HJ 2501-2010Technical requirement for environmental labeling products. Electrical wire and cable (English PDF)
环境标志产品技术要求 电线电缆
This is a limited preview
Buy now to download the full PDF (4 pages)
Need quotation for your management?
Get a formal quotation for HJ 2501-2010 in 30 minutes.
Issued by
Ministry of Ecology and Environment
Level / Type
National · Mandatory
Issue date
December 22, 2010
Implementation date
February 1, 2011
Scope
HJ 2501-2010 is the English-translated version of 环境标志产品技术要求 电线电缆.
HJ 2501-2010 — This standard specifies the terms and definitions, basic requirements, technical content and test methods for wire and cable environmental labeling products. This standard applies to all types of wire and cable products.
Found what you need?
Document preview — HJ 2501-2010
National Standard of the People's Republic of China
Issued by: Ministry of Ecology and Environment
Contents
- Foreword
- 1 Scope of application
- 2 Normative references
- 3 Terms and definitions
- 3.1 Wire and cable wire and cable
- 3.2 Halogen free halogen free
- 3.3 Low smoke low smoke
- 4 Basic requirements
- 5 Technical content
- 5.1 Requirements for toxic and hazardous substances in products
- 5.2 Halogen free requirements for the product
- 5.3 Low smoke requirements for the product
- 5.4 Toxicity requirements of the product
- 5.5 Product's combustion characteristics requirements
- 6 Test methods
Foreword
In order to implement the Environmental Protection Law of the People's Republic of China, guide wire and cable to protect the environment during design, production process and use.
To protect human health, this standard has been formulated.
This standard specifies the requirements for harmful substances, halogen-free, low-smoke, toxicity, and combustion of wires and cables.
This standard is the first release.
This standard applies to China Environmental Labeling Product Certification.
This standard was formulated by the Science and Technology Standards Department of the Ministry of Environmental Protection.
This standard is mainly drafted by. Environmental Development Center of the Ministry of Environmental Protection, National Wire and Cable Quality Supervision and Inspection Center, Jiangsu Middle Coal Cable Co., Ltd., Wuxi Jiangnan Cable Co., Ltd., Qingdao Han Cable Co., Ltd., Tianjin Plastic Cable Group Co., Ltd.
Company, Ningbo Ball Crown Cable Manufacturing Co., Ltd., Zhongyong Cable Electric Group Co., Ltd., Shanghai Sirui Polymer Technology Co., Ltd.
Shandong Luqiang Cable (Group) Co., Ltd., Xingle Group Co., Ltd.
This standard was approved by the Ministry of Environmental Protection on December 22, 2010.
This standard has been implemented since February 1, 2011.
This standard is explained by the Ministry of Environmental Protection.
Environmental Labeling Products Technical Requirements Wire and Cable
1 Scope of application
This standard specifies the terms and definitions, basic requirements, technical content and test methods for wire and cable environmental labeling products.
This standard applies to all types of wire and cable products.
2 Normative references
The contents of this standard refer to the terms in the following documents. For undated references, the valid version applies to this standard.
GB/T 12706.1-2008 rated voltage 1kV (Um=1.2kV) to 35kV (Um=40.5kV) extruded insulated power cable and Annex Part 1. Rated voltages 1kV (Um=1.2kV) and 3kV (Um=3.6kV) cables GB/T 17650.1-1998 Test methods for gases emitted from burning of cables or cables - Part 1 Measure GB/T 17650.2-1998 Test methods for gases emitted from burning of cables or cables - Part 2. Measuring pH Value and conductivity to determine the acidity of the gas GB/T 17651.2-1998.Determination of the density of smoke burning in certain conditions - Part 2. Test procedures and requirements GB/T 18380.12-2008 Burning tests for cables and cables under fire conditions - Part 12. Single insulated wire and cable flames Vertical spread combustion method 1kW premixed flame test method GB/T 18380.22-2008 Burning tests for cables and cables under fire conditions - Part 22. Single insulated wire and cable fire Flame vertical propagation combustion method diffusion type flame test method GB/T 19666-2005 General rules for fire-retardant and fire-resistant wires and cables GB/T 20285-2006 Material toxicity classification SJ/T 11365-2006 Methods for the detection of toxic and hazardous substances in electronic information products
3 Terms and definitions
The following terms and definitions apply to this standard.
3.1 Wire and cable wire and cable
A wire product used to transmit electrical energy or communication signals. Usually a collection of. one or more lines Cores, as well as cladding, insulating, total protective and outer sheaths that they may each have.
3.2 Halogen free halogen free
Wire and cable are halogen-free and the combustion products are less corrosive. (GB/T 19666-2005)
3.3 Low smoke low smoke
When the wire and cable are burned, less smoke is generated, that is, the light transmittance (visibility) is high. (GB/T 19666-2005)
4 Basic requirements
4.1 Product quality should meet the requirements of the corresponding product quality standards.
4.2 Pollutant emissions from product manufacturing enterprises shall comply with the requirements of national or local pollutant discharge standards.
