GB 29410-2012Domestic dimethyl ether gas cooking appliances (English PDF)
家用二甲醚燃气灶
Open the GB 29410-2012 preview as PDF
This is a limited preview
Buy now to download the full PDF (23 pages)
Issued by
AQSIQ; SAC
Level / Type
National · Mandatory
Issue date
December 31, 2012
Implementation date
December 1, 2013
Scope
GB 29410-2012 is the English-translated version of 家用二甲醚燃气灶.
China's national standard for domestic cooking appliances burning dimethyl ether, the DME that is distributed as a bottled fuel in parts of the country and that attacks the elastomers and light alloys used in ordinary LPG appliances. It sets the classification and models, the requirements, the test methods, the inspection rules, and the marking, packaging, transport and storage. It applies to household DME cookers fed by the gas defined in GB 25035 whose nominal heat input per burner is not more than 5.23 kW; it does not apply to cookers used aboard moving vehicles or vessels, nor to combined gas and electric cookers. Large parts of the requirements are compulsory rather than recommended - among them the provisions on the gas circuit, the burners, the flame supervision device, the ignition, the electrical safety and the whole of the inspection rules and marking clauses, together with Tables 1, 2 and 4. The appliance must satisfy the general safety requirements for gas burning appliances of GB 16914, and an informative annex maps this standard's terms onto the basic requirements of that one. The materials clauses draw on the cable standards GB/T 5013.4 and GB/T 5023.3 and on the coated glass and ceramic panel specifications CJ/T 157 and CJ/T 305. Issued on 31 December 2012 and in force since 1 December 2013, it is a first edition, proposed by the Ministry of Housing and Urban-Rural Development.
Document preview — GB 29410-2012
National Standard of the People's Republic of China
- ICS
- 97.040.20
- Classification
- P 45
Issued by: General Administration of Quality Supervision, Inspection and Quarantine; Standardization Administration of the PRC
Contents
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 Flame Flame uniform homogeneity
- 4.1 Classification
- 5 Requirements
- 5.1 The basic design parameters
- 5.2 Structure
- 5.2.1 General requirements
- 5.2.2 Structure Parts
- 5.2.3 AC power for the ignition device of the gas stove structure
- 5.3 Material
- 5.3.1 General Requirements material
- 5.3.2 Sealing material
- 5.3.3 Burner
- 5.4 Performance
- 6 Test methods
- 6.1 Test conditions
- 6.1.1 Laboratory conditions According to the provisions in
- 6.1.2 Test System
- 6.1.3 The test gas
- 6.1.5 Test Equipment Test equipment to perform as specified in Table 7. Table
- 17 Reference
- 20 The valve housing 3 a 50 4 electric ignition device housing a
Foreword
5.2.1.5 of this standard, section 5.2.1.8, Article 5.2.1.9, Article 5.2.2.6a), Article 5.2.2.6b), Article 5.2.2.7f) , Article 5.2.2.8c), Article 5.2.2.11a), Article 5.2.3, Article 5.3.2, section 5.3.3.1, Article 5.4.1, section 5.4.2a) , Article 5.4.2c), Article 5.4.5, Section 5.4.6, section 5.4.7.1b), Article 5.4.7.2, Section 5.4.9, section 5.4.10, Rule 8.1 [except 8.1.1f) outside], Section 8.2.1, Table 1, Table 2, Table 4, bold portions are mandatory, the rest are recommended. This standard was drafted in accordance with rules GB/T 1.1-2009 given. Appendix A gives the standard terms to support the basic requirements GB 16914-2012 correspondence table. The standard proposed by the People's Republic of China Ministry of Housing and Urban-Rural Development. This standard by the Ministry of Housing and Urban town gas standard technical focal point. Drafted. North China Municipal Engineering Design & Research Institute, Zhongshan Vantage Gas Appliance Co., Ltd., has Jiutai Energy Technology Limited, Schindler Technology Group Co., Ltd., Zhejiang Jiangxin Tao Electronic Machinery Co., Ltd., the national gas appliances Quality Supervision and Inspection center. The main drafters. Zhang Circle, Chen Jin Rui, Yi Hongbin, Li Qi, Wu Binjiang, He Minghui, Qu Yanhong, Yan Rongsong. Household dimethyl ether gas stove
1 Scope
