GB/T 5023.4-2008Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V -- Part 4: Sheathed cables for fixed wiring (English PDF)
额定电压450/750V及以下聚氯乙烯绝缘电缆 第4部分:固套电缆
This is a limited preview
Buy now to download the full PDF (3 pages)
Need quotation for your management?
Get a formal quotation for GB/T 5023.4-2008 in 30 minutes.
Issued by
Standardization Administration of China
Level / Type
National · Recommended
Issue date
June 30, 2008
Implementation date
May 1, 2009
Scope
GB/T 5023.4-2008 is the English-translated version of 额定电压450/750V及以下聚氯乙烯绝缘电缆 第4部分:固套电缆.
GB/T 5023.4-2008 — GB/T 5023 this part of the detailed provisions of the rated voltage of 300/500V technical requirements for light PVC sheathed cable. All cables shall comply with applicable requirements and special requirements of this part of GB/T 5023.1 regulations.
Found what you need?
Document preview — GB/T 5023.4-2008
National Standard of the People's Republic of China
- ICS
- 29.060.20
- Classification
- K 13
- Replacing
- GB 5023.4-1997
Issued by: Standardization Administration of China
Contents
- Foreword
- 1 General
- 1.1 Scope
- 1.2 Normative references
- 2 Light PVC sheathed cable
- 2.1 Model
- 2.2 Rated voltage
Foreword
GB/T 5023 "rated voltage 450/750V and below PVC insulated cables" is divided into seven parts.
--- Part 1. General requirements;
--- Part 2. Test methods;
--- Part 3. Non-sheathed cables for fixed wiring;
--- Part 4. Sheathed cables for fixed wiring;
--- Part 5. Flexible cables (cords);
--- Part 6. Lift cables and cables for flexible connection;
--- Part 7. two-core or multi-core shielded and unshielded cable.
This section GB/T 45023 Part of. This section identical with IEC 60227-4:1997 "rated voltage 450/750V and with Under PVC insulated cables Part 4. Sheathed cables for fixed wiring "Version 2.1 (in English).
For ease of use, GB/T 5023 made this part of the following editorial changes.
"." --- With a decimal point instead of a comma as the decimal point, "";
--- Remove the IEC 60227-4:1997 Foreword.
This Part replaces GB 5023.4-1997 "rated voltage 450/750V and below PVC insulated cables Part 4. Fixed cloth Sheathed cable line. " this section of the main changes compared to GB 5023.4-1997 are as follows.
--- Normative references added to the following documents.
IEC 60719:1992 rated voltage 450/750V and below average round copper conductor cable outer diameter of upper and lower limits of computing method;
--- Table 1 Table Added note. The 1992 regulations. IEC 60719 calculation of the lower limit of the average non-compliance on the outer diameter of the cable.
This part is proposed by the China Electrical Equipment Industrial Association.
This part of the National Standardization Technical Committee Wire and Cable (SAC/TC213) centralized.
This part of the unit responsible for drafting. Shanghai Electric Cable Research Institute.
Participated in the drafting of this section. Far East Cable Factory, Tianjin Jinshan Electric Wire & Cable Co., Ltd., Jiang Su Shengan Cable Co., Ltd., Nanchang Cable Co., Ltd., Jiangsu on the cable Group Co., Ltd., Hunan Cable Co., Ltd. Gold can.
1 General
1.1 Scope
GB/T 5023 this part of the detailed provisions of the rated voltage of 300/500V technical requirements for light PVC sheathed cable.
All cables shall comply with applicable requirements and special requirements of this part of GB/T 5023.1 regulations.
1.2 Normative references
The following documents contain provisions which, through GB/T reference in this 5023 constitute provisions of this part. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section.
