Valid

GB/T 5013.3-2008Rubber insulated cables of rated voltages up to and including 450/750 V -- Part 3: Heat resistant silicone insulated cables (English PDF)

额定电压450/750V及以下橡皮绝缘电缆 第3部分:耐热硅橡胶绝缘电缆

Preview PDF

This is a limited preview

Buy now to download the full PDF (2 pages)

Need quotation for your management?

Get a formal quotation for GB/T 5013.3-2008 in 30 minutes.

Issued by

Standardization Administration of China

Level / Type

National · Recommended

Issue date

January 22, 2008

Implementation date

September 1, 2008

Scope

GB/T 5013.3-2008 is the English-translated version of 额定电压450/750V及以下橡皮绝缘电缆 第3部分:耐热硅橡胶绝缘电缆.

GB/T 5013.3-2008 — GB/T 5013 This section gives the rated voltage of 300/500V technical requirements for heat-resistant silicone rubber insulated cables. Each cable shall comply with the requirements and the specific requirements of this part of GB/T 5013.1 regulations.

Found what you need?

Document preview — GB/T 5013.3-2008

National Standard of the People's Republic of China

ICS
29.060.20
Classification
K 13
Replacing
GB 5013.3-1997

Issued by: Standardization Administration of China

Contents

  • Foreword
  • 1 Overview
  • 1.1 Scope
  • 1.2 Normative references
  • 2 Maximum conductor temperature of 180 °C heat-resistant silicone rubber insulated cables
  • 2.1 Model
  • 2.2 Rated voltage
  • 2.3 Structure

Foreword

GB/T 5013 "rated voltage 450/750V and below rubber insulated cable" is divided into eight sections.

--- Part 1. General requirements;

--- Part 2. Test methods;

--- Part 3. Heat resistant silicone rubber insulated cables;

--- Part 4. Cords and flexible cables;

--- Part 5. Lift cables;

--- Part 6. Arc welding cables;

--- Part 7. Heat resistant ethylene - vinyl acetate rubber insulated cables;

--- Part 8. Cords.

This section GB/T 5013 Part 3. This section identical with IEC 60245-3:1994 "rated voltage 450/750V and with Under rubber insulated cables - Part 3. Heat resistant silicone rubber insulated cables "(in English) and its amendments Amendment1.1997 (In English).

For ease of use, GB/T 5013 made this part of the following editorial changes.

"." --- With a decimal point instead of a comma as the decimal point, "";

--- Delete international standards foreword.

This section from the implementation date instead of GB 5013.3-1997.

This section of the main changes compared to GB 5013.4-1997 are as follows.

--- Table 1, increased the average outer diameter of the lower limit and the upper limit value of average outside diameter is reduced.

This part is proposed by the China Electrical Equipment Industrial Association.

This part of the National Standardization Technical Committee of wire and cable.

This part of the unit responsible for drafting. Shanghai Electric Cable Research Institute.

Participated in the drafting of this section. Hualing Cable Group Co., Ltd., Fujian Nanping Sun Cable Co., Ltd., Kunming cable stocks Parts Limited, Shanghai Nanyang Electric Wire Co., Ltd., Shanghai Nanyang Cable Co., Ltd., Tianjin Jinshan Electric Wire & Cable Co., Ltd.

1 Overview

1.1 Scope

GB/T 5013 This section gives the rated voltage of 300/500V technical requirements for heat-resistant silicone rubber insulated cables.

Each cable shall comply with the requirements and the specific requirements of this part of GB/T 5013.1 regulations.

1.2 Normative references

The following documents contain provisions which, through GB/T reference in this 5013 constitute provisions of this section. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section.

GB/T 2951.1-1997 cable insulation and sheathing materials test methods - Part 1. General Test Methods 1. Thick Degree and dimensions measuring --- mechanical tests (idt IEC 60811-1-1:1993) GB/T 2951.2-1997 cable insulation and sheathing materials test methods - Part 1. General test methods - Part 2. Hot Aging methods (idt IEC 60811-1-2. 1985) GB/T 2951.5-1997 cable insulation and sheathing materials test methods - Part 2. elastomeric compounds specific test side Act 1. Ozone resistance test --- --- Hot set test - Mineral oil immersion test (idt IEC 60811-2-1. 1986) GB/T 3956 cable conductor (GB/T 3956-1997, idt IEC 60228. 1978) GB/T 5013.1-2008 rated voltage of 450/750V and below rubber insulated cables - Part 1. General requirements (IEC 60245-1:2003, IDT) GB/T 5013.2-2008 rated voltage of 450/750V and below rubber insulated cables - Part 2. Test methods (IEC 60245-2:1998, IDT)

2 Maximum conductor temperature of 180 °C heat-resistant silicone rubber insulated cables

2.1 Model

60245IEC 03 (YG).

2.2 Rated voltage

300/500V.

2.3 Structure

2.3.1 Conductor

Number of cores. a core.

Conductor shall meet the requirements of GB/T 3956 in the fifth conductor requirements.

Single line can not tinned or tin, or plating of a metal other than tin, such as silver.

2.3.2 Spacer layer

Not even a single line or tin metal other than tin, whether the package around the conductor layer made of a suitable material for the isolation layer may optionally.

2.3.3 Insulation

Insulation shall be extruded in a single layer on the conductor IE2 silicone rubber mixture.

GB/T 5013.3-2008/IEC 60245-3:1994

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 2 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 5013.3-2008

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
2 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 5013.3-2008

$25.00