Scope
GB/T 18890.2-2015 is the English-translated version of 额定电压220kV(Um=252 kV)交联聚乙烯绝缘电力电缆及其附件 第2部分:电缆.
GB/T 18890.2-2015 is the Chinese standard "Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 220 kV (Um = 252 kV) - Part 2: Power cables".
Its scope clause reads: This Part of GB/T 18890 specifies the model, naming, technical requirements, test and inspection rules, packaging, transportation and storage of fixedly installed power cables with cross-linked polyethylene insulation for rated voltage of 220 kV (Um = 252 kV).
This Part applies to single-core power cables used under normal installation and operating conditions; it is not applicable to the cables used under special conditions, such as submarine power cables.
Its clauses include terms and definitions; use characteristics; product naming; technical requirements; marking of finished power cables; test requirements; acceptance rules; packaging, transportation and storage.
It was issued by the General Administration of Quality Supervision, Inspection and Quarantine on OCTOBER 09, 2015 and took effect on MAY 01, 2016.
Found what you need?
Document preview — GB/T 18890.2-2015
National Standard of the People's Republic of China
- ICS
- 29.060.20
- Classification
- K 13
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- 1 Scope6
- 2 Normative references6
- 3 Terms and definitions8
- 4 Use characteristics9
- 5 Product naming10
- 6 Technical requirements12
- 7 Marking of finished power cables19
- 8 Test requirements19
- 9 Acceptance rules23
- 10 Packaging, transportation and storage23
- Appendix A25
- Appendix B27
- Bibliography28
Foreword
GB/T 18890 "Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 220 kV (Um = 252 kV)" is divided into three parts.
- Part 1. Test methods and requirements;
- Part 2. Power cables;
- Part 3. Accessories.
This Part is Part 2 of GB/T 18890.
This Part is drafted in accordance with the rules given in GB/T 1.1-2009.
This Part replaces GB/Z 18890.2-2002 "Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 220 kV (Um = 252 kV) - Part 2:
Power cables with cross-linked polyethylene insulation for rated voltage of 220 kV (Um = 252 kV)". Compared with GB/Z 18890.2-2002, the main technical changes of this Part are as follows.
- The nature of the standard is revised FROM technical guidance document TO recommended standard;
- The standard name is revised FROM "Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 220 kV (Um = 252 kV) - Part 2. Power cables with cross-linked polyethylene insulation for rated voltage of 220 kV (Um = 252 kV)" TO "Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 220 kV (Um = 252 kV)";
- ADD the definition of metal-plastic laminated sheathes (see 3.2);
- ADD use characteristics and power cable ampacity (see 4.3);
- ADD the code, model and name of metal-plastic laminated sheathes (see 5.1, Table 1);
- MODIFY the note of corrugated aluminum sheathes (see Table 1, note of 5.1 in 2002 edition);
- ADD the requirements and labeling methods for copper wire shielding (see 5.3);
- DELETE Chapter 6 "Materials" in 2002 edition, its content is included in the relevant chapters of technical requirements;
1 Scope
This Part of GB/T 18890 specifies the model, naming, technical requirements, test and inspection rules, packaging, transportation and storage of fixedly installed power cables with cross-linked polyethylene insulation for rated voltage of 220 kV (Um = 252 kV).
This Part applies to single-core power cables used under normal installation and operating conditions; it is not applicable to the cables used under special conditions, such as submarine power cables.
2 Normative references
The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) are applicable to this document.
GB/T 494-2010 Asphalt used in roofing
GB/T 2951.11-2008 Common test methods for insulating and sheathing materials of electric and optical cables - Part 11: Methods for general application - Measurement of thickness and overall dimensions - Tests for determining the mechanical properties
GB/T 2951.12-2008 Common test methods for insulating and sheathing materials of electric and optical cables - Part 12: Methods for general application - Thermal aging methods
GB/T 2951.14-2008 Common test methods for insulating and sheathing materials of electric and optical cables - Part 14: Common test methods - Low Temperature Test
GB/T 2951.21-2008 Common test methods for insulating and sheathing materials of electric and optical cables - Part 21: Methods specific to elastomeric compounds - Ozone resistance, hot set and mineral oil immersion tests
GB/T 2951.31-2008 Common test methods for insulating and sheathing materials of electric and optical cables - Part 31: Methods specific to PVC compounds - Pressure test at high temperature - Test for resistance to cracking
GB/T 2951.32-2008 Common test methods for insulating and sheathing materials of electric and optical cables - Part 32: Methods specific to PVC compounds - Loss of mass test - Thermal stability test
GB/T 2951.41-2008 Common test methods for insulating and sheathing materials of electric and optical cables - Part 41: Methods specific to polyethylene and polypropylene compounds - Resistance to environmental stress cracking - Measurement of the melt flow index - Carbon black
GB/T 3048.4-2007 Test methods for electrical properties of electric cables and wires - Part 4: Test of DC resistance of conductors
GB/T 3048.8-2007 Test methods for electrical properties of electric cables and wires - Part 8: AC voltage test