China's national standard for domestic cooking appliances burning dimethyl ether, the DME that is distributed as a bottled fuel in parts of the country and that attacks the elastomers and light alloys used in ordinary LPG appliances. It sets the classification and models, the requirements, the test methods, the inspection rules, and the marking, packaging, transport and storage. It applies to household DME cookers fed by the gas defined in GB 25035 whose nominal heat input per burner is not more than 5.23 kW; it does not apply to cookers used aboard moving vehicles or vessels, nor to combined gas and electric cookers. Large parts of the requirements are compulsory rather than recommended - among them the provisions on the gas circuit, the burners, the flame supervision device, the ignition, the electrical safety and the whole of the inspection rules and marking clauses, together with Tables 1, 2 and 4. The appliance must satisfy the general safety requirements for gas burning appliances of GB 16914, and an informative annex maps this standard's terms onto the basic requirements of that one. The materials clauses draw on the cable standards GB/T 5013.4 and GB/T 5023.3 and on the coated glass and ceramic panel specifications CJ/T 157 and CJ/T 305. Issued on 31 December 2012 and in force since 1 December 2013, it is a first edition, proposed by the Ministry of Housing and Urban-Rural Development.
This standard specifies the household gas stoves dimethyl ether (hereinafter referred to as gas stoves) and the classification models, requirements, test methods, inspection rules, standard Knowledge, packaging, transport and storage. This standard applies to GB 25035 DME predetermined gas source, a single burner is not greater than the nominal heat of household 5.23kW DME gas stove. This standard is not used for a gas stove in a movement of transport vehicles. This standard does not apply to gas-electric stove dual.
2 Normative references
The following documents for the application of this document is essential. For dated references, only applies to the version dated paper Pieces. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 191 Packaging Pictorial signs
GB/T 1019-2008 household and similar electrical packaging General
GB/T 5013.4 rated voltage of 450/750V rubber insulated cables and Part 4. Cords and flexible cables
GB/T 5023.3 rated voltage of 450/750V and below PVC insulated cables - Part 3. fixed wiring sheathed cable
GB/T 7306 (all parts) 55 ° pipe thread seal
GB/T 7307 55 ° non-sealing pipe thread
GB 16410-2007 domestic gas
GB/T 16411-2008 domestic gas appliances General Test Method
GB 16914-2012 Safety requirements for gas burning appliances
GB 25035 town gas with dimethyl ether CJ/T 157-2002 domestic gas with a coating glass panel CJ/T 305-2009 ceramic panel domestic gas
3 Terms and Definitions
The following terms and definitions apply to this document.
3.1 Rated thermal load ratedheatinput Rated heat flux nominalheatflowrate At a nominal gas pressure, the reference gas appliance using heat released per unit time. [CJ/T 3085-1999, the definition 7.2.15]
4 Flame Flame uniform homogeneity
Tempering No tempering 5 6 combustion noise is no greater than 65dB (A) 7 flame noise is not greater than 85dB (A) 8 dry flue gas carbon monoxide concentration (air excess coefficient alpha = 1, the volume percent) not greater than 0.05%
9 smoke no smoke
Huang Yan 10 contacts the contact electrode often not Huang Yan When using a large pot 11, combustion stability No flame, no temper
5.4.4 Temperature Rise Temperature should not exceed the value shown in Table 2. Table
2 Maximum normal temperature unit Kelvin No. rise site The hand operating portion to be in contact.
--- metallic materials and metal materials coated with a layer
--- non-metallic materials 2 battery housing
4.1 Classification
4.1.1 divided by the number stove eye. monocular lesions, eye lesions, eye lesions and more.
4.1.2 The form of the structure is divided into. desktop, embedded.
4.2 Model - - - - Household stoves (JZ) DME gas (M) Custom number Example. 968 home dimethyl ether gas stove is expressed as. "JZM-968".