4.3 Product manufacturers should strengthen clean production in the production process.
5 Technical content
5.1 Requirements for toxic and hazardous substances in products
5.1.1 Asbestos fibers shall not be included in the filler material used in the product.
5.1.2 The limits for toxic and hazardous substances in non-metallic materials (including paints for painted steel strips) used in products shall comply with the requirements of Table 1.
Table 1 Limits of toxic and hazardous substances in products. mg/kg
Species limit
Lead (Pb) <=1000
Mercury (Hg) <=1000
Separate (Cd) <=100
Hexavalent chromium (Cr 6 ) <=1000 Polybrominated biphenyl (PBB) <=1000 Polybrominated diphenyl ethers (PBDEs, excluding decabromodiphenyl ether) <=1000
5.2 Halogen free requirements for the product
5.2.1 Acid gas content
The bromine and chlorine content (expressed as HCl) must not exceed 0.5%.
5.2.2 Fluorine content
The fluorine content should not exceed 0.1%.
5.2.3 PH and conductivity
5.2.3.1 The gas pH of the product when burning shall not be less than 4.3.
5.2.3.2 The gas conductivity of the product during combustion shall not exceed 10 µS/mm.
5.3 Low smoke requirements for the product
When the product is burned to produce flue gas, the minimum light transmittance of the flue gas shall not be less than 60%.
5.4 Toxicity requirements of the product
When the product is burned to produce flue gas, the smoke toxicity should meet the requirements of Table 2.
Table 2 Product smoke toxicity requirements
Project Requirements Note 1 no anesthesia in the anesthetized experimental mice during the 30min exposure period (including within 1 hour after exposure) Immune experimental mice recovered their average body weight 3 days after exposure
Note 1. When the material combustion smoke concentration is greater than or equal to 12.4mg/L
5.5 Product's combustion characteristics requirements
The vertical burning performance of a single wire and cable shall be in the range of 50mm ~ 540mm at the lower edge of the upper clamp when the burnt portion is burned.
within.
6 Test methods
6.1 The technical content of 5.1.2 is tested in accordance with the method specified in SJ/T 11365-2006.
6.2 The technical content 5.2.1 is tested in accordance with the method specified in GB/T 17650.1-1998.
6.3 Technical content The detection of 5.2.2 shall be carried out in accordance with the method specified in GB/T 12706.1-2008.
6.4 Technical content The detection of 5.2.3 is carried out in accordance with the method specified in GB/T 17650.2-1998.
6.5 Technical content 5.3 The test shall be carried out in accordance with the method specified in GB/T 17651.2-1998.
6.6 The technical content of 5.4 is tested in accordance with the method specified in GB/T 20285-2006.
6.7 The technical content 5.5 shall be tested in accordance with the methods specified in GB/T 18380.12-2008 or GB/T 18380.22-2008.
6.8 Other indicators in the technical content are verified by document review combined with on-site inspection.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 4 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 12706.1-2008Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um=1.2 kV) up to 35 kV (Um=40.5 kV) - Part 1: Cables for rated voltage of 1 kV (Um=1.2 kV) and 3 kV (Um=3.6 kV)
- GB/T 17650.1-1998Test on gases evolved during combustion of materials from cables or optical fiber cables - Part 1: Determination of the halogen acid gas content
- GB/T 17650.2-1998Test on gases evolved during combustion of materials from cables or optical fiber cables - Part 2: Determination of acidity (by pH measurement) and conductivity
- GB/T 17651.2-1998Measurement of smoke density of cables or optical fiber cables burning under defined conditions - Part 2: Test procedure and requirements
- GB/T 18380.12-2008Tests on electric and optical fibre cables under fire conditions—Part 12:Test for vertical flame propagation for a single insulated wire or cable—Procedure for 1 kW pre-mixed flame
- GB/T 18380.22-2008Tests on electric and optical fibre cables under fire conditions -- Part 22: Test for vertical flame propagation for a single small insulated wire or cable -- Procedure for diffusion flame
How to Download HJ 2501-2010
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 18380.12-2008 — Test on electric and optical fibre cables under fire conditions -- Part 12: Test for vertical flame propagation for a single insulated wire or cable -- Procedure for 1kW pre-mixed flame
GB/T 18380.22-2008 — Tests on electric and optical fibre cables under fire conditions -- Part 22: Test for vertical flame propagation for a single small insulated wire or cable -- Procedure for diffusion flame
GB/T 20285-2006 — Toxic classification of fire effluents hazard for materials
Secure payment via Stripe
Payments accepted
HJ 2501-2010
$85.00