GB/T 2951.11-2008 cable and the cable Common test methods for insulating and sheathing materials - Part 11. General test side Law --- --- Measurement of thickness and overall dimensions of mechanical tests (IEC 60811-1-1:2001, IDT) GB/T 2951.12-2008 cable and the cable Common test methods for insulating and sheathing materials - Part 12. General test side Law --- Thermal aging methods (IEC 60811-1-2. 1985, IDT) GB/T 2951.14-2008 cable and the cable Common test methods for insulating and sheathing materials - Part 14. General test side Law --- Low temperature test (IEC 60811-1-4. 1985, IDT) GB/T 2951.31-2008 cable and the cable Common test methods for insulating and sheathing materials - Part 31. Polyvinyl chloride mixture Methods specific high temperature pressure test --- --- resistance to cracking (IEC 60811-3-1. 1985, IDT) GB/T 2951.32-2008 cable and the cable Common test methods for insulating and sheathing materials - Part 32. Polyvinyl chloride mixture Special test methods --- --- Loss of mass test - Thermal stability test (IEC 60811-3-2. 1985, IDT) GB/T 3956-1997 cable conductor (idt, IEC 60228. 1978) GB/T 5023.1 rated voltage of 450/750 V and below PVC insulated cables - Part 1. General requirements (GB/T 5023.1-2008, IEC 60227-1:2007, IDT) GB/T 5023.2-2008 rated voltage of 450/750V or less PVC insulation - Part 2. Test methods (IEC 60227-2:2003, IDT) GB/T 18380.12-2008 burning test and optical fiber cables under fire conditions - Part 12. single insulated wire and cable fire Vertical flame spread test (IEC 60332-1-2:2004, IDT) IEC 60719:1992 rated voltage 450/750V or less round average outer upper and lower copper conductor cable and calculation method
2 Light PVC sheathed cable
2.1 Model
60227IEC 10 (BVV).
2.2 Rated voltage
300/500V.
GB/T 5023.4-2008/IEC 60227-4:1997
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 3 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 2951.11-2008Common test methods for insulating and sheathing materials of electric and optical cables -- Part 11: Methods for general application -- Measurement of thickness and overall dimensions -- Tests for determining the mechanical properties
- GB/T 2951.12-2008Common test methods for insulating and sheathing materials of electric and optical cables -- Part 12: Methods for general application -- Thermal ageing methods
- GB/T 2951.14-2008Common test methods for insulating and sheathing materials of electric and optical cables -- Part 14: Methods for general application -- Test at low temperature
- GB/T 2951.31-2008Common test methods for insulating and sheathing materials of electric and optical cables -- Part 31: Methods specific to PVC compounds -- Pressure test at high temperature -- Test for resistance to cracking
- GB/T 2951.32-2008Common test methods for insulating and sheathing materials of electric and optical cables -- Part 32: Methods specific to PVC compounds -- Loss of mass test -- Thermal stability test
- GB/T 3956-1997Conductors of insulated cables
IEC 60811 · IEC 60228 · IEC 60227 · IEC 60332 · IEC 60719
Cited by
- GB/T 11918.1-2025Plugs, fixed or portable socket-outlets and appliance inlets for industrial purposes - Part 1: General requirements
- GB/T 35857-2018Safety rules for the construction and installation of electric lifts with inclined path
- GB/T 11918.1-2014Plugs, socket-outlets and couplers for industrial purposes -- Part 1: General requirements
- JB/T 12023-2014250 A~630 A Plugs, Socket-outlets and Couplers for Industrial Purposes
- JB/T 10254-2013Technical requirements for stators and rotors of single-phase series motors for electric tools
- GB 16899-2011Safety rules for the construction and installation of escalators and moving walks
How to Download GB/T 5023.4-2008
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 18380.12-2008 — Test on electric and optical fibre cables under fire conditions -- Part 12: Test for vertical flame propagation for a single insulated wire or cable -- Procedure for 1kW pre-mixed flame
GB/T 2951.11-2008 — Common test methods for insulating and sheathing materials of electric and optical cables -- Part 11: Methods for general application -- Measurement of thickness and overall dimensions -- Tests for determining the mechanical properties
GB/T 2951.12-2008 — Common test methods for insulating and sheathing materials of electric and optical cables -- Part 12: Methods for general application -- Thermal ageing methods
Secure payment via Stripe
Payments accepted
GB/T 5023.4-2008
$75.00