Scope

GB/T 5013.5-2008 is the English-translated version of 额定电压450/750V及以下橡皮绝缘电缆 第5部分:电梯电缆.

GB/T 5013.5-2008 — GB/T 5013 This section gives the rated voltage of 300/500V rubber insulated technical requirements for elevator cables. Each cable shall comply with the requirements and the specific requirements of this part of GB/T 5013.1 regulations.

Found what you need?

Document preview — GB/T 5013.5-2008

National Standard of the People's Republic of China

ICS
29.060.20
Classification
K 13
Replacing
GB 5013.5-1997

Issued by: Standardization Administration of China

Contents

  • Foreword
  • 1 Overview
  • 1.1 Scope
  • 1.2 Normative references
  • 2.1 Model
  • 2.2 Rated voltage
  • 2.3 Structure

Foreword

GB/T 5013 "rated voltage 450/750V and below rubber insulated cable" is divided into eight sections.

--- Part 1. General requirements;

--- Part 2. Test methods;

--- Part 3. Heat resistant silicone rubber insulated cables;

--- Part 4. Cords and flexible cables;

--- Part 5. Lift cables;

--- Part 6. Arc welding cables;

--- Part 7. Heat resistant ethylene - vinyl acetate rubber insulated cables;

--- Part 8. Cords.

This section GB/T 5013 Part 5. This section identical with IEC 60245-5:1994 "rated voltage 450/750V and with Under rubber insulated cables - Part 5. Lift cables "(in English) and its amendments Amendment1.2003 (English version).

For ease of use, GB/T 5013 made this part of the following editorial changes.

--- As an alternative to the decimal by decimal comma ",". ",";

--- Delete international standards foreword.

This section from the date of implementation of alternative GB/T 5013.5-1997.

This section of the main changes compared to GB 5013.5-1997 are as follows.

--- 2.3.2 "isolation layer" removed "the relevant requirements see GB 5013.1-1997 5.1.3";

--- Insulating material "IE4" replacement "IE1";

--- Table 2 3.3 pilot project to "air missile after aging tensile test";

--- Table 2 increased 3.5 Test Project "Ozone Test." this part is proposed by the China Electrical Equipment Industrial Association.

This part of the National Standardization Technical Committee of wire and cable.

This part of the unit responsible for drafting. Shanghai Electric Cable Research Institute.

Participated in the drafting of this section. Hualing Cable Group Co., Ltd., Fujian Nanping Sun Cable Co., Ltd., Guangdong Huasheng Electric is Industrial Co., Ltd., Jiangsu Cable Group, Shanghai Nanyang Electric Wire Co., Ltd., Wuxi Jiangnan Cable Co., Ltd.

1 Overview

1.1 Scope

GB/T 5013 This section gives the rated voltage of 300/500V rubber insulated technical requirements for elevator cables.

Each cable shall comply with the requirements and the specific requirements of this part of GB/T 5013.1 regulations.

1.2 Normative references

The following documents contain provisions which, through GB/T reference in this 5013 constitute provisions of this section. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section.

GB/T 2951.1-1997 cable insulation and sheathing materials test methods - Part 1. General Test Methods 1. Thick Degree and dimensions measuring --- mechanical tests (idt IEC 60811-1-1:1993) GB/T 2951.2-1997 cable insulation and sheathing materials test methods - Part 1. General test methods - Part 2. Hot Aging methods (idt IEC 60811-1-2. 1985) GB/T 2951.5-1997 cable insulation and sheathing materials test methods - Part 2. elastomeric compounds specific test side Act 1. Ozone resistance test --- --- Hot set test - Mineral oil immersion test (idt IEC 60811-2-1. 1986) GB/T 3956 cable conductor (GB/T 3956-1997, idt IEC 60228. 1978) GB/T 5013.1-2008 rated voltage of 450/750V and below rubber insulated cables - Part 1. General requirements (IEC 60245-1:2003, IDT) GB/T 5013.2-2008 rated voltage of 450/750V and below rubber insulated cables - Part 2. Test methods (IEC 60245-2:1998, IDT) Woven, high-strength rubber, neoprene or other equivalent synthetic elastomer 2 general-purpose rubber elevator cable 1)

1) high-speed or high-rise building with an elevator cable elevator cable standards are under consideration.

2) does not exclude other structure containing a cable core number or more number of cores.

2.1 Model

Braided elevator cable. 60245IEC 70 (YTB);

High strength rubber elevator cable. 60245IEC 74 (YT);

Neoprene or other equivalent synthetic elastomer insulated lift cables. 60245IEC 75 (YTF).

2.2 Rated voltage

300/500V.

2.3 Structure

2.3.1 Conductor

Contacts. 6,9,12,18,24 or 30 core 2).

Conductor shall meet the requirements of GB/T 3956 in the fifth conductor specified, but the maximum resistance value of the conductor at 20 °C shall be increased by 5%. single Line may not be tinned or tin.

2.3.2 Spacer layer

It may be coated with a layer of suitable material of the spacer layer outside of each conductor.

GB/T 5013.5-2008/IEC 60245-5:1994

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 2 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 5013.5-2008

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
2 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 5013.5-2008

$35.00