GB/T 12527-2008Aerial insulated cables for rated voltages up to and including 1kV (English PDF)
额定电压1 kV及以下架空绝缘电缆
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 12527-2008 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China
Level / Type
National · Recommended
Issue date
June 30, 2008
Implementation date
April 1, 2009
Scope
GB/T 12527-2008 is the English-translated version of 额定电压1 kV及以下架空绝缘电缆.
GB/T 12527-2008 is the Chinese national standard on aerial insulated cables for rated voltages up to and including 1kv, in the field of electrical engineering.
The /T suffix marks it as a recommended standard: it is not compulsory by itself, but it becomes binding as soon as a contract, a tender or a customer specification calls it up - which in practice is how most foreign buyers meet it.
It was issued on 30 June 2008 by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China, and has been in force since 1 April 2009.
Classification: ICS 29.060.20, CCS K13. This page is published from the official record of the standard held by the Chinese standards administration: the identification, the dates, the classification and the issuing body are taken from there.
The clause text, the tables and the numeric limits are in the document itself, which is delivered complete in English translation.
Found what you need?
Document preview — GB/T 12527-2008
National Standard of the People's Republic of China
- ICS
- 29.060.20
- Classification
- K13
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China
Contents
- ForewordIII
- 1 Scope1
- 2 Normative references1
- 3 Terms and definitions2
- 4 Symbols and code2
- 5 Using Features3
- 6 Models, specifications3
- 7 Technical requirements3
- Test Method 87
- 9 Acceptance Rule7
- 10 Packaging, transportation and storage8
- Appendix A (informative) Test Method for artificial weathering (xenon lamp method)10
- Appendix B (normative) abrasion resistance test12
Foreword
This standard replaces GB 12527-1990 "rated voltage 1kV and below aerial insulated cables."
This standard compared with GB 12527-1990 main changes are as follows.
--- Modify the definition of the rated voltage (1990 version 3.4, 3.4 of this standard);
--- Modify the product representation (1990 version 3.7, 4.3 of this standard);
--- Increased aluminum and aluminum alloy conductor single core cable specifications 300mm2,400mm2 (see Table 2 and Table 4);
--- Removed the stranded conductor than a predetermined pitch diameter and twist to the (1990 version 7.1.2);
--- A sign of increased core method (see 7.2.2).
Appendix A of this standard is an informative annex, Annex B normative appendix.
The standard proposed by China Electrical Equipment Industrial Association.
This standard by the national wire and cable Standardization Technical Committee (SAC/TC213) centralized.
This standard is drafted by: Shanghai Electric Cable Research Institute.
Participated in the drafting of this standard. Shanghai Electric Cable Research Institute, Wuxi Jiangnan Cable Co., Ltd., Changshu Cable Factory, Fujian Nanping cable
Co., Ltd., Guangdong matt Cable Industry Co., Ltd., Wuhan second Wire and Cable Co., Ltd., Tianjin plastic power cable Group Limited.
Drafters of this standard. Qu Bo, Liu, Qian Feng, Chen Baokun, Luzhan Yu, Shen Yong, Han Zhangwu.
This standard superseded standard previously issued as follows.
Rated voltage Vp k 1 and below overhead insulated cables
1 Scope
This standard specifies the technical conditions for AC rated voltage 1kV and below aerial insulated cables, test methods, inspection rules, packaging,
Transportation and storage.
