Valid

GB/T 18890.2-2015Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 220 kV (Um=252 kV) —Part 2: Power cables (English PDF)

额定电压220kV(Um=252 kV)交联聚乙烯绝缘电力电缆及其附件 第2部分:电缆

Preview PDF

This is a limited preview

Buy now to download the full PDF (28 pages)

Need quotation for your management?

Get a formal quotation for GB/T 18890.2-2015 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

October 9, 2015

Implementation date

May 1, 2016

Scope

GB/T 18890.2-2015 is the English-translated version of 额定电压220kV(Um=252 kV)交联聚乙烯绝缘电力电缆及其附件 第2部分:电缆.

GB/T 18890.2-2015 is the Chinese standard "Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 220 kV (Um = 252 kV) - Part 2: Power cables".

Its scope clause reads: This Part of GB/T 18890 specifies the model, naming, technical requirements, test and inspection rules, packaging, transportation and storage of fixedly installed power cables with cross-linked polyethylene insulation for rated voltage of 220 kV (Um = 252 kV).

This Part applies to single-core power cables used under normal installation and operating conditions; it is not applicable to the cables used under special conditions, such as submarine power cables.

Its clauses include terms and definitions; use characteristics; product naming; technical requirements; marking of finished power cables; test requirements; acceptance rules; packaging, transportation and storage.

It was issued by the General Administration of Quality Supervision, Inspection and Quarantine on OCTOBER 09, 2015 and took effect on MAY 01, 2016.

Found what you need?

Document preview — GB/T 18890.2-2015

National Standard of the People's Republic of China

ICS
29.060.20
Classification
K 13

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword3
  • 1 Scope6
  • 2 Normative references6
  • 3 Terms and definitions8
  • 4 Use characteristics9
  • 5 Product naming10
  • 6 Technical requirements12
  • 7 Marking of finished power cables19
  • 8 Test requirements19
  • 9 Acceptance rules23
  • 10 Packaging, transportation and storage23
  • Appendix A25
  • Appendix B27
  • Bibliography28

Foreword

GB/T 18890 "Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 220 kV (Um = 252 kV)" is divided into three parts.

- Part 1. Test methods and requirements;

- Part 2. Power cables;

- Part 3. Accessories.

This Part is Part 2 of GB/T 18890.

This Part is drafted in accordance with the rules given in GB/T 1.1-2009.

This Part replaces GB/Z 18890.2-2002 "Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 220 kV (Um = 252 kV) - Part 2:

Power cables with cross-linked polyethylene insulation for rated voltage of 220 kV (Um = 252 kV)". Compared with GB/Z 18890.2-2002, the main technical changes of this Part are as follows.

- The nature of the standard is revised FROM technical guidance document TO recommended standard;

- The standard name is revised FROM "Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 220 kV (Um = 252 kV) - Part 2. Power cables with cross-linked polyethylene insulation for rated voltage of 220 kV (Um = 252 kV)" TO "Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 220 kV (Um = 252 kV)";

- ADD the definition of metal-plastic laminated sheathes (see 3.2);

- ADD use characteristics and power cable ampacity (see 4.3);

- ADD the code, model and name of metal-plastic laminated sheathes (see 5.1, Table 1);

- MODIFY the note of corrugated aluminum sheathes (see Table 1, note of 5.1 in 2002 edition);

- ADD the requirements and labeling methods for copper wire shielding (see 5.3);

- DELETE Chapter 6 "Materials" in 2002 edition, its content is included in the relevant chapters of technical requirements;

1 Scope

This Part of GB/T 18890 specifies the model, naming, technical requirements, test and inspection rules, packaging, transportation and storage of fixedly installed power cables with cross-linked polyethylene insulation for rated voltage of 220 kV (Um = 252 kV).

This Part applies to single-core power cables used under normal installation and operating conditions; it is not applicable to the cables used under special conditions, such as submarine power cables.

2 Normative references

The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) are applicable to this document.