5.1 The basic design parameters
5.1.1 rated gas pressure gas stoves should be 2.0kPa.
5.1.2 gas stove AC power, single phase should not exceed the rated voltage of 250V.
5.1.3 In the highlands use gas stoves, the impact of altitude on actual heat load should be considered.
5.2.1 General requirements
5.2.1.1 gas stove parts should be safe, durable, damage and deformation occurs not affect the use in normal operation.
5.2.1.2 gas stove should be sufficient stability during normal use, should not have sliding and dumping phenomenon.
5.2.1.3 gas stove should be overturned overall configuration inclined 15 ° in any direction, parts should not fall.
5.2.1.4 packaging structure and a gas stove should be able to withstand the stacking storage and transportation, falling and vibrations.
5.2.1.5 gas stove structure asbestos timber should not be used.
5.2.1.6 eye lesions and eye lesions multi-burner stoves pot-shaped center distance should be sized.
5.2.1.7 binocular eye lesions and multiple lesions and eye lesions should have a tip end of the pot holder applied to at least, should take pot stable in normal operation, might Hinder use.
5.2.1.8 gas stove should be provided for each burner flame failure protection devices.
5.2.1.9 gas stove burners should be set not less than two independent gas valve, shown in Figure 1, FIG. Description. 1
--- gas inlet; A valve 2
--- main burner. NOTE. Valve A and valve B are two independent functions. 1 a schematic view of a gas passage in series in FIG. Description. 1
--- gas inlet; 2
--- A main burner; 4
--- B main burner; 5
5.2.2 Structure Parts
5.2.2.1 when using and cleaning hands may touch parts has an end portion should be smooth.
5.2.2.2 gas stove connected parts should use standard fasteners, should be solid and reliable connection for easy removal.
5.2.2.3 parts cleaning, overhaul, using common tools should be easily removable.
a) should be easy to observe the state of combustion;
b) staking portion and connection portion should not affect the use of other defects;
c) fire hole machining accuracy, the influence of defects in the combustion or should not be modified;
d) casting defects should not affect the appearance and use;
e) from the head as two or more burners, the position of each other should be accurate; The mutual positions of the other related components
f) and the nozzle, an electrical ignition device, security device, etc. should be accurate, should not be moved during use or Off;
g) a flame should not overheat or damage to independent portion;
h) should be easy to clean and detachably;
i) the nozzle orifice outlet to the burner fire, the material used for all components, press tempering resistance test burner, the burner should not affect Deformation properties;
j) the nozzle should be easily removed using a general tool, mounted;
k) provided in the nozzle should be easily clogged foreign matter outside the dust position or easily be blocked, easy cleaning of the nozzle.
5.2.3 AC power for the ignition device of the gas stove structure
5.2.3.1 gas stove housing should be designed to use the tools necessary to open the structure and make it sufficient to accidental contact with live parts Protection.
5.2.3.2 power cord should be connected to a Y-gas stove.
5.2.3.3 power cord should meet the requirements GB/T 5023.3 or GB/T 5013.4 is.
5.2.3.4 clamping means of earthing terminals shall be adequately secured to prevent accidental loosening. If the cord from slipping out of the fixing device, the carrier should lead Be tightened before the grounding wire. A ground terminal and a ground terminal of the power cord plug
5.2.3.5 interior of the gas stove should be permanent signs.
5.2.3.6 direct AC power ignition device should be clearly permanent identification.
5.3.1 General Requirements material
5.3.1.1 should be able to withstand temperatures of normal use.
5.3.1.2 DME contacting material should be compatible with properties of DME.
5.3.1.3 metal member (except corrosion-resistant material) should plating, paint, enamel, or other suitable corrosion protection surface treatment.
5.3.1.4 material should be consistent with existing national standards. After the test material, shall meet the following requirements.
a) heat resistance. should not affect the use of the deformation;
b) Corrosion Resistance. The surface should be free from corrosion, the coating should be free of bubbles and the film, peeling and rusting;
c) steel ball impact resistance properties of enamel. enamel without shedding phenomenon;
d) Oil resistance. no deformation, does not affect.
