GB/T 5023.2-2008Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V -- Part 2: Test methods (English PDF)
额定电压450/750V及以下聚氯乙烯绝缘电缆 第2部分:试验方法
This is a limited preview
Buy now to download the full PDF (5 pages)
Need quotation for your management?
Get a formal quotation for GB/T 5023.2-2008 in 30 minutes.
Issued by
Standardization Administration of China
Level / Type
National · Recommended
Issue date
June 30, 2008
Implementation date
May 1, 2009
Scope
GB/T 5023.2-2008 is the English-translated version of 额定电压450/750V及以下聚氯乙烯绝缘电缆 第2部分:试验方法.
GB/T 5023.2-2008 — Test Method GB/T 5023 as stipulated in the various parts are listed in this section and the following criteria. GB/T 2951.11-2008 cable and the cable Common test methods for insulating and sheathing materials - Part 11.
General test side Law --- --- Measurement of thickness and overall dimensions of mechanical tests (IEC 60811-1-1:2001, IDT) GB/T 5023.1-2008 rated voltage of 450/750V and below PVC insulated cables - Part 1.
General requirements (IEC 60227-1:2007, IDT) GB/T 18380.12-2008 burning test and optical fiber cables under fire conditions - Part 12. single insulated wire and cable fire Vertical flame spread test (IEC 60332-1-2:2004, IDT)
Found what you need?
Document preview — GB/T 5023.2-2008
National Standard of the People's Republic of China
- ICS
- 29.060.20
- Classification
- K 13
- Replacing
- GB 5023.2-1997
Issued by: Standardization Administration of China
Contents
- Foreword
- 1 General
- 1.1 General Requirements
- 1.2 Application Test
- 1.3 Test by frequency classification
- 1.4 Sampling
- 1.5 Pretreatment
- 1.6 Test temperature
- 1.9 Insulation thickness measurement
Foreword
GB/T 5023 "rated voltage 450/750V and below PVC insulated cables" is divided into seven parts.
--- Part 1. General requirements;
--- Part 2. Test methods;
--- Part 3. Non-sheathed cables for fixed wiring;
--- Part 4. Sheathed cables for fixed wiring;
--- Part 5. Flexible cables (cords);
--- Part 6. Lift cables and cables for flexible connection;
--- Part 7. two-core or multi-core shielded and unshielded cable.
This section GB/T 5023 Part 2. This section identical with IEC 60227-2:2003 "rated voltage 450/750V and with Under PVC insulated cables - Part 2. Test methods "Version 2.1 (in English).
For ease of use, GB/T 5023 made this part of the following editorial changes.
"." --- With a decimal point instead of a comma as the decimal point, "";
--- Remove the IEC 60227-2:2003 Foreword;
--- Deleted 2.3, Table 1 and 3.4 "flat non-sheathed cord," the relevant content.
This Part replaces GB 5023.2-1997 "rated voltage 450/750V or less PVC insulation - Part 2. Test side law".
This section of the main changes compared to GB 5023.2-1997 are as follows.
--- 1.9.1 The abolition of the "period of the insulated core sample is immersed in mercury until the insulation becomes flabby, out of the conductor can" approach;
--- Deleted 2.3, Table 1 and 3.4 "flat non-sheathed cord" related content ";
--- 3.1 scratch test made the following modifications.
1) 3.1.1 General modified to "This test does not apply to wire core nominal cross-sectional area greater than 2.5mm2 multi-core flexible cables";
2) 3.1.2 Flexing test instrument has been described;
3) Table 1 cable cores 3.1.3 sample preparation increases core 2,3,4, 2,3,4 and provides core nominal cross-sectional area of \u200b\u200b0.5mm2 Cable hanging weight of 0.5kg, the pulley diameter of 60mm;
4) increase the 3.1.4 core carrier test;
5) increasing the core voltage test between 3.1.5;
6) increasing the inspection failure 3.1.6.
--- Increased 3.5 Flexing static test;
--- Increased by 3.6 elevator cable central pad core tensile strength test.
