GB/T 3048.9-2007Test methods for electrical properties of electric cables and wires - Part 9: Spark test of insulated cores (English PDF)
电线电缆电性能试验方法 第9部分:绝缘线芯火花试验
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 3048.9-2007 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
December 3, 2007
Implementation date
May 1, 2008
Scope
GB/T 3048.9-2007 is the English-translated version of 电线电缆电性能试验方法 第9部分:绝缘线芯火花试验.
GB/T 3048.9-2007 is the Chinese standard "Test methods for electrical properties of electric cables and wires -- Part 9: Spark test of insulated cores".
Its scope clause reads: As for the spark test of insulated cores (electric wires), this part of GB/T3048 stipulates the terms and definitions, test facilities, specimen preparation, test procedures, test result and assessment, calibration of test facilities, and test records.
This part is suitable for testing the insulating layer quality of insulated cores of rubber and plastic insulated electric cables and wires; it can be used to implement the intermediate test and routine test of electric cables and wires.
It cannot be used to test the insulation products of conducting cores made of non-conducting materials. This part includes power frequency spark test and direct current spark test.
That is to say, the test is implemented with power frequency spark machine and direct current spark machine. This part shall be used together with GB/T3048.1. Its clauses include terms and definitions; test facilities; specimen preparation; test procedures; test result and assessment; calibration of test facilities; test records.
It was issued by the General Administration of Quality Supervision, Inspection and Quarantine on DECEMBER 03, 2007 and took effect on MAY 01, 2008.
Found what you need?
Document preview — GB/T 3048.9-2007
National Standard of the People's Republic of China
- ICS
- 29.060
- Classification
- K 13
- Replacing
- GB/T 3048.9-1994
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- 1 Scope6
- 2 Normative references6
- 3 Terms and definitions6
- 4 Test Facilities7
- 5 Specimen Preparation10
- 6 Test Procedures11
- 7 Test Result and Assessment11
- 8 Calibration of Test Facilities11
- 9 Test Records12
Foreword
GB/T 3084 Test methods for electrical properties of electric cables and wires is divided into 14 parts as follows [Translator note. Parts 6 & 15 do not exist].
- Part 1: General;
- Part 2: Test of electrical resistivity of metallic materials;
- Part 3: Test of volume resistivity of semi conducting rubbers and plastics;
- Part 4: Test of DC resistance of conductors;
- Part 5: Test of insulation resistance;
- Part 7: Tracking resistance test;
- Part 8: AC voltage test;
- Part 9: Spark test of insulated cores;
- Part 10: Spark test of extruded protective sheaths;
- Part 11: Test for dielectric dissipation factor;
- Part 12: Partial discharge test;
- Part 13: Impulse voltage test;
- Part 14: DC voltage test;
- Part 16: Surface resistance test.
This part is part 9 of GB/T 3084.
This part replaces GB/T 3048.9-1994 Test methods for electrical properties of electric cables and wires - Part 9: Spark test of insulated cores and GB/T 3048.15-1992 Electric cables and wires - D.C. spark test method for insulated cores. This revision makes modifications based on GB/T 1.1-2000 Directives for Standardization - Part 1: Rules for the Structure and Drafting of Standards.
The main changes in this part, compared with GB/T 3048.4-1994 and GB/T 3048.15-1992, are as follows.
- The title of the standard in Chinese has been changed to "Test methods for electrical properties of electric cables and wires - Part 9: Spark test of insulated cores";
- The title of the standard in English has been changed to "Test methods for electrical properties of electric cables and wires - Part 9: Spark test of insulated cores";
- The general structure and layout of this part have been changed according to GB/T 1.1-2000.
1) Clause 1 is "scope" (Clause 1 in GB/T 3048.9-1994 and GB/T 3048.15-1992 edition; Clause 1 in this edition);
2) Clause 2 is "normative references" (Clause 2 in GB/T 3048.9-1994 edition; none in GB/T 3048.15-1992 edition, Clause 2 in this edition);
3) Clause 3 is "terms and definitions" (none in GB/T 3048.9-1994 and GB/T 3048.15-1992 edition, Clause 3 in this edition)
4) Clause 3 is "testing equipment" (Clause 3 in GB/T 3048.9-1994 edition; Clause 3 in GB/T 3048.15-1992 edition, Clause 4 in this edition);
5) Clause 5 is "sample preparation" (none in GB/T 3048.9-1994 edition and GB/T 3048.15-1992 edition; Clause 5 in this edition);
6) Clause 6 is "test procedure" (Clause 4 and 5 in GB/T 3048.9-1994 edition;
Clause 3 and 4 in GB/T 3048.15-1992 edition; Clause 6 in this edition);
7) Clause 7 is "test result and calculation" (Clause 6 in GB/T 3048.9-1994 edition;
Clause 5 in GB/T 3048.15-1992 edition and Clause 7 in this edition);
8) Clause 8 is "calibration of test equipment" (Clause 7 in GB/T 3048.9-1994 edition non in GB/T 3048.15-1992 edition).
