GB/T 14864-2013 is the English-translated version of 实心聚乙烯绝缘柔软射频电缆.
GB/T 14864-2013 is the Chinese standard "Solid-polyethene insulated flexible radio-frequency cables". Its scope clause reads: This standard specifies the soft solid polyethylene insulated RF cable product classifications, requirements, test methods, quality assessment and signs, packaging, Transport and storage.
This standard applies to radio communications and electronic devices employing similar techniques used in soft solid polyethylene insulated RF cable. It was issued on 2013-12-17.
Found what you need?
Document preview — GB/T 14864-2013
National Standard of the People's Republic of China
- ICS
- 33.120.10
- Classification
- L 26
- Replacing
- GB/T 14864-1993
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Introduction
- 1 Scope
- 2 Normative references
- 3 Product Category
- 3.1 Part
- 3.2 Series and Title
- 3.3 Schematic
- 3.4 Product marking
- 3.5 project uses data
- 4 4 technical requirements and test methods
- 4.1 cable construction and materials
- 4.2 Electrical properties
- 4.3 Environmental and mechanical properties
- 4.5 mark
- 4.6 length
- 5.1 General
- 5.2 Inspection classification
- 5.3 factory inspection
- 5.4 Type inspection
- 6 packaging, labeling, transportation and storage
- 6.1 Packaging
- 6.2 mark
- Appendix A (informative) project uses data
- Appendix B (normative) LSZH polyolefin sheath material 34 key performance indicators
- Annex C (normative) Off voltage test halo
- Annex D (informative) Identification of the type test sample extended grouping
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
This standard replaces GB/T 14864-1993 "Solid PE insulated radio frequency cable."
This standard compared with GB/T 14864-1993, the main technical changes are as follows.
--- Standard name changed to "soft solid polyethylene insulated RF cable";
--- Increasing the type designation and code meaning description (see 3.1);
--- According to the practical application of the product, increasing the polyethylene sheath and LSZH polyolefin sheathed product specifications (see Table 3 ~ table 5);
--- Increased combustion performance requirements and test methods for flame retardant cable (see 4.4);
--- Eccentricity increased media requirements (see Section 4.1.3);
--- The engineering data dimensional stability as the content requirements (see 4.3.6);
--- The project uses data adjusted by the content of the standard text to Appendix A;
--- "Length measurement error should not exceed ± 10%" to "length measurement error of ± 0.5%" (see 46, 1993. Version 4.4.);
--- Increase in Appendix B "halogen flame retardant polyolefin sheath material key performance indicators";
--- Increase in Appendix C "voltage test destroy Halo."
Please note that some of the content of this document may involve patents. Release mechanism of the present document does not assume responsibility for the identification of these patents.
The standard proposed by the Ministry of Industry and Information Technology of the People's Republic of China.
1 Scope
This standard specifies the soft solid polyethylene insulated RF cable product classifications, requirements, test methods, quality assessment and signs, packaging, Transport and storage.
This standard applies to radio communications and electronic devices employing similar techniques used in soft solid polyethylene insulated RF cable.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 2951.11-2008 cable and the cable Common test methods for insulating sheathing materials - Part 11: Common test methods --- Measurement of thickness and overall dimensions --- mechanical tests (IEC 60811-1:2001, IDT)
GB/T 3953-2009 electrician round copper wire
GB/T 4909.2-2009 Test methods for bare wires - Part 2: Measure
GB/T 4910-2009 tinned round copper wire
GB/T 8170 repair value expressed about the rules and limit values and judgment
GB/T 8815-2008 with a soft PVC wire and cable
GB/T 15065-2009 black polyethylene plastic wire and cable
Gases evolved during combustion of GB/T 17650.2-1998 materials from cables - Test methods - Part 2: Measurement pH and conductivity to determine the gas acidity (idt IEC 60754-2:1991, AmendmentNo.1.1997)
GB/T 17651.2-1998 of cables burning under defined conditions Measurement of smoke density - Part 2: Test procedure and requirements (Idt IEC 61034-2:1997)
GB/T 17737.1-2000 frequency cables - Part 1: Generic specification - General, definitions, requirements and test methods (idt IEC 61196-1:1995)
GB/T 17737.1-2013 Coaxial communication cables - Part 1: Generic specification - General, definitions and requirements (IEC 61196-1:2005, IDT)
GB/T 18380.12-2008 burning test and optical fiber cables under fire conditions - Part 12. single insulated wire and cable fire Test 1kW pre-mixed flame spread vertical flame test methods (IEC 60332-1-2:2004, IDT)
JB/T 3135-2011 silver-plated soft round copper wire
YD/T 760-1995 Local telecommunication cables with polyolefin insulation materials
IEC 61196-1-102:2005 Coaxial communication cables - Part 1-102. Electrical test methods - Insulation resistance test cable media (Coaxialcommunicationcables-Part 1-102. Electricaltestmethods-Testforinsulationresistanceof cabledielectric)
IEC 61196-1-103:2005 Coaxial communication cables - Part 1-103. Electrical test methods for electric cables - Capacitance test (Coaxial communicationcables-Part 1-103. Electricaltestmethods-Testforcapacitanceofcable)
IEC 61196-1-105:2005 Coaxial communication cables - Part 1-105. Electrical test methods for cable dielectric withstanding voltage test (Coaxialcommunicationcables-Part 1-105. Electricaltestmethods-Testforwithstandvoltageof cabledielectric)
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 36 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 2951.11-2008Common test methods for insulating and sheathing materials of electric and optical cables -- Part 11: Methods for general application -- Measurement of thickness and overall dimensions -- Tests for determining the mechanical properties
- GB/T 3953-2009Round copper wire for electrical purposes
- GB/T 4909.2-2009Test methods for bare wires - Part 2: Measurement of dimensions
- GB/T 4910-2009Tinned round copper wire
- GB/T 8170Rules of rounding off for numerical values & expression and judgement of limiting values
- GB/T 8815-2008Plasticized polyvinyl chloride (PVC) compounds for wire and cable
IEC 61196-1-102:2005 · IEC 61196-1-103:2005 · IEC 61196-1-105:2005
Similar standards
Editions of GB/T 14864
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 14864-2013 | Solid-polyethene insulated flexible radio-frequency cables | current edition | Current |
| GB/T 14864-1993 | Solid-polyethene insulated flexible radio-frequency cables | previous edition | Superseded |
This page sells the current edition, GB/T 14864-2013. Earlier editions are listed for reference only.
How to Download GB/T 14864-2013
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 15065-2009 — Black polyethylene compounds for wire and cable
GB/T 17737.1-2013 — Coaxial communication cables -- Part 1: Generic specification -- General, definitions and requirements
GB/T 18380.12-2008 — Test on electric and optical fibre cables under fire conditions -- Part 12: Test for vertical flame propagation for a single insulated wire or cable -- Procedure for 1kW pre-mixed flame
Secure payment via Stripe
Payments accepted
GB/T 14864-2013
$500.00