This part is proposed by the China Electrical Equipment Industrial Association.
This part of the National Standardization Technical Committee Wire and Cable (SAC/TC213) centralized.
This part of the unit responsible for drafting. Shanghai Electric Cable Research Institute.
Participated in the drafting of this section. Jiangsu on the cable Group Co., Ltd., Changshu Cable Factory, Fujian Nanping Sun Cable Co., Ltd., Shanghai Panda Cable Co., Ltd., Jiang Su Shengan Cable Co., Ltd., Shanghai Old Port Cable Co., Ltd. Shanghai Ling Electronics.
1 General
1.1 General Requirements
Test Method GB/T 5023 as stipulated in the various parts are listed in this section and the following criteria.
GB/T 2951.11-2008 cable and the cable Common test methods for insulating and sheathing materials - Part 11. General test side Law --- --- Measurement of thickness and overall dimensions of mechanical tests (IEC 60811-1-1:2001, IDT) GB/T 5023.1-2008 rated voltage of 450/750V and below PVC insulated cables - Part 1. General requirements (IEC 60227-1:2007, IDT) GB/T 18380.12-2008 burning test and optical fiber cables under fire conditions - Part 12. single insulated wire and cable fire Vertical flame spread test (IEC 60332-1-2:2004, IDT)
1.2 Application Test
Various types of cable products by the applicable test standard (GB/T 5023.3, GB/T 5023.4, etc.) rules.
1.3 Test by frequency classification
According to GB/T 5023.1-2008 defined in 2.2, the test is defined as type tests (symbol T) and (or) sample test (symbol S) two kinds.
Symbol T and S for use in product standards (GB/T 5023.3, GB/T 5023.4, etc.) related to the tables.
1.4 Sampling
If the use of insulation or jacket embossed Braille signs, sampling should include this flag.
Unless otherwise specified, for multi-core cables, in addition to the test specified in 1.9, the sample should be taken no more than three cores (if separations, take a different color) experimenting.
1.5 Pretreatment
All tests should be in the insulation or jacketing storage be carried out after at least 16h.
1.6 Test temperature
Unless otherwise specified, the tests should be carried out at ambient temperature.
1.7 The test voltage Unless otherwise specified, the test voltage should be approximately sinusoidal AC 49Hz ~ 61Hz, the ratio is equal to the peak and rms Sang 2 (1 ± 7%).
Voltage are RMS.
Rub resistance and color inspection logo 1.8 Application of a group of water-soaked absorbent cotton or a cotton cloth and gently wipe the manufacturer's name or trademark, or insulated wire core color digital signs, a total wipe 10 times, the test results should meet the standard requirements.
1.9 Insulation thickness measurement
1.9.1 Step
Insulation thickness shall GB/T 2951.11-2008 measured as specified in 8.1, should be separated from each section of cable at least 1m of three Sample.
GB/T 5023.2-2008/IEC 60227-2:2003
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 5 pages — is available in the English PDF.
Referenced standards
Cited by
- GB/T 11918.1-2025Plugs, fixed or portable socket-outlets and appliance inlets for industrial purposes - Part 1: General requirements
- GB/T 20965-2025Control network HBES technical specification - Home and building control system
- GB/T 11918.1-2014Plugs, socket-outlets and couplers for industrial purposes -- Part 1: General requirements
- JB/T 10261-2014Polyvinyl Chloride Insulated and Nylon Sheathed Wires and Cables with Rated Voltages up to and Including 450/750 V
- JB/T 12023-2014250 A~630 A Plugs, Socket-outlets and Couplers for Industrial Purposes
- JB/T 10254-2013Technical requirements for stators and rotors of single-phase series motors for electric tools
How to Download GB/T 5023.2-2008
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 5023.1-2008 — Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 1: General requirements
GB/T 5023.3-2008 — Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V -- Part 3: Non-sheathed cables for fixed wiring
GB/T 5023.5-2008 — Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V -- Part 5: Flexible cables (cords)
Secure payment via Stripe
Payments accepted
GB/T 5023.2-2008
$75.00