Scope
GB/T 4772.1-2025 (Dimensions and output series for rotating electrical machines - Part 1: Frame numbers 56 to 400 and flange numbers 55 to 1080) is available as an English-translated PDF.
GB/T 4772.1-2025 — This document applies to rotating motors for most industrial applications, with the following size and power ranges. - Foot-mounted. Shaft height.
56 mm ~ 400 mm; - Flange-mounted. Flange base circle diameter. 55 mm ~ 1080 mm. This document specifies the correspondence between mounting dimensions, shaft extension dimensions, output power ratings and frame numbers.
Found what you need?
Document preview — GB/T 4772.1-2025
National Standard of the People's Republic of China
- ICS
- 29.160.01
Issued by: Status Administration for Market Regulation
Contents
- Foreword...3
- Introduction...5
- 1 Scope...6
- 2 Normative references...6
- 3 Terms and definitions...7
- 4 Symbols...7
- 4.1 Dimensional symbols...7
- 4.2 Dimensional diagram...10
- 5 Motor dimension designation...12
- 5.1 Frame number...12
- 5.2 Flange number...12
- 5.3 Shaft extension...12
- 6 Terminal box location...12
- 6.1 Motors with foot...12
- 6.2 Motors without foot...13
- 7 Mounting dimensions and tolerances...13
- 7.1 Overview...13
- 7.2 Foot-mounted motors...13
- 7.3 Flange-mounted motors...15
- 8 Shaft end dimensions and tolerances...16
- 8.1 Shaft end dimensions...16
- 8.2 Parallelism of the shaft to the foot plane...17
- 8.3 Axis parallelism of keyway to shaft...18
- 8.4 Lateral runout of keyway...18
- 9 Test method...18
- 9.1 Overview...18
- 9.2 Shaft extension runout...19
- 9.3 Radial runout of the flange end to motor axis...19
- 9.4 End circular runout of the flange mounting surface to motor axis...20
- 9.5 Parallelism of shaft to foot plane...20
- 9.6 Parallelism of keyway to shaft axis...21
- 9.7 Keyway lateral displacement...21
- 10 Preferred rated output power...22
Foreword
This document was drafted in accordance with the provisions of GB/T 1.1-2020
"Directives for standardization - Part 1.Rules for the structure and drafting of
standardizing documents".
This document is Part 1 of GB/T 4772 "Dimensions and output series for rotating
electrical machines". The following parts of GB/T 4772 have been published.
- Part 1.Frame numbers 56 to 400 and flange numbers 55 to 1080;
- Part 2.Frame numbers 355 to 1000 and flange numbers 1180 to 2360;
- Part 3.Small built-in motors - Flange numbers BF10 to BF50.
This document replaces GB/T 4772.1-1999 "Dimensions and output series for rotating
electrical machines - Part 1.Frame numbers 56 to 400 and flange numbers 55 to 1080".
Compared to GB/T 4772.1-1999, in addition to structural adjustments and editorial
changes, the major technical changes are as follows.
- ADD the motor dimension symbols such as AC' and BC (see Chapter 4);
- CHANGE the motor dimension symbol description (see Chapter 5; Chapter 4 of
the 1999 edition);
- CHANGE the installation dimension tables for foot-mounted motors and flange-
mounted motors (see Tables 1 and 2; Tables 1 and 3 of the 1999 edition);
- CHANGE the tables of key, keyway, shaft dimensions, adding dimensions for D
values of 120 to 150 (see Table 3; Table 4 of the 1999 edition);
- CHANGE the shaft-to-foot parallelism (see 8.2; C4.1 of the 1999 edition);
- CHANGE the parallelism of the keyway to the shaft axis (see 8.3; C5.1 of the 1999
edition);
- CHANGE the lateral displacement of the keyway (see 8.4; C5.2 of the 1999
edition);
- CHANGE the shaft runout test method (see 9.2; C6.2 of the 1999 edition);
- ADD test methods for shaft parallelism to the foot plane, keyway parallelism to the
shaft axis, keyway lateral displacement (see 9.5, 9.6, 9.7);
- CHANGE the preferred rated output power table (see Table 6; Table 7 of the 1999
edition);
- ADD the relationship between frame number, shaft extension, rated power, flange
number (see Chapter 11).