5.3.2 Sealing material
5.3.2.1 rate of mass change after use for packing washers, gaskets, etc., the resistance test DME performance should be between ± 10%, but not Should soften the impact and embrittlement use.
5.3.2.2 rate of mass change after cock Lubricants resistance test was DME performance, at 20 °C when less than 10%, should be at 4 °C Less than 25%.
5.3.3 Burner
5.3.3.1 burner flame hole area should be greater than a melting point of 700 °C material.
5.3.3.2 wall thickness and surface treatment should meet the following requirements. Wall thickness
a) of the cast product of not less than 3mm, it should not have obvious casting defects such as porosity; Wall thickness
b) die cast product of not less than 1.5mm, should not affect the use of the defect;
c) a wall thickness of not less than
0.3 mm stainless steel products;
d) hot dip aluminizing steel products wall thickness of not less than
0.3 mm;
e) ordinary steel products, steel wall thickness not less than 0.5mm, and the surface for anti-corrosion treatment. At the enamel surface When Li, ball impact test should be done, there should be no enamel off;
f) the thickness of copper and copper alloy products should never be less than 1mm.
5.3.3.3 nozzle material deg.] C melting point greater than 500 should be used.
5.3.3.4 nozzle holder than 350 °C melting point materials should be used.
5.3.4 conductive material Use of conductive material copper, copper alloy or an equivalent or electrical properties, thermal stability material, mechanically stable properties, wherein the means for The need for flexibility in the location and other member materials, when not so limited risk does not occur.
5.3.5 Gas pipe Gas m.p. than 350 °C catheter material should be used.
5.4 Performance
5.4.1 airtightness Tightness of gas stoves should meet the following requirements.
a) from the gas inlet to the gas valve at a pressure of 4.2kPa, leakage of not more than 0.07L/h;
b) the automatic control valve in the pressure 4.2kPa, leakage of not more than 0.55L/h;
c) igniting the burner at
1.5 times the rated pressure, the fire-hole burner gas from the gas inlet to no leakage.
5.4.2 heat load The thermal load of the gas stove should meet the following requirements.
a) each burner heat load variation and conversion Found nominal heat should be within ± 10%;
b) The conversion Found single burner heat load Found conversion ratio of the sum of the thermal load of not less than 85%;
c) two above and two should be a main fire gas stove, the thermal load is actually measured conversion of not less than 3.5kW.
5.4.3 combustion conditions Gas stove combustion conditions should meet the requirements of Table 1. Table
1 Requirements combustion conditions No. Item Requirements 4s ignition flame in the transmission 1, no deflagration No 2 from the flame from the flame
6.1.1 Laboratory conditions According to the provisions in
6.1 of GB 16410-2007.
6.1.2 Test System
6.1.2.1 During the test, air pressure fluctuations should be less than 10Pa.
6.1.2.2 stopped when the gas stove, or the static pressure should be less than
1.25 times the gas supply pressure is equal to the runtime.
6.1.3 The test gas
6.1.3.1 Gas test species Various combustion test conditions should be used with gas GB 25035 meet the requirements of dimethyl ether gas, code-named "M".
6.1.3.2 test gas supply pressure Table
5 Test with the gas supply pressure. Table 5 test gas supply pressure is measured in pascal Code test gas pressure 1 (maximum test pressure) 3000 2 (rated gas pressure) 2000 3 (minimum test pressure) 1000
6.1.3.3 test gas condition code Test conditions for gas code represented by. Test code Type of gas - the gas supply pressure test code. Example. M-2 represents a gas DME - rated gas pressure.
