GB/T 5023.3-2008Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V -- Part 3: Non-sheathed cables for fixed wiring (English PDF)
Also coversGBT5023.3-2008
This is a limited preview
Buy now to download the full PDF (5 pages)
Need quotation for your management?
Get a formal quotation for GB/T 5023.3-2008 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine
Level / Type
National · Recommended
Issue date
June 30, 2008
Implementation date
May 1, 2009
Scope
GB/T 5023.3-2008 (Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V -- Part 3: Non-sheathed cables for fixed wiring) is available as an English-translated PDF.
GB/T 5023.3-2008 - This Part of GB/T 5023 details the particular specifications for polyvinyl chloride insulated single-core non-sheathed cables for fixed wiring and rated voltages up to and including 450/750V.
All cables shall comply with the appropriate requirements given in GB/T 5023.1, and the individual types of cables shall each comply with the particular requirements of this Part.
Found what you need?
Document preview — GB/T 5023.3-2008
National Standard of the People's Republic of China
- ICS
- 29.060.20
- Classification
- K 13
Issued by: General Administration of Quality Supervision, Inspection and Quarantine
Contents
- Foreword...3
- 1 General...5
Foreword
GB/T 5023 Polyvinyl Chloride Insulated Cables of Rated Voltages up to and Including
450/750V is divided into 7 parts.
--- Part 1.General Requirements;
--- Part 2.Test Methods;
--- Part 3.Non-Sheathed Cables for Fixed Wiring;
--- Part 4.Sheathed Cables for Fixed Wiring;
--- Part 5.Soft Cables (Soft Wires);
--- Part 6.Lift Cables and Cables for Flexible Connections;
--- Part 7.Flexible Cables Screened and Unscreened with Two or More
Conductors.
This Part is Part 3 of GB/T 5023.This Part equivalently adopts IEC 60227-3.1997
Polyvinyl Chloride Insulated Cables of Rated Voltages up to and Including 450/750V –
Part 3.Non-Sheathed Cables for Fixed Wiring, Version 2.1 (English Edition).
For ease of use, this Part of GB/T 5023 makes the following editorial changes.
--- Use "decimal point" to replace the "comma" that acts as the decimal point
--- Delete the Foreword of IEC 60227-3.1997.
This Part replaces GB 5023.3-1997 Polyvinyl Chloride Insulated Cables of Rated
Voltages up to and Including 450/750V.
Compared with GB 5023.3-1997, this Part mainly has the following changes.
--- Regulate the upper- and lower-limit against the overall diameter of 60227 IEC
Model 01, 02, 05, 06, 07, 08, and other types of cables; adjust the upper limit of
diameter of cables in the original standard (Table 1, 3, 5, 7, 9, 11);
--- Modify 60227 IEC Model 01-type cable's 35mm2 and 50mm2 minimum
insulation resistance; 35mm2 corresponding minimum insulation resistance of
0.0040 Mohm·km was changed into 0.0043 Mohm·km; while 50mm2 corresponding
minimum insulation resistance of 0.0045 Mohm·km was changed into 0.0043
Mohm·km.
This Part was proposed by China Electrical Equipment Industrial Association.
Polyvinyl Chloride Insulated Cables of Rated Voltages
up to and Including 450/750V – Part 3.Non-Sheathed
Cables for Fixed Wiring
1 General
1.1 Scope
This Part of GB/T 5023 details the particular specifications for polyvinyl chloride
insulated single-core non-sheathed cables for fixed wiring and rated voltages up to
and including 450/750V.
All cables shall comply with the appropriate requirements given in GB/T 5023.1, and
the individual types of cables shall each comply with the particular requirements of
this Part.
1.2 Normative references
The following normative documents contain provisions which, through reference in
this text, constitute provisions of this part of GB/T 5023.For dated references, the
subsequent amendments (excluding corrigendum) or revisions do not apply to this
Part, however, parties who reach an agreement based on this Part are encouraged to
study if the latest versions of these documents are applicable. For undated references,
the latest edition of the referenced document applies.
