GB/T 2794-2022Determination for viscosity of adhesives (English PDF)
胶黏剂黏度的测定
Open the GB/T 2794-2022 preview as PDF
This is a limited preview
Buy now to download the full PDF (15 pages)
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
October 12, 2022
Implementation date
May 1, 2023
Scope
GB/T 2794-2022 is the English-translated version of 胶黏剂黏度的测定.
GB/T 2794-2022 covers the measurement of the viscosity of adhesives by single cylinder rotational viscometer, by cone-plate rotational viscometer and by rotational rheometer — the sampling, the apparatus, the conditioning of the sample, the three test methods, the representation of the result, and the test report. Viscosity decides whether an adhesive can be pumped, sprayed, rolled or trowelled at all, and how much of it stays where it was put before it sets, which is why it is the first number a converter checks on a drum that has just arrived. It is also a number that moves: the same adhesive reads one way warm and another way cold, and differently again depending on how fast it is sheared. So the sample is taken in accordance with GB/T 20740 and conditioned in the standard environment of GB/T 2918 before anything is measured, and the instruments are pinned down in their own clause, the single cylinder viscometer to a measurement accuracy of +/-5 %. In that first method a cylindrical or disc-shaped rotor is turned at a constant rate through the sample under test. Written for adhesive manufacturers, for the users who check incoming batches, and for laboratories asked to settle an argument between the two.
Document preview — GB/T 2794-2022
National Standard of the People's Republic of China
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- 1 Scope5
- 2 Normative references5
- 3 Terms and definitions5
- 4 Sampling5
- 5 Apparatus5
- 6 Sample conditioning7
- 7 Test methods7
- 8 Result representation9
- 9 Test report9
Foreword
This document was issued on 12 October 2022 by the State Administration for Market Regulation; Standardization Administration of the PRC and takes effect on 1 May 2023.
It is a GB/T standard: recommended rather than compulsory, but it is the text a Chinese reviewer applies when assessing a submission.
1 Scope
GB/T 2794-2022 covers the measurement of the viscosity of adhesives by single cylinder rotational viscometer, by cone-plate rotational viscometer and by rotational rheometer — the sampling, the apparatus, the conditioning of the sample, the three test methods, the representation of the result, and the test report. Viscosity decides whether an adhesive can be pumped, sprayed, rolled or trowelled at all, and how much of it stays where it was put before it sets, which is why it is the first number a converter checks on a drum that has just arrived. It is also a number that moves: the same adhesive reads one way warm and another way cold, and differently again depending on how fast it is sheared. So the sample is taken in accordance with GB/T 20740 and conditioned in the standard environment of GB/T 2918 before anything is measured, and the instruments are pinned down in their own clause, the single cylinder viscometer to a measurement accuracy of +/-5 %. In that first method a cylindrical or disc-shaped rotor is turned at a constant rate through the sample under test. Written for adhesive manufacturers, for the users who check incoming batches, and for laboratories asked to settle an argument between the two.
This document describes methods for determination for the viscosity of adhesives using
single cylinder rotational viscometer, cone-plate rotational viscometer, and rotational
rheometer.
This document applies to the determination for viscosity of adhesives.
2 Normative references
The contents of the following documents, through normative references in this text,
constitute indispensable provisions of this document. Among them, for dated references,
only the edition corresponding to that date applies to this document. For undated
references, the latest edition (including all amendments) applies to this document.
GB/T 2918 Plastics - Standard atmospheres for conditioning and testing
GB/T 8170 Rules of rounding off for numerical values and expression and
judgement of limiting values
GB/T 20740 Adhesive - Sampling
3 Terms and definitions
This document does not have terms and definitions that need to be defined.
4 Sampling
Sample sampling shall be carried out in accordance with the provisions of GB/T 20740.
5 Apparatus
5.1 Single cylinder rotational viscometer
Measurement accuracy: +/-5%.
5.2 Cone-plate rotational viscometer
Measurement accuracy: +/-5%.
6 Sample conditioning
The samples shall be conditioned and tested in the standard conditioning environment
specified in GB/T 2918.
7 Test methods
7.1 Method 1: Single cylinder rotational viscometer method
7.1.1 Principle
A cylindrical or disc-shaped rotor rotates at a constant rate through the sample to be
tested. Measure the torque caused by the viscous drag; combine with the selected speed
and rotor type; obtain the viscosity value of the sample.
