Valid

JG/T 442-2014Irradiation crosslinking low-smoke halogen-free flame retardant power cables with double-layer extrusion insulation of rated voltage 0.6/1 kV (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (36 pages)

Need quotation for your management?

Get a formal quotation for JG/T 442-2014 in 30 minutes.

Issued by

Ministry of Housing and Urban-Rural Development of the People's Republic of China

Level / Type

National · Recommended

Issue date

September 11, 2014

Implementation date

February 1, 2015

Scope

JG/T 442-2014 (Irradiation crosslinking low-smoke halogen-free flame retardant power cables with double-layer extrusion insulation of rated voltage 0.6/1 kV) is available as an English-translated PDF.

JG/T 442-2014 — This standard specifies the terms and conditions of rated voltage 0.6/1kV double co-extruded insulation cross-linked halogen-free low smoke flame retardant, fire-resistant power cable Meaning, Classification and Marking, General Provisions, Requirements, Test Methods, Inspection, Marking, Packaging, Transport and Storage.

This standard applies to industrial and civil buildings rated voltage 0.6/1kV double co-extruded insulation radiation cross-linked halogen-free low smoke flame retardant, fire-resistant electricity cable.

Found what you need?

Document preview — JG/T 442-2014

National Standard of the People's Republic of China

ICS
29.060.20
Classification
K 13

Issued by: Ministry of Housing and Urban-Rural Development of the People's Republic of China

Contents

  • Preface
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Classification and marking
  • 5 General Provisions
  • 6 Requests
  • 7 Test methods
  • 8 Test
  • 9 Logo, packaging, transportation and storage
  • Appendix A (Normative) Insulation material mechanical and electrical properties
  • Appendix B (Normative) Aluminum alloy armored with interlocking technical requirements
  • Appendix C (Normative) Sheath material mechanical properties and electrical properties
  • Appendix D (Informative) Calculation of circuit carrying capacity and conductor cross-sectional area of
  • Appendix E (Informative) Cable Reference Current
  • Appendix F (Informative) Creep test method
  • Annex G (Normative) Interlocking armor layer tightness test
  • Appendix H (Normative) Interlocking armor tensile and elongation test
  • Appendix I (Normative) Crush test at room temperature
  • Appendix J (Normative) Impact test at room temperature
  • Appendix K (Informative) Carrying capacity test

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009.

This standard proposed by the Ministry of Housing and Urban Standard and Design Institute.

This standard by the Ministry of Housing and Urban Construction Electric Standardization Technical Committee.

1 Scope

This standard specifies the terms and conditions of rated voltage 0.6/1kV double co-extruded insulation cross-linked halogen-free low smoke flame retardant, fire-resistant power cable Meaning, Classification and Marking, General Provisions, Requirements, Test Methods, Inspection, Marking, Packaging, Transport and Storage.

This standard applies to industrial and civil buildings rated voltage 0.6/1kV double co-extruded insulation radiation cross-linked halogen-free low smoke flame retardant, fire-resistant electricity cable.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version applies to this article Pieces. For undated references, the latest edition (including all amendments) applies to this document.

GB/T 1408.1-2006 Insulating material electrical strength test methods - Part 1. Test at power frequency (IEC 60243-1.:1998, IDT) GB/T 1410-2006 Test methods for volume resistivity and surface resistivity of solid insulating materials (IEC 60093. 1980, IDT) GB/T 2406.2-2009 Plastics - Determination of combustion behavior by oxygen index method - Part 2. Room temperature test (ISO 4589-2.:1996, IDT) GB/T 2900.10 Electrotechnical terminology cables (IEC 60050-461.:2008, IDT) GB/T 2951.11-2008 Common test methods for insulating and sheathing materials of electric cables and cables - Part 11. Common test methods Method --- thickness and shape measurement --- mechanical properties test (IEC 60811-1-1.:2001, IDT) GB/T 2951.12-2008 Common test methods for insulating and sheathing materials of electric cables and cables - Part 12. Common test methods Method --- thermal aging test method (IEC 60811-1-2. 1985, IDT) GB/T 2951.13-2008 Common test methods for insulating and sheathing materials of electric cables and cables - Part 13. General test methods Method --- Determination of density --- Water absorption test --- Shrinkage test (IEC 60811-1-3.:2001, IDT) GB/T 2951.14-2008 Common test methods for insulating and sheathing materials of electric cables and cables - Part 14. Common test methods Method --- low temperature test (IEC 60811-1-4. 1985, IDT) GB/T 2951.21-2008 Common test methods for insulating and sheathing materials of electric cables and cables - Part 21. Elastomer mixtures Test methods --- ozone-resistant test --- thermal elongation test --- immersion mineral oil test (IEC 60811-2-1.:2001, IDT) GB/T 2951.31-2008 Common test methods for insulating and sheathing materials of electric cables and cables - Part 31. Polyvinyl chloride compounds Specific test methods --- High temperature pressure test --- Cracking resistance test (IEC 60811-3-1. 1985, IDT) GB/T 3048.4-2007 wire and cable electrical performance test methods - Part 4. Conductors DC resistance test GB/T 3048.8 wire and cable electrical performance test methods Part 8. AC voltage test GB/T 3048.9 wire and cable electrical performance test methods - Part 9. insulated wire spark test GB/T 3048.10 wire and cable electrical performance test methods - Part 10. Extrusion sheath spark test GB/T 3082 armored cable with hot-dip galvanized or hot dip galvanized -5% aluminum - mixed rare earth alloy coating low-carbon steel wire GB/T 3956-2008 Cable conductor (IEC 60228.:2004, IDT) Bare wires - Test methods - Part 2. Measurement of dimensions GB/T 4909.2-2009 GB/T 4909.3 Bare wire test methods - Part 3. Rally test GB/T 4909.5 Bare wire test methods - Part 5. Bending test --- repeated bending GB/T 5013.2-2008 Rubber insulated cables of rated voltages up to and including 450/750 V - Part 2. Test methods (IEC

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 36 pages — is available in the English PDF.

Referenced standards

Normative references

IEC 60243 · IEC 60093 · ISO 4589 · GB/T 2900.10 · IEC 60050 · IEC 60811 · IEC 60228 · GB/T 5013.2-2008

How to Download JG/T 442-2014

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
36 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

JG/T 442-2014

$1,104.00