Valid

GB/T 12527-2008Aerial insulated cables for rated voltages up to and including 1kV (English PDF)

额定电压1 kV及以下架空绝缘电缆

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 12527-2008 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China

Level / Type

National · Recommended

Issue date

June 30, 2008

Implementation date

April 1, 2009

Scope

GB/T 12527-2008 is the English-translated version of 额定电压1 kV及以下架空绝缘电缆.

GB/T 12527-2008 is the Chinese national standard on aerial insulated cables for rated voltages up to and including 1kv, in the field of electrical engineering.

The /T suffix marks it as a recommended standard: it is not compulsory by itself, but it becomes binding as soon as a contract, a tender or a customer specification calls it up - which in practice is how most foreign buyers meet it.

It was issued on 30 June 2008 by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China, and has been in force since 1 April 2009.

Classification: ICS 29.060.20, CCS K13. This page is published from the official record of the standard held by the Chinese standards administration: the identification, the dates, the classification and the issuing body are taken from there.

The clause text, the tables and the numeric limits are in the document itself, which is delivered complete in English translation.

Found what you need?

Document preview — GB/T 12527-2008

National Standard of the People's Republic of China

ICS
29.060.20
Classification
K13

Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China

Contents

  • ForewordIII
  • 1 Scope1
  • 2 Normative references1
  • 3 Terms and definitions2
  • 4 Symbols and code2
  • 5 Using Features3
  • 6 Models, specifications3
  • 7 Technical requirements3
  • Test Method 87
  • 9 Acceptance Rule7
  • 10 Packaging, transportation and storage8
  • Appendix A (informative) Test Method for artificial weathering (xenon lamp method)10
  • Appendix B (normative) abrasion resistance test12

Foreword

This standard replaces GB 12527-1990 "rated voltage 1kV and below aerial insulated cables."

This standard compared with GB 12527-1990 main changes are as follows.

--- Modify the definition of the rated voltage (1990 version 3.4, 3.4 of this standard);

--- Modify the product representation (1990 version 3.7, 4.3 of this standard);

--- Increased aluminum and aluminum alloy conductor single core cable specifications 300mm2,400mm2 (see Table 2 and Table 4);

--- Removed the stranded conductor than a predetermined pitch diameter and twist to the (1990 version 7.1.2);

--- A sign of increased core method (see 7.2.2).

Appendix A of this standard is an informative annex, Annex B normative appendix.

The standard proposed by China Electrical Equipment Industrial Association.

This standard by the national wire and cable Standardization Technical Committee (SAC/TC213) centralized.

This standard is drafted by: Shanghai Electric Cable Research Institute.

Participated in the drafting of this standard. Shanghai Electric Cable Research Institute, Wuxi Jiangnan Cable Co., Ltd., Changshu Cable Factory, Fujian Nanping cable

Co., Ltd., Guangdong matt Cable Industry Co., Ltd., Wuhan second Wire and Cable Co., Ltd., Tianjin plastic power cable Group Limited.

Drafters of this standard. Qu Bo, Liu, Qian Feng, Chen Baokun, Luzhan Yu, Shen Yong, Han Zhangwu.

This standard superseded standard previously issued as follows.

Rated voltage Vp k 1 and below overhead insulated cables

1 Scope

This standard specifies the technical conditions for AC rated voltage 1kV and below aerial insulated cables, test methods, inspection rules, packaging,

Transportation and storage.

This standard applies to the rated AC voltage U 1kV and below overhead power lines with copper, aluminum, aluminum alloy core weatherproof polyvinyl chloride

, Polyethylene and cross-linked polyethylene insulated aerial cable.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent

Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research

Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.

GB/T 2900.10-2001 Electrotechnical terminology cable (idt IEC 60050-461. 1984)

GB/T 2951.1-1997 cable insulation and sheathing materials test methods - Part 1. General Test Methods 1. Thick Degree and dimensions measuring --- mechanical tests (idt IEC 60811-1-1.1993)

GB/T 2951.2-1997 cable insulation and sheathing materials test methods - Part 1. General test methods - Part 2. Hot Aging methods (idt IEC 60811-1-2. 1985No.1 (1989) 1st amendment)

GB/T 2951.3-1997 General test methods for cable insulation and sheathing materials - Part 1. General test method Section 3. secret Measurement Method --- --- Water absorption tests - Shrinkage test (idt IEC 60811-1-3.1993)

GB/T 2951.4-1997 cable insulation and sheathing materials test methods - Part 1. General test methods - Part 4. Low Temperature Test (idt IEC 60811-1-4. 1985No.1 (1993) 1st amendment)

GB/T 2951.5-1997 cable insulation and sheathing materials test methods - Part 2. General test elastomeric compounds Party Act 1. Ozone resistance test --- --- Hot set test - Mineral oil immersion test (idt IEC 60811-2-1. 1986No.1 (1992) 1 Amendment No. 2 (1993) 2nd amendment)

GB/T 2951.6-1997 cable insulation and sheathing materials test methods - Part 3. Test specific to PVC compounds Methods Section 1. Pressure test --- high temperature resistance to cracking (idt IEC 60811-3-1. 1985No.1 (1994) 1st amendment)

GB/T 2951.7-1997 cable insulation and sheathing materials test methods - Part 3. Test specific to PVC compounds

Remaining clauses in the full document

  • 3 Terms and definitions
  • 4 Symbols and code
  • 5 Using Features
  • 6 Models, specifications
  • 7 Technical requirements
  • 9 Acceptance Rule
  • 10 Packaging, transportation and storage

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Normative references

IEC 60050 · GB/T 2951.1-1997 · IEC 60811 · GB/T 2951.2-1997 · GB/T 2951.3-1997 · GB/T 2951.4-1997 · GB/T 2951.5-1997 · GB/T 2951.6-1997 · GB/T 2951.7-1997 · IEC 60060 · ISO 1133

Similar standards

Editions of GB/T 12527

EditionTitleRevisionStatus
GB/T 12527-2008Aerial insulated cables for rated voltages up to and including 1kVcurrent editionCurrent
GB 12527-1990Aerial insulated cables of rated voltages up to and including 1 kVmerged into this editionSuperseded

This page sells the current edition, GB/T 12527-2008. Earlier editions are listed for reference only.

How to Download GB/T 12527-2008

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 12527-2008

$85.00