GB/T 2951.11-2008 Common Test Methods for Insulating and Sheathing Materials
of Electric and Optical Cables - Part 11.Methods for General Application -
Measurement of Thickness and Overall Dimensions (IEC 60811-1-1.2001, IDT)
GB/T 2951.12-2008 Common Test Methods for Insulating and Sheathing
Materials of Electric and Optical Cables - Part 12.Methods for General Application
- Thermal Ageing Methods (IEC 60811-1-2.1985, IDT)
GB/T 2951.14-2008 Common Test Methods for Insulating and Sheathing
Materials of Electric and Optical Cables - Part 14.Methods for General Application
- Test at Low Temperature (IEC 60811-1-4.1985, IDT)
GB/T 2951.31-2008 Common Test Methods for Insulating and Sheathing
Materials of Electric and Optical Cables - Part 31.Methods Specific to PVC
Compounds - Pressure Test at High Temperature - Test for Anti-Crack (IEC
60811-3-1.1985, IDT)
GB/T 2951.32-2008 Common Test Methods for Insulating and Sheathing
Materials of Electric and Optical Cables - Part 32.Methods Specific to PVC
Compounds - Loss of Mass Test - Thermal Stability Test (IEC 60811-3-2.1985,
IDT)
GB/T 3956-1997 Conductors Of Insulated Cables (idt IEC 60228.1978)
GB/T 5023.1 Polyvinyl Chloride Insulated Cables of Rated Voltages up to and
Including 450/750V - Part 1.General Requirements (GB/T 5023.1-2008, IEC
60227-1.2007, IDT)
GB/T 5023.2-2008 Polyvinyl Chloride Insulated Cables of Rated Voltages up to
and Including 450/750V - Part 2.Test Methods (IEC 60227-2.2003, IDT)
GB/T 18380.12-2008 Test on Electric and Optical Fiber Cables under Fire
Conditions - Part 12.Test for Vertical Flame Propagation for a Single Insulated
Wire or Cable (IEC 60332-1-2.2004, IDT)
2 Single-Core Non-Sheathed Cable with Rigid
Conductor for General Purposes
2.1 Code designation
60227 IEC 01 (BV).
2.2 Rated voltage
450/750V.
2.3 Construction
2.3.1 Conductor
Number of cores. 1.
The conductors shall comply with the requirements of GB/T 3956-1997.
--- Class 1 for solid conductors;
--- Class 2 for stranded conductors.
2.3.2 Insulation
The extruded insulation shall be polyvinyl chloride compound of Type PVC/C applied
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 5 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 3956-1997Conductors of insulated cables
- GB/T 5023.1Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 1: General requirements
- GB/T 5023.1-2008Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 1: General requirements
- GB/T 18380.12-2008Tests on electric and optical fibre cables under fire conditions—Part 12:Test for vertical flame propagation for a single insulated wire or cable—Procedure for 1 kW pre-mixed flame
GB/T 5023 · GB/T 2951.11-2008 · IEC 60811 · GB/T 2951.12-2008 · GB/T 2951.14-2008 · GB/T 2951.31-2008 · GB/T 2951.32-2008 · IEC 60228.1978 · GB/T 5023.2-2008 · IEC 60227 · IEC 60332
Cited by
- GB/T 11918.1-2025Plugs, fixed or portable socket-outlets and appliance inlets for industrial purposes - Part 1: General requirements
- GB/T 35857-2018Safety rules for the construction and installation of electric lifts with inclined path
- GB/T 11918.1-2014Plugs, socket-outlets and couplers for industrial purposes -- Part 1: General requirements
- JB/T 12023-2014250 A~630 A Plugs, Socket-outlets and Couplers for Industrial Purposes
- JB/T 10254-2013Technical requirements for stators and rotors of single-phase series motors for electric tools
- JB/T 7082-2013Dielectric withstand voltage testers
How to Download GB/T 5023.3-2008
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 18380.12-2008 — Test on electric and optical fibre cables under fire conditions -- Part 12: Test for vertical flame propagation for a single insulated wire or cable -- Procedure for 1kW pre-mixed flame
GB/T 5023.1-2008 — Polyvinyl chloride insulated cables of rated voltages up to and including 450/750 V - Part 1: General requirements