GB/T 3048.11-2007 Test methods for electrical properties of electric cables and wires - Part 11: Test for dielectric dissipation factor
GB/T 3048.12-2007 Test methods for electrical properties of electric cables and wires - Part 12: Partial discharge test
GB/T 3048.13-2007 Test methods for electrical properties of electric cables and wires - Part 13: Impulse voltage test
GB/T 3048.14-2007 Test methods for electrical properties of electric cables and wires - Part 14: DC voltage test
GB/T 3880.1-2012 Wrought aluminium and aluminium alloy plates, sheets and strips for general engineering - Part 1: Technical conditions of delivery
GB/T 3953 Round copper wire for electrical purposes
GB/T 3956 Conductors of insulated cables
GB/T 6995.3-2008 Markings for electric wires and cables - Part 3: Identifications of cables and wires
GB/T 18380.12-2008 Test on electric and optical fibre cables under fire conditions - Part 12: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1kW pre-mixed flame
GB/T 18890.1-2015 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 220 kV (Um = 252 kV) - Part 1: Test methods and requirements
GB/T 26011-2010 Lead alloy ingot for cable sheath bond
JB/T 5268.1-2011 Metal sheaths for cables - Part 1: General requirement
JB/T 8137 (all parts) Delivery drums for wires and cables
JB/T 10181.11-2014 Calculation of the current rating of electric cables - Part 1:
Current rating equations (100% load factor) and calculation of losses - Section 1. General
JB/T 10259 Waterblocking tape for electric cables and optical fiber cables
JB/T 10696.5-2007 Test methods for determining mechanical physical and chemical properties of electric cables and wires - Part 5: Corrosion spread test
JB/T 10696.6-2007 Test methods for determining mechanical physical and chemical properties of electric cables and wires - Part 6: Test for abrasion of oversheaths
YD/T 723-2007 (all parts) Laminated metal plastic strip for communication cable and optical fibre cable
IEC 60183 Guidance for the selection of high-voltage a.c. cable systems
3 Terms and definitions
The following terms and definitions and those defined in GB/T 18890.1-2015 apply to this document.
3.1 Approximate value
A kind of value that is neither guaranteed nor checked, for example, being used to calculate the value of other sizes.
3.2 Metal-plastic laminated sheath
Laminated sheathes of longitudinally-wrapped metal tapes or longitudinally-wrapped metal foils, having a bonding characteristic with power cable's outer sheathes.
YJQ02-Z Power cables with cross-linked polyethylene insulation lead sheath, PVC sheath and longitudinal waterblocking structure YJQ03-Z Power cables with cross-linked polyethylene insulation lead sheath, PE sheath and longitudinal waterblocking structure YJA03 Power cables with cross-linked polyethylene insulation metal-plastic laminated sheath and PE sheath YJA03-Z Power cables with cross-linked polyethylene insulation metal-plastic laminated sheath and longitudinal waterblocking structure
NOTE: […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 28 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 494-2010Asphalt used in roofing
- GB/T 2951.11-2008Common test methods for insulating and sheathing materials of electric and optical cables -- Part 11: Methods for general application -- Measurement of thickness and overall dimensions -- Tests for determining the mechanical properties
- GB/T 2951.12-2008Common test methods for insulating and sheathing materials of electric and optical cables -- Part 12: Methods for general application -- Thermal ageing methods
- GB/T 2951.14-2008Common test methods for insulating and sheathing materials of electric and optical cables -- Part 14: Methods for general application -- Test at low temperature
- GB/T 2951.21-2008Common test methods for insulating and sheathing materials of electric and optical cables -- Part 21: Methods specific to elastomeric compounds -- Ozone resistance, hot set and mineral oil immersion tests
- GB/T 2951.31-2008Common test methods for insulating and sheathing materials of electric and optical cables -- Part 31: Methods specific to PVC compounds -- Pressure test at high temperature -- Test for resistance to cracking
JB/T 8137 · YD/T 723-2007 · IEC 60183
Cited by
- GB/T 22577-2025Class 1E cables for nuclear power generating stations - General requirements
- GB/T 22381-2017Cable connections between gas-insulated metal-enclosed switchgear for rated voltages equal to and above 72.5 kV and fluid-filled and extruded insulation power cables -- Fluid-filled and dry type cable-terminations
- JB/T 13201-2017Medium and high voltage triple-layer co-extrusion catenary dry-cure crosslinking lines
- GB/T 22078.2-2008Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 500kV (Um=550kV) - Part2: Power cables with cross-linked polyethylene insulation for rated voltage of 500kV (Um=550kV)
Similar standards
How to Download GB/T 18890.2-2015
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 18380.12-2008 — Test on electric and optical fibre cables under fire conditions -- Part 12: Test for vertical flame propagation for a single insulated wire or cable -- Procedure for 1kW pre-mixed flame
GB/T 18890.1-2015 — Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 220 kV (Um=252 kV) -- Part 1: Test methods and requirements
GB/T 26011-2010 — Lead alloy for cable sheath bond
Secure payment via Stripe
Payments accepted
GB/T 18890.2-2015
$105.00