Scope
GB/T 5013.2-2008 is the English-translated version of 额定电压450/750V及以下橡皮绝缘电缆 第2部分:试验方法.
GB/T 5013.2-2008 — This section GB/T 5013 gives the test all parts of GB/T 5013 provisions and not included in GB/T 2951 in method.
Found what you need?
Document preview — GB/T 5013.2-2008
National Standard of the People's Republic of China
- ICS
- 29.060.20
- Classification
- K 13
- Replacing
- GB 5013.2-1997
Issued by: Standardization Administration of China
Contents
- Foreword
- 1 Overview
- 1.1 Scope
- 1.2 Normative references
- 1.3 Test by frequency classification
- 1.4 Sampling
- 1.5 Pretreatment
- 1.6 Test temperature
Foreword
GB/T 5013 "rated voltage 450/750V and below rubber insulated cable" is divided into eight sections.
--- Part 1. General requirements;
--- Part 2. Test methods;
--- Part 3. Heat resistant silicone rubber insulated cables;
--- Part 4. Cords and flexible cables;
--- Part 5. Lift cables;
--- Part 6. Arc welding cables;
--- Part 7. Heat resistant ethylene - vinyl acetate rubber insulated cables;
--- Part 8. Cords.
This section GB/T 5013 Part 2. This section identical with IEC 60245-2:1998 "rated voltage 450/750V and with Under Rubber insulated cables - Part 2. Test methods "(in English).
For ease of use, GB/T 5013 made this part of the following editorial changes.
"." --- With a decimal point instead of a comma as the decimal point, "";
--- Delete international standards foreword.
This part of the IEC in its original title of Chapter 4 editorial errors have been corrected to "IE4 type insulating rubber mixture in an air oven Air missile and mechanical tests "after aging.
This section from the implementation date instead of GB 5013.2-1997.
This section of the main changes compared to GB 5013.2-1997 are as follows.
--- 3.1 "Flexing Test" rearrange the content, and the weight of the hammer, pulley diameter and the applied current parameters made amendments and supplements;
--- Increase of 3.5 "three Flexing Test" and 3.6 "twist test";
--- Chapter 4, respectively, with "IE4", "air" and "8.2" replace the original "IE1", "oxygen" and "8.3." this part is proposed by the China Electrical Equipment Industrial Association.
This part of the National Standardization Technical Committee of wire and cable.
This part of the unit responsible for drafting. Shanghai Electric Cable Research Institute.
1 Overview
1.1 Scope
This section GB/T 5013 gives the test all parts of GB/T 5013 provisions and not included in GB/T 2951 in method.
1.2 Normative references
The following documents contain provisions which, through GB/T reference in this 5013 constitute provisions of this section. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section.
GB/T 131 Geometrical product specifications (GPS) technology products in the surface structure of the file notation (GB/T 131-2006, ISO 1302:2002, IDT) GB/T 2951.1-1997 cable insulation and sheathing materials test methods - Part 1. General Test Methods 1. Thick Degree and dimensions measuring --- mechanical tests (idt IEC 60811-1-1:1993) GB/T 2951.2-1997 cable insulation and sheathing materials test methods - Part 1. General test methods - Part 2. Hot Aging methods (idt IEC 60811-1-2. 1985) GB/T 5013.1-2008 rated voltage of 450/750V and below rubber insulated cables - Part 1. General requirements (IEC 60245-1:2003, IDT) GB/T 5013.3 rated voltage of 450/750V and below rubber insulated cables - Part 3. Heat resistant silicone rubber insulated cables (GB/T 5013.3-2008, IEC 60245-3:1994, IDT) GB/T 5013.4-2008 rated voltage of 450/750V and below rubber insulated cables Part 4. Cords and flexible cables (IEC 60245-4:2004, IDT) GB/T 5013.8-2006 rated voltage of 450/750V and below rubber insulated cables Part 8. Cords (IEC 60245-8:1998, IDT) GB/T 18380.1 cables under fire conditions test - Part 1. single insulated wire or cable vertical burning test the method (GB/T 18380.1-2001, IEC 60332-1:1993, IDT)
1.3 Test by frequency classification
According to GB/T 5013.1-2008 defined in 2.2, the test is defined as type tests (symbol T) and/or sampling tests (symbol S).
Symbol T and S for use in product standards (GB/T 5013.3, GB/T 5013.4, etc.) related to the table.
1.4 Sampling
If the insulation or sheath using embossed Braille signs, sampling should include this flag.
Unless otherwise specified, for multi-core cables, in addition to the tests specified in 1.9, it should take no more than three core samples (if separations take any different Color) were tested.
1.5 Pretreatment
In order to carry out all the tests should be kept at least 16h after curing insulation or jacket.
1.6 Test temperature
Unless otherwise specified, the tests should be carried out at ambient temperature.
GB/T 5013.2-2008/IEC 60245-2:1998
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 7 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 131Geometrical Product Specifications (GPS) -- Indication of Surface texture in technical Product documentation
- GB/T 131-2006Geometrical Product Specifications (GPS) -- Indication of Surface texture in technical Product documentation
- GB/T 5013.1-2008Rubber insulated cables of rated voltages up to and including 450/750 V -- Part 1: General requirements
- GB/T 5013.3Rubber insulated cables of rated voltages up to and including 450/750 V -- Part 3: Heat resistant silicone insulated cables
- GB/T 5013.3-2008Rubber insulated cables of rated voltages up to and including 450/750 V -- Part 3: Heat resistant silicone insulated cables
- GB/T 5013.4-2008Rubber insulated cables of rated voltages up to and including 450/750V -- Part 4: Cords and flexible cables
ISO 1302 · GB/T 2951.1-1997 · IEC 60811 · GB/T 2951.2-1997 · IEC 60245 · GB/T 18380.1 · GB/T 18380.1-2001 · IEC 60332
Cited by
- GB/T 15092.2-2023Switches for appliances - Part 2-1: Particular requirements for cord switches
- GB/T 38428.1-2019Direct current (DC) plugs and socket-outlets for information and communication technology (ICT) equipment installed in data centres and telecom central offices -- Part 1: General requirements
- CJ/T 518-2017Submersible axial-flow pump
- CJ/T 472-2015Submersible sewage pump
- JB/T 12023-2014250 A~630 A Plugs, Socket-outlets and Couplers for Industrial Purposes
- JG/T 442-2014Irradiation crosslinking low-smoke halogen-free flame retardant power cables with double-layer extrusion insulation of rated voltage 0.6/1 kV
How to Download GB/T 5013.2-2008
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 131-2006 — Geometrical Product Specifications (GPS) -- Indication of Surface texture in technical Product documentation
GB/T 1310.2-2009 — Varnished fabrics for electrical purposes -- Part 2: Methods of test
GB/T 1311-2024 — Test methods for direct current machines
Secure payment via Stripe
Payments accepted
GB/T 5013.2-2008
$95.00