9) Clause 9 is "test record" (none in GB/T 3048.9-1994 edition and GB/T 3048.15-1992, clause 9 in this edition);
- Some content, part including requirements, is deleted from Clause 1 "scope" (Clause 1 in GB/T 3048.15-1992; Clause 1 in this edition);
- Relevant standards are supplemented in Clause 2 "normative references" (Clause 2 GB/T 3048.9-1994; none in GB/T 3048.15-1992; Clause 2 in this edition);
- Clause 3 "terms and definitions" is added (none in GB/T 3048.9-1994 and GB/T 3048.15-1992; Clause 3 in this edition);
- The regulations on DC high voltage power supply ripples in Clause 4 "testing equipment" are changed (2.1 in GB/T 3048.15-1992, 4.4.2 in this edition);
- The test voltage is changed from the specified value to the recommended value in Clause 6 "test procedure" (Clause 4 in GB/T 3048.9-1994 and Clause 3 in GB/T Test methods for electrical properties of electric cables and wires - Part 9: Spark test of insulated cores
1 Scope
As for the spark test of insulated cores (electric wires), this part of GB/T3048 stipulates the terms and definitions, test facilities, specimen preparation, test procedures, test result and assessment, calibration of test facilities, and test records.
This part is suitable for testing the insulating layer quality of insulated cores of rubber and plastic insulated electric cables and wires; it can be used to implement the intermediate test and routine test of electric cables and wires. It cannot be used to test the insulation products of conducting cores made of non-conducting materials.
This part includes power frequency spark test and direct current spark test. That is to say, the test is implemented with power frequency spark machine and direct current spark machine. This part shall be used together with GB/T3048.1.
2 Normative references
The articles contained in the following documents have become the articles of this part when they are quoted in this part of GB/T 3048. For the dated documents so quoted, all subsequent modifications (including all corrections) or revisions made thereafter do not apply to this standard. However, the parties who reach an agreement according to this standard are encouraged to study whether the latest versions of these documents may be used. For the undated documents so quoted, the latest versions (including all modification sheets) apply to this document.
GB/T 2900.10-2001 Electrotechnical vocabulary - Electric cables (idt IEC 60050 (461).1984)
GB/T 3048.1 Test methods for electrical properties of electric cables and wires - Part 1: General
JB/T 4278.10 Verification procedure for test equipment of rubber plastic wire and cable - Part 10: Spark tester
3 Terms and definitions
a) The diameter of the bead shall be 2 to 5mm; the space between the two neighboring beads in one bead chain shall not be more than 2.5mm;
b) The loop is made of metal wire with the diameter of more than 0.8mm; and the outer diameter of the loop shall not be more than 5mm. If you choose oval or other forms, the vertical axis shall not be more than 5mm. For every 100mm long loop chain, the number of loops shall not be less than 20;
c) The beads or loops of the chain shall be distributed uniformly. The surface shall be smooth; and any rags which may scratch the tested insulated cores shall not exist on the surface. Moreover, every bead or loop shall be flexible and compassable. Bead chain or loop chain shall be cross-banding.
4 Test Facilities
4.4 Guard electrode
Both ends of the testing electrode shall have grounded guard electrodes. The width of guard electrodes shall not be less than the width of testing electrode; the length of guard electrodes (axial direction) shall not be less than 15mm. The bead chain or loop chain being used shall comply with the testing electrode. The space between guard electrode and testing electrode shall ensure that, under the normal highest test voltage, the specimen insulator surface flashover can be avoided.
4.5 Safety protection interlocking device
When the testing electrode box is opened, the device can automatically cut off the high voltage power supply.
4.6 Breakdown indicator
Breakdown indicator is composed of a digital display counter and a sounding alarm; it can record every breakdown and give an alarm. The breakdown indicator shall keep the indicated number until the next breakdown is recorded or the indicator is reset manually.
The alarm time of the sounding alarm can keep several seconds; and it can trigger the breaker to cut off high voltage power supply and drive system power supply. When necessary, it can intercept the triggering signal.
4.7 Sensitivity
4.7.1 Sensitivity test
The sensitivity is tested with artificial breakdown device.
In the artificial breakdown device test, the spark gap is formed by a metal plate and a metal pinpoint that is relatively rotated. In every second, the space between the metal plate and pinpoint can reach 0.25±0.05mm once. In power frequency spark test, the time of duration is 0.025s; in direct current spark test, the time of duration is 0.005s. As for the polarity of the pinpoint and metal plate, the pinpoint is negative electrode and the metal plate is positive electrode. […]
4.7.2 Lowest sensitivity test
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
Cited by
- GB/T 29631-2025Flexible torsion-resistant cables of rated voltages up to and including 1.8/3 kV for wind power generation
- NB/T 11128-2023Rubber sheathed flexible cable for frequency converter equipment of coal mine
- NB/T 11129-2023Control cable for coal mine
- JB/T 13106-2017Power cable with silicone rubber insulation for rated voltages of 0.6/1 kV
- JB/T 13107-2017Silicone rubber insulated and sheathed flat cable of rated voltage up to and including 0.6/1 kV
- JB/T 13108-2017Silicone rubber insulated control cables of rated voltages up to and including 450/750 V
Similar standards
Editions of GB/T 3048.9
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 3048.9-2007 | Test methods for electrical properties of electric cables and wires - Part 9: Spark test of insulated cores | current edition | Current |
| GB/T 3048.9-1994 | Test methods for electrical properties of electric cables and wires - Part 9: Spark test of insulated cores | previous edition | Superseded |
This page sells the current edition, GB/T 3048.9-2007. Earlier editions are listed for reference only.
How to Download GB/T 3048.9-2007
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 3048.1-2007 — Test methods for electrical properties of electric cables and wires - Part 1: General
GB/T 3048.10-2007 — Test methods for electrical properties of electric cables and wires - Part 10: Spark test of extruded protective sheaths
GB/T 3048.11-2025 — Test methods for electrical properties of electric cables and wires — Part 11: Test for dielectric dissipation factor
Secure payment via Stripe
Payments accepted
GB/T 3048.9-2007
$115.00