6.1.4 The main test instrument Test instrument as specified in Table 6, the correction performed prior to the test instrument to deal with. Table
6 Main test instrumentation use (Pilot projects) Instrument name specification Accuracy or smallest scale range Room temperature measurement and gas thermometer 0 °C ~ 50 °C gas temperature of
0.5 deg.] C; rt 1 °C Atmospheric pressure gauge for measuring pressure 81kPa ~ 107kPa 0.1kPa Gas pressure measuring gauge 0Pa ~ 5000Pa 10Pa Time measuring stopwatch - 0.1s Determination of the dry gas flow gas flow - 0.1L Determination of the gas leak tightness test - - Noise measuring sound level 40dB ~ 120dB 1dB Gas chromatography assay components - - Determination of Carbon Monoxide CO tester 0 0.001% to 0.2% Determination of carbon dioxide tester 0 to 15% 0.01% Oxygen content sensing oxygen tester 0 to 21% 0.01% Temperature thermometer 0 °C ~ 100 °C 0.2 °C Measuring the surface temperature of the thermometer, a thermocouple 0 °C ~ 300 °C 2 °C Quality measuring instrument 0kg ~ 15kg 5g Leakage current measurement Ammeter, voltmeter, leakage current measurement Tester - - Electrical strength measuring electrical strength tester - - Grounding resistance meter measuring earth resistance - -
6.1.5 Test Equipment Test equipment to perform as specified in Table 7. Table
7 Test Equipment use (Pilot projects) Note the name of the type of test equipment Determining the thermal load of gas consumption measuring means Gas regulator, the dry gas flow meter, hygrometer, Thermometer, pressure gauge, measured with a three-way pressure Gas passage tightness test gas leak tightness testing device, the test fire burner - Durability Test Gas valve Endurance Test - - Ignition control means Endurance Test - - Safety Devices Endurance Test - - Solenoid valve means durability test - - Heat resistance test temperature structural components of the apparatus room thermostat ~ 750 °C Vibration test Vibration test Vibration test stand apparatus Vibration frequency of 10Hz, the whole vibration 5mm web down, left and right
6.1.6 gas stove test status Gas stove should be required to install and test the state of use, in addition to the various tests specified in the individual performance, it should meet the following basic Claim.
a) the amount of air required for burner, at rated pressure should be adjusted to the optimum state of the combustion flame, and then the damper is fixed, the Should not be transferred when the shutter performance test;
b) gas stove according to Table
8 Selected aluminum pan (lower limit pan) and heating water. Table 8 test gas stove pan and heated water Found thermal load / kW Pot size/mm Diameter pan pot wall thickness radius height Water heating/kg 1.40 180 0.6 ± 0.1 1.72 200 0.65 ± 0.1 2.08 220 0.65 ± ...
20 The valve housing 3 a 50 4 electric ignition device housing a
50 Gas stove side, rear wall wood, wood gas stove following table surface.
--- When using pot limit
--- When using large pot Internal wiring and external wiring, power cord comprises a rubber or PVC insulating surface.
--- sign with T-
--- without logo T- T-
25 When a statement when providing a temperature information, in accordance with (T-25) requirements.
5.4.5 thermal shock There should be no rupture gas stove panel of non-metallic thermal shock.
5.4.6 gravitational impact resistance There should be no rupture in the gas cooker gravitational impact resistance non-metallic panel.
5.4.7 safety device
5.4.7.1 Safety Devices should be met.
a) the valve opening time is less than 15s;
b) the valve closing time is less than 60s.
5.4.7.2 oil overheating control means should be met. The maximum temperature of the oil should not exceed 300 °C.
5.4.8 electric ignition device 10 ignition operation of the ignition time should be more than 8, not two consecutive failures, without deflagration.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 23 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 191Graphical symbols marking for handling and storage of packages
- GB 16410-2007Domestic gas cooking appliances
- GB/T 16411-2008Universal test methods of gas burning appliances for domestic use
- GB 16914-2012General safety technique requirements of gas burning appliances
GB/T 1019-2008 · GB/T 5013.4 · GB/T 5023.3 · GB/T 7306 · GB/T 7307 · GB 25035
Similar standards
GB 16410|GB 16914|GB 25035|GB/T 16411|CJ/T 157|CJ/T 305
How to Buy GB 29410-2012
- 1Add to cart. Click the "Buy GB 29410-2012" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 191-2025 — Graphical symbols marking for handling and storage of packages
GB/T 1910-2015 — Newsprint
GB/T 19100-2003 — Terminology work--Establishment of concept system
Secure payment via Stripe
Payments accepted
GB 29410-2012