This document identically adopts IEC 60072-1.2022 "Rotating electrical machines -
Dimensions and output series - Part 1.Frame number 56 to 400 and flange numbers 55
to 1080".
This document has been modified for the following minimal editorial purposes.
- To align with existing standards, CHANGE the standard title to "Dimensions and
output series for rotating electrical machines - Part 1.Frame numbers 56 to 400
and flame number 55 to 1080".
Please note that some content in this document may involve patents. The issuing
organization of this document assumes no responsibility for identifying patents.
This document was proposed by the China Electrical Equipment Industry Association.
This document shall be under the jurisdiction of the National Technical Committee for
Standardization of Rotating Electrical Machines (SAC/TC 26).
Drafting organizations of this document. Shanghai Motor System Energy Saving
Engineering Technology Research Center Co., Ltd., Jiangsu Dazhong Motor Co., Ltd.,
Jiamusi Motor Co., Ltd., Anhui Wannan Motor Co., Ltd., Hebei Motor Co., Ltd.,
Nanyang Explosion-Proof (Suzhou) Special Equipment Co., Ltd., Xi'an Xima Motor
Co., Ltd., Inmonda Motor (China) Co., Ltd., Jiangsu Xianda Explosion-Proof Co., Ltd.,
Hunan Liancheng Rail Equipment Co., Ltd., Jiangsu Yali Explosion-Proof Motor Co.,
Ltd., Xiangtan Motor Co., Ltd., Wuhan Autebi Motor Co., Ltd., Shanghai ABB Motor
Co., Ltd., Shanghai Representative Office of the International Copper Professionals
Association, Ningbo Anxin CNC Technology Co., Ltd., Foshan Demart Intelligent
Equipment Technology Co., Ltd., Jiangsu Youqu Electromechanical Technology Co.,
Ltd.
1 Scope
This document applies to rotating motors for most industrial applications, with the
following size and power ranges.
- Foot-mounted. Shaft height. 56 mm ~ 400 mm;
- Flange-mounted. Flange base circle diameter. 55 mm ~ 1080 mm.
This document specifies the correspondence between mounting dimensions, shaft
extension dimensions, output power ratings and frame numbers.
2 Normative references
The contents of the following documents, through normative references, constitute
essential provisions of this document. For dated references, only the version
corresponding to that date applies to this document. For undated references, the latest
version (including all amendments) applies to this document.
ISO 128-3.2022 Technical product documentation (TPD) - General principles of
representation - Part 3.Views, sections and cuts
Note. The referenced content in ISO 128-3.2022 does not technically differ from that in ISO
128-3.2020.
ISO 273 Fasteners - Clearance holes for bolts and screws
Note. GB/T 5277-1985 Fasteners - Clearance holes for bolts and screws (ISO 273.1979,
IDT)
ISO 286 (all parts) Geometrical product specifications (GPS) - ISO code system for
tolerances on linear sizes
Note. GB/T 1800 (all parts) Geometrical product specifications (GPS) - ISO code system
for tolerances on linear sizes
ISO 1101 Geometrical product specifications (GPS) - Geometrical tolerances -
Tolerances of form, orientation, location and run-out
Note. GB/T 1182-2018 Geometrical product specifications (GPS) - Geometrical tolerancing
- Tolerances of form, orientation, location and run-out (ISO 1101.2017, MOD)
ISO 2768-1 - General tolerances - Part 1.Tolerances for linear and angular
dimensions without individual tolerance indications
Note. GB/T 1804-2000 General tolerances - Tolerances for linear and angular dimensions
without individual tolerance indications (ISO 2768-1.1989, IDT)
3 Terms and definitions
This document does not require the use of defined terms and definitions.
ISO and IEC maintain terminology databases for standardization at the following
addresses.
