-alkali resistance determination

for sheath (See 5.2.5 and 5.2.6; Chapter 6 in version 2001);

- Delete continuous heat resistance (See 6.1.2 in version 2001);

- Delete tin-coating inspection item (See 9.1.2 in version 2001);

- Modify the requirements for rubbing resistance of surface markings (See 5.2.10; 6.6.2

in version 2001);

- Modify mechanical properties test indicators after oil resistant test (See 8.4.2.4; 9.2.4

in version 2001);

Specification for cables on board rolling stock –

Part 1.Standard wall insulation cables up to AC 3 kV

1 Scope

This Part specified the technical requirements, test methods and inspection rules of

standard wall insulation cables up to AC 3 kV for cables on board rolling stock (including

CRH train).

This Part applies to board rolling stocks (including CRH train); other rolling stocks can

refer to this Part.

2 Normative references

The following documents are indispensable for application of this document. For the dated

documents so quoted, only the dated versions apply to this document. For the undated

documents so quoted, the latest versions (including all modification sheets) apply to this

document.

GB 252-2000 Light diesel fuels

GB/T 2900.10-2001 Electrotechnical vocabulary - Electric cables (IEC 60050-461.1984,

IDT)

GB/T 2951.11-2008 Common test methods for insulating and sheathing materials of

electric and optical cables - Part 11.Methods for general application - Measurement of

thickness and overall dimensions - Tests for determining the mechanical properties

(IEC 60811-1-1.2001, IDT)

GB/T 2951.12-2008 Common test methods for insulating and sheathing materials of

electric and optical cables - Part 12.Methods for general application - Thermal ageing

methods (IEC 60811-1-2.1985, IDT)

GB/T 2951.13-2008 Common test methods for insulating and sheathing materials of

electric and optical cables - Part 13.Methods for general application - Measurement for

determining the density - Water absorption tests - Shrinkage test (IEC 60811-1-3.2001,

IDT)

GB/T 2951.14-2008 Common test methods for insulating and sheathing materials of

electric and optical cables - Part 14.Methods for general application - Test at low

temperature (IEC 60811-1-4.1985, IDT)

GB/T 2951.21-2008 Common test methods for insulating and sheathing materials of

electric and optical cables - Part 21.Methods specific to elastomeric compounds -

Ozone resistance, hot set and mineral oil immersion tests (IEC 60811-2-1.2001, IDT)

GB/T 3048.4-2007 Test methods for electrical properties of electric cables and wires -

Part 4.Test of DC resistance of conductors

GB/T 3048.5-2007 Test methods for electrical properties of electric cables and wires -

Part 5.Test of insulation resistance

GB/T 3048.8-2007 Test methods for electrical properties of electric cables and wires -

Part 8.AC voltage test

GB/T 3048.9-2007 Test methods for electrical properties of electric cables and wires -

Part 9.Spark test of insulated cores

GB/T 3956-2008 Conductors of insulated cables (IEC 60228.2004, IDT)

GB/T 4909.2-2009 Test methods for bare wires - Part 2.Measurement of dimensions

GB/T 4909.3-2009 Test methods for bare wires - Part 3.Tensile test

GB/T4909.11-2009 Test methods for bare wires - Part 11.Test for adherence of coating

GB/T 4910-2009 Tinned round copper wire

GB/T 6995 Markings for electric wires and cables

GB/T 12528-2008 Rail vehicle cables with rated voltages up to and including 3kV

GB/T 17650.1-1998 Test on gases evolved during combustion of materials from cables

- Part 1.Determination of the amount of halogen acid gas (idt IEC 60754-2.1991)

GB/T 17650.2-1998 Test on gases evolved during combustion of materials from cables

- Part 2.Determination of degree of acidity of gases by measuring pH and conductivity

(idt IEC 60754-2.1991)

GB/T 17651.2-1998 Measurement of smoke density of cables burning under defined

conditions - Part 2.Test procedure and requirements (idt IEC 61034-2.1997)

GB/T 18380.12-2008 Test on electric and optical fibre cables under fire conditions -

Part 12.Test for vertical flame propagation for a single insulated wire or cable -

Procedure for 1kW pre-mixed flame (IEC 60332-1-2.2004, IDT)

GB/T 18380.35-2008 Tests on electric and optical fibre cables under fire conditions -

Part 35.Test for vertical flame spread of vertically-mounted bunched wires or cables -

Category C (IEC 60332-3-24.2000, IDT)

SH/T 0139-1995 Axle oil

EN 50305.2002 Railway applications - Railway rolling stock cables having special fire

performance - Test methods

3 Terms and definitions

For the purpose of this document, the terms and definition determined in GB/T

2900.10-2001 AND the following terms and definitions shall apply.

3.1

Rated voltage

The reference voltage in cable structure design and electrical performance test,

expressed in U0, the unit is volts (V).

Note 1.U0 is the voltage effective value between one insulated conductor and ground (the metal sheath

of cables or surrounding medium of cables). In AC systems, the rated voltage of one cable shall at least

be equal to the system nominal voltage of this cable used. In DC systems, the nominal voltage of this

system shall not be larger than 1.5 times of the rated voltage of this cable.

Note 2.The working voltage of this system is allowed to exceed 10% of the nominal voltage of this

system for a long time. If the rated voltage of one cable is at least equal to the nominal voltage of this

system, the cable can work under the working voltage being higher than 10% of the rated voltage.

3.2

Standard wall

The nominal insulation thickness that complies with this Part, according to different

voltage grades, different conductor cross-sections and properties of low-smoke insulation

materials.

4 Classification, code, specifications and structure of cables

4.1 Classification

4.1.1 Grades divided according to rated voltages

250 V, 750 V, 1.500 V and 3 000 V.

4.1.2 Classification divided according to oil resistivity

I. Installed on board rolling stocks without contaminations from mineral oils and fuels

oils.

4.4.1.3 The pitch of one-time bunch-stranded conductor shall not exceed 20 times of the

outer diameter of the conductor. After multiple times of strand, the pith of outer layer shall

not be more than 20 times of the outer diameter of the conductor.

4.4.2 Insulation
4.4.2.1 The insulating layer shall be extruded on the conductor, however, it shall be easily

separated without harming the conductor or the tin coating. The insulation surface shall be

smooth with uniform color. Isolation layer is allowed to u...

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 30 pages — is available in the English PDF.

Referenced standards

Normative references

GB/T 2900.10-2001 · IEC 60050 · GB/T 2951.11-2008 · IEC 60811 · GB/T 2951.12-2008 · GB/T 2951.13-2008 · GB/T 2951.14-2008 · IEC 60228.2004 · GB/T4909.11-2009 · GB/T 6995 · IEC 60754 · IEC 61034 · IEC 60332

How to Download TB 10092-2017

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
30 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

TB 10092-2017

$125.00