7.1.2 Test procedure
7.1.2.1 Add an appropriate amount of the sample to be tested into the sample holder as
needed, to ensure that no air bubbles are introduced. If necessary, use vacuum or other
suitable methods to eliminate air bubbles. If the sample is volatile or hygroscopic,
during the constant-temperature process, it shall seal the sample holder.
7.1.2.2 Select the appropriate rotor and speed, so that the meter reading is within
20%~90% of the maximum range.
7.1.2.3 Make sure that the sample temperature reaches the specified temperature.
Unless otherwise specified, the temperature of the test sample shall be kept at
(23.0+/-0.5)°C. When conducting arbitration, the thermometer shall be immersed in the
sample, to test the actual temperature of the sample.
7.1.2.4 Start the motor; the rotor rotates in the test sample. After the reading is stable,
record the data. When measuring the viscosity of some adhesives, if the reading
displayed by the instrument is unstable, the viscosity value should be read at a specified
time, such as 15 min. The time can also be determined through negotiation between the
two parties.
7.1.2.5 After each test, remove the rotor from the instrument. Use a solvent, which can
completely dissolve the sample, to carefully clean the rotor and cylinder.
7.1.2.6 Take two samples for parallel test, until the difference between the readings of
two consecutive sample tests is less than 3%. The result is the average of two
measurements.
7.2 Method 2: Cone-plate rotational viscometer method
7.2.1 Principle
Place the sample to be tested between the rotor and the plate. When the rotor rotates,
measure the torque caused by the viscous drag; combine with related parameters such
as the selected rotational speed and the diameter and angle of the rotor; obtain the
viscosity value of the sample.
7.2.2 Test procedure
7.2.2.1 According to the sample, select the appropriate instrument model, rotor and
speed; so that the instrument reading is within 10%~90% of the maximum range.
7.2.2.2 Make sure the viscometer is at the temperature required for the determination.
7.2.2.3 Zero the instrument.
7.2.2.4 Set the cone-plate gap.
7.2.2.5 According to the viscosity and thixotropy of the adhesive and the requirements
of the rotor, take an appropriate amount of the sample to be tested; place it in the center
of the plate; to ensure that the space between the rotor and the plate is filled with
adhesive. There shall be no excessive adhesive overflow. At the same time, ensure that
no air bubbles are introduced.
7.2.2.6 Wait for a period of time for the sample temperature to reach thermal
equilibrium, to ensure that the sample temperature is within the specified range. Unless
otherwise specified, the temperature of the test sample shall be kept at (23.0+/-0.5)°C.
7.2.2.7 Start the rotor. After the reading is stable, record the data.
7.2.2.8 After each test, use a solvent, which can completely dissolve the sample, to
carefully clean the rotor and plate.
7.2.2.9 Take two samples for parallel test, until the difference between the readings of
two consecutive sample tests is less than 3%. The result is the average of two
measurements.
7.3 Method 3: Rotational rheometer method
7.3.1 Principle
Apply strain (stress) to the rotor to test. According to the shear rate and shear stress,
measure the viscosity of the sample under the corresponding temperature conditions.
7.3.2 Test procedure
......
Remaining clauses in the full document
- 8 Result representation
- 9 Test report
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
GB/T 2918 Plastics - Standard atmospheres for conditioning and testing · GB/T 20740 Adhesive - Sampling
Cited by
Similar standards
GB 38031-2025|GB/T 2794|GB/T 2794-2013|GB/T 2794-1995|GB 2794-1981|GB/T 2918|GB/T 8170|GB/T 20740
How to Buy GB/T 2794-2022
- 1Add to cart. Click the "Buy GB/T 2794-2022" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 47310-2026 — Determination of total silicon, aluminium, iron, potassium, sodium, calcium, magnesium, manganese, phosphorus, titanium and sulfur in soil - Monochromatic excitation energy dispersive X-ray fluorescence spectrometry
GB/T 47321-2026 — Specification for the warning data exchange of the national emergency early warning dissemination system
GB/T 47293-2026 — Determination of available mercury in soil
Secure payment via Stripe
Payments accepted
GB/T 2794-2022
$95.00