4 Symbols
4.1 Dimensional symbols
The following specified symbols are illustrated using the dimension diagram in Figure
1 Mandatory dimensions are marked with an *.
*A. Distance between the axis of the anchor bolt holes (end view)
AA. Foot width (end view)
AB. Distance between the outer edges of the foot (end view)
AC. Maximum width of the motor (maximum outer dimensions, including the fan
housing; not including the terminal box and foot)
AC'. Maximum height of the motor (maximum outer dimensions)
AD. Distance from the vertical centerline of the motor to the edge of the terminal
box or other protruding component mounted on the side of the motor
*B. Distance between the axis of the anchor bolt holes (side view)
BA. Foot length (D end; side view)
5 Motor dimension designation
5.1 Frame number
Motors can be designated by frame number, which is defined as the distance from the
motor axis to the bottom of the foot (H dimension). The relationship between H
dimension and fixed dimensions (A, B, C, K) is shown in Table 1.
Recommended letter designations for frame number.
- S, short frame number;
- M, medium frame number;
- L, long frame number.
Table B.1 in Appendix B provides other recommended frame number letters.
Note. Frame numbers also apply to motors without feet.
5.2 Flange number
The flange number is defined as the base diameter M. Table 2 shows the dimensions of
M and its relationship to the fixed dimensions (N, P, R, S, T). The location of the holes
in the mounting flange is shown in Figure 1.
Recommended flange number letters.
- FF flange, with through holes;
- FT flange, with threaded holes.
5.3 Shaft extension
The shaft size designation is defined by the shaft extension diameter D. Table 3 shows
the dimensions of D and its relationship to related dimensions (e.g., E, key).
6 Terminal box location
6.1 Motors with foot
Viewed from the D-end of the motor, the terminal box should be located within an angle
of 10° from the motor's centerline to the right horizontal centerline, with its centerline
at the top of the motor and below the motor's centerline to the right.
In addition to the top location, the manufacturer may also locate the terminal box on
the left side upon user request.
Note. Provision should be made to ensure that cables can enter the terminal box from
any of the four mutually perpendicular directions.
6.2 Motors without foot
The terminal box location is not specified.
7 Mounting dimensions and tolerances
7.1 Overview
Tables 7 ~ 10 in Chapter 11 provide the corresponding relationships between shaft
extension, flange number, foot size, output power and frame number.
7.2 Foot-mounted motors
A, B, C, K shall be selected from Table 1.
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 22 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 1182-2018Geometrical product specifications (GPS) -- Geometrical tolerancing -- Tolerances of form, orientation, location and run-out
- GB/T 1804-2000General tolerances - Tolerances for linear and angular dimensions without individual tolerance indications
ISO 128 · ISO 273 · GB/T 5277-1985 · ISO 273.1979 · ISO 286 · GB/T 1800 · ISO 1101 · ISO 1101.2017 · ISO 2768
Cited by
- GB/T 25302-2025Specification for high efficiency three-phase induction motor for textile purpose (frame sizes 90 to 225)
- GB/T 21974-2024YZRW series eddy-current braking wound-rotor three-phase induction motors for crane and metallurgical applications - Technical specification (frame size 112315)
- GB/T 30144-2024YZP-H series variable-frequency adjustable-speed three-phase induction motors for crane in ships - Technical specification (frame size 112 to 400)
- GB/T 12974.1-2023General specification for a.c. lift motor - Part 1: Three-phase asynchronous motor
- GB/T 12974.2-2023General specification for a.c. lift motor - Part 2: Permanent magnet synchronous motor
- GB/T 15548-2023General specification for three-phase synchronous generators driven by reciprocating internal combustion engine
How to Download GB/T 4772.1-2025
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 1182-2018 — Geometrical product specifications (GPS) -- Geometrical tolerancing -- Tolerances of form, orientation, location and run-out
GB/T 1800.1-2020 — Geometrical product specifications (GPS) - ISO code system for tolerances on linear sizes - Part 1: Basis of tolerances, deviations and fits
GB/T 1800.2-2020 — Geometrical product specifications (GPS) - ISO code system for tolerances on linear sizes - Part 2: Tables of standard tolerance classes and limit deviations for holes and shafts
Secure payment via Stripe
Payments accepted
GB/T 4772.1-2025
$385.00