This standard applies to the rated AC voltage U 1kV and below overhead power lines with copper, aluminum, aluminum alloy core weatherproof polyvinyl chloride
, Polyethylene and cross-linked polyethylene insulated aerial cable.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent
Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research
Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 2900.10-2001 Electrotechnical terminology cable (idt IEC 60050-461. 1984)
GB/T 2951.1-1997 cable insulation and sheathing materials test methods - Part 1. General Test Methods 1. Thick Degree and dimensions measuring --- mechanical tests (idt IEC 60811-1-1.1993)
GB/T 2951.2-1997 cable insulation and sheathing materials test methods - Part 1. General test methods - Part 2. Hot Aging methods (idt IEC 60811-1-2. 1985No.1 (1989) 1st amendment)
GB/T 2951.3-1997 General test methods for cable insulation and sheathing materials - Part 1. General test method Section 3. secret Measurement Method --- --- Water absorption tests - Shrinkage test (idt IEC 60811-1-3.1993)
GB/T 2951.4-1997 cable insulation and sheathing materials test methods - Part 1. General test methods - Part 4. Low Temperature Test (idt IEC 60811-1-4. 1985No.1 (1993) 1st amendment)
GB/T 2951.5-1997 cable insulation and sheathing materials test methods - Part 2. General test elastomeric compounds Party Act 1. Ozone resistance test --- --- Hot set test - Mineral oil immersion test (idt IEC 60811-2-1. 1986No.1 (1992) 1 Amendment No. 2 (1993) 2nd amendment)
GB/T 2951.6-1997 cable insulation and sheathing materials test methods - Part 3. Test specific to PVC compounds Methods Section 1. Pressure test --- high temperature resistance to cracking (idt IEC 60811-3-1. 1985No.1 (1994) 1st amendment)
GB/T 2951.7-1997 cable insulation and sheathing materials test methods - Part 3. Test specific to PVC compounds
Remaining clauses in the full document
- 3 Terms and definitions
- 4 Symbols and code
- 5 Using Features
- 6 Models, specifications
- 7 Technical requirements
- 9 Acceptance Rule
- 10 Packaging, transportation and storage
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 2900.10-2001Electrotechnical terminology -- Electric cables
- GB/T 3048.4-2007Test methods for electrical properties of electric cables and wires — Part 4: Test of DC resistance of conductors
- GB/T 3048.5-2007Test methods for electrical properties of electric cables and wires - Part 5: Test of insulation resistance
- GB/T 3048.8-2007Test methods for electrical properties of electric cables and wires - Part 8: AC voltage test
- GB/T 3048.9-2007Test methods for electrical properties of electric cables and wires - Part 9: Spark test of insulated cores
- GB/T 3682-2000Determination of the melt mass-flow rate (MFR) and the melt volume-flow rate (MVR) of thermoplastics
IEC 60050 · GB/T 2951.1-1997 · IEC 60811 · GB/T 2951.2-1997 · GB/T 2951.3-1997 · GB/T 2951.4-1997 · GB/T 2951.5-1997 · GB/T 2951.6-1997 · GB/T 2951.7-1997 · IEC 60060 · ISO 1133
Cited by
- GB/T 15065-2026Polyethylene compounds for wires and cables
- GB/T 30600-2022Well-facilitated farmland construction—General rules
- GB/T 33766-2017Technical requirements for independent energy of solar photovoltaic system
- NB/T 42051-2015Cross-linked polyethylene insulated cables with aluminum alloy conductor for rated voltage of 0.6/1kV
Similar standards
Editions of GB/T 12527
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 12527-2008 | Aerial insulated cables for rated voltages up to and including 1kV | current edition | Current |
| GB 12527-1990 | Aerial insulated cables of rated voltages up to and including 1 kV | merged into this edition | Superseded |
This page sells the current edition, GB/T 12527-2008. Earlier editions are listed for reference only.
How to Download GB/T 12527-2008
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 12528-2008 — Rail vehicle cables with rated voltages up to and including 3kV
GB/T 12706.1-2020 — Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um=1.2 kV) up to 35 kV (Um=40.5 kV) - Part 1: Cables for rated voltage of 1 kV (Um=1.2 kV) and 3 kV (Um=3.6 kV)
GB/T 12706.3-2020 — Power cables with extruded insulation and their accessories for rated voltages from 1kV (Um=1.2kV) up to 35kV (Um=40.5kV) - Part 3: Cables for rated voltages of 35kV(Um=40.5kV)
Secure payment via Stripe
Payments accepted
GB/T 12527-2008
$85.00