GB/T 494-2010 Asphalt used in roofing

GB/T 2951.11-2008 Common test methods for insulating and sheathing materials of electric and optical cables - Part 11: Methods for general application - Measurement of thickness and overall dimensions - Tests for determining the mechanical properties

GB/T 2951.12-2008 Common test methods for insulating and sheathing materials of electric and optical cables - Part 12: Methods for general application - Thermal aging methods

GB/T 2951.14-2008 Common test methods for insulating and sheathing materials of electric and optical cables - Part 14: Common test methods - Low Temperature Test

GB/T 2951.21-2008 Common test methods for insulating and sheathing materials of electric and optical cables - Part 21: Methods specific to elastomeric compounds - Ozone resistance, hot set and mineral oil immersion tests

GB/T 2951.31-2008 Common test methods for insulating and sheathing materials of electric and optical cables - Part 31: Methods specific to PVC compounds - Pressure test at high temperature - Test for resistance to cracking

GB/T 2951.32-2008 Common test methods for insulating and sheathing materials of electric and optical cables - Part 32: Methods specific to PVC compounds - Loss of mass test - Thermal stability test

GB/T 2951.41-2008 Common test methods for insulating and sheathing materials of electric and optical cables - Part 41: Methods specific to polyethylene and polypropylene compounds - Resistance to environmental stress cracking - Measurement of the melt flow index - Carbon black

GB/T 3048.4-2007 Test methods for electrical properties of electric cables and wires - Part 4: Test of DC resistance of conductors

GB/T 3048.8-2007 Test methods for electrical properties of electric cables and wires - Part 8: AC voltage test

GB/T 3048.11-2007 Test methods for electrical properties of electric cables and wires - Part 11: Test for dielectric dissipation factor

GB/T 3048.12-2007 Test methods for electrical properties of electric cables and wires - Part 12: Partial discharge test

GB/T 3048.13-2007 Test methods for electrical properties of electric cables and wires - Part 13: Impulse voltage test

GB/T 3048.14-2007 Test methods for electrical properties of electric cables and wires - Part 14: DC voltage test

GB/T 3880.1-2012 Wrought aluminium and aluminium alloy plates, sheets and strips for general engineering - Part 1: Technical conditions of delivery

GB/T 3953 Round copper wire for electrical purposes

GB/T 3956 Conductors of insulated cables

GB/T 6995.3-2008 Markings for electric wires and cables - Part 3: Identifications of cables and wires

GB/T 18380.12-2008 Test on electric and optical fibre cables under fire conditions - Part 12: Test for vertical flame propagation for a single insulated wire or cable - Procedure for 1kW pre-mixed flame

GB/T 18890.1-2015 Power cables with cross-linked polyethylene insulation and their accessories for rated voltage of 220 kV (Um = 252 kV) - Part 1: Test methods and requirements

GB/T 26011-2010 Lead alloy ingot for cable sheath bond

JB/T 5268.1-2011 Metal sheaths for cables - Part 1: General requirement

JB/T 8137 (all parts) Delivery drums for wires and cables

JB/T 10181.11-2014 Calculation of the current rating of electric cables - Part 1:

Current rating equations (100% load factor) and calculation of losses - Section 1. General

JB/T 10259 Waterblocking tape for electric cables and optical fiber cables

JB/T 10696.5-2007 Test methods for determining mechanical physical and chemical properties of electric cables and wires - Part 5: Corrosion spread test

JB/T 10696.6-2007 Test methods for determining mechanical physical and chemical properties of electric cables and wires - Part 6: Test for abrasion of oversheaths

YD/T 723-2007 (all parts) Laminated metal plastic strip for communication cable and optical fibre cable

IEC 60183 Guidance for the selection of high-voltage a.c. cable systems

3 Terms and definitions

The following terms and definitions and those defined in GB/T 18890.1-2015 apply to this document.

3.1 Approximate value

A kind of value that is neither guaranteed nor checked, for example, being used to calculate the value of other sizes.

3.2 Metal-plastic laminated sheath

Laminated sheathes of longitudinally-wrapped metal tapes or longitudinally-wrapped metal foils, having a bonding characteristic with power cable's outer sheathes.

YJQ02-Z Power cables with cross-linked polyethylene insulation lead sheath, PVC sheath and longitudinal waterblocking structure YJQ03-Z Power cables with cross-linked polyethylene insulation lead sheath, PE sheath and longitudinal waterblocking structure YJA03 Power cables with cross-linked polyethylene insulation metal-plastic laminated sheath and PE sheath YJA03-Z Power cables with cross-linked polyethylene insulation metal-plastic laminated sheath and longitudinal waterblocking structure

NOTE: […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 28 pages — is available in the English PDF.

Referenced standards

Normative references

JB/T 8137 · YD/T 723-2007 · IEC 60183

Similar standards

How to Download GB/T 18890.2-2015

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
28 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 18890.2-2015

$105.00