GB/T 1094.1-2013Power transformers-Part 1: General (English PDF)
电力变压器 第1部分:总则
Also coversGBT1094.1-2013
This is a limited preview
Buy now to download the full PDF
Need quotation for your management?
Get a formal quotation for GB/T 1094.1-2013 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China
Level / Type
National · Recommended
Issue date
December 17, 2013
Implementation date
December 14, 2014
Scope
GB/T 1094.1-2013 is the English-translated version of 电力变压器 第1部分:总则.
GB/T 1094.1-2013 — This part of GB 1094 applies to three-phase and single-phase power transformers (including auto-transformers) with the exception of certain categories of small and special transformers such as.
Found what you need?
Document preview — GB/T 1094.1-2013
National Standard of the People's Republic of China
- ICS
- 29.180
- Classification
- K41
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China
Contents
- Foreword...3
- 1 Scope...6
- 2 Normative references...7
- 3 Terms and definitions...8
- 4 Service conditions...26
- 5 Rating and general requirements...29
- 6 Requirements for transformers having a tapped winding...36
- 7 Connection and connection symbol...44
- 8 Rating plates...50
- 9 Safety, environmental and other requirements...53
- 10 Tolerances...55
- 11 Tests...57
- 12 Electromagnetic compatibility (EMC)...69
- 13 High frequency switching transients...69
Foreword
Clause 2, Clause 3, 11.2 ~ 11.12, Clause 12, Clause 13, Annex A ~ Annex F, Annex
H, and Annex I of this Part are recommended, and the rest are mandatory.
GB 1094 Power transformers currently includes the following parts.
-- Part 1.General;
-- Part 2.Temperature rise for liquid-immersed transformers;
-- Part 3.Insulation levels, dielectric tests and external clearances in air;
-- Part 4.Guide to the lightning impulse and switching impulse testing - Power
transformers and reactors;
-- Part 5.Ability to withstand short circuit;
-- Part 6.Reactors;
-- Part 7.Loading guide for oil-immersed power transformers;
-- Part 10.Determination of sound levels;
-- Part 10.1.Determination of sound levels - Application guide;
-- Part 11.Dry-type transformers;
-- Part 12.Loading guide for dry-type power transformers;
-- Part 14.Liquid-immersed power transformer using high-temperature insulation
materials;
-- Part 16.Transformers for wind turbine applications.
This Part is Part 1 of GB 1094.
This Part is drafted in accordance with the rules given in GB/T 1.1-2009.
This Part replaces GB 1094.1-1996, Power transformers - Part 1.General. Compared
with GB 1094.1-1996, the main technical changes are as follows.
-- Add the definition of harmonic content;
-- Add a subclause on transport;
-- Add functional method of specification;
-- Add connection symbols for single phase transformers;
-- Add safety and environmental requirements;
-- Add requirements for liquid preservation systems;
-- Add a clause on DC currents in neutral circuits;
-- Adjust the test items;
-- Add contents such as leak testing with pressure for liquid-immersed type
transformers (tightness test), vacuum deflection test for liquid immersed
transformers, pressure deflection test for liquid-immersed type transformers, and
vacuum tightness test on site for liquid-immersed type transformers;
-- Add informative annexes on facilities for condition monitoring to transformers
and environmental and safety considerations.
This Part uses the re-drafting method to modify IEC 60076-1.2011 Power transformers
- Part 1.General.
There are technical differences between this Part and IEC 60076-1.2011.The terms
which are involved in these differences have been marked by vertical single lines (|) on
the outer page margins; Annex A gives a list of corresponding technical differences and
their causes.
This Part also makes the following editorial changes.
-- Change "Ei" and "Ii" in the key of 3.13.3 in IEC 60076-2011 to "E2i" and "I2i"
respectively;
-- Combine Figure 1a), Figure 1b) and Figure 1c) in IEC 60076-1.2011 into one
figure;
-- Remove the content of "Note" of 7.1.2 in IEC 60076-1.2011;
-- Make the example under 7.2.4 in IEC 60076-1.2011 the content of 7.2.5;
-- Adjust the layout of Table 1 in IEC 60076-1.2011;
-- Modify the tap-position in Table B.2 and Table B.3 in IEC 60076-1.2011;
-- Add the informative Annex A, where the technical differences between this Part
and IEC 60076-1.2011 and the causes are listed;
-- Add the informative Annex B, where the contents – vacuum deflection test for
liquid immersed transformers and pressure deflection test for liquid-immersed
type transformers – not adopted from IEC 60076-1.2011, are listed;
-- Modify Annex A, Annex B, Annex C, Annex D, Annex E, Annex F and Annex G
in IEC 60076-1.2011 to Annex D, Annex E, Annex F, Annex C, Annex G, Annex
H and Annex I.
1 Scope
This part of GB 1094 applies to three-phase and single-phase power transformers
(including auto-transformers) with the exception of certain categories of small and
special transformers such as.
2 Normative references
The following referenced documents are indispensable for the application of this
document. For dated references, only the edition cited applies. For undated references,
the latest edition of the referenced document (including any amendments) applies.
GB 1094.2, Power transformers - Part 2.Temperature rise for liquid-immersed
transformers (GB 1094.2-2013, IEC 60076-2.2011, MOD)
3 Terms and definitions
Terms and definitions determined by GB/T 2900.15, and the following, are applicable
to this document. For ease of use, some of the terms and definitions in GB/T 2900.15
are repeated below, and certain terms and definitions are modified.
4 Service conditions
This Part gives detailed requirements for transformers for use under the following
conditions.
For transformers intended to be installed indoors, some of these environmental
conditions may not be applicable.
5 Rating and general requirements
A two-winding transformer has only one value of rated power, identical for both
windings.
The user shall specify the cooling medium (air or water).
If the user has particular requirements for the cooling method(s) or cooling equipment,
this shall be stated in the enquiry.
6 Requirements for transformers having a tapped winding
This type of specification is intended to allow the purchaser to specify operational
requirements and not the category of voltage variation or which winding is to be tapped.
This method of specification is not applicable to separate-winding transformers up to
and including 2 500 kVA with a tapping range not exceeding ±5%.
7 Connection and connection symbol
The existence of a stabilizing or a test winding (a delta or star-connected winding which
is not terminated for external three-phase loading) is indicated, after the symbols of
loadable windings, with the symbol "+d" or "+y" according to its connection as in the
examples below.
8 Rating plates
The information listed below shall be included on the rating plate when it is applicable
to a particular transformer.
9 Safety, environmental and other requirements
The manufacturer shall consider the safety of operators and maintenance staff in the
design of the transformer in particular the following aspects.
The centre of gravity of the transformer in the transport configuration shall be
permanently marked on at least two adjacent sides of the transformer for transformers
with a transport mass in excess of 5 tons.
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.
Referenced standards
Normative references
GB 1094.2 · GB 1094.2-2013 · IEC 60076
Cited by
- GB/T 31487.2-2025Direct current deicers - Part 2: Converters
- GB 20052-2024Minimum allowable values of energy efficiency and energy efficiency grades for power transformers
- GB/T 32825-2024Technical parameters and requirements for three-phase dry-type tridimensional wound core power transformers
- GB/T 5169.49-2024Fire hazard testing for electric and electronic products - Part 49: Arc ignition test method for materials
- GB/T 10228-2023Technical parameters and requirements for dry-type power transformers
- GB/T 25120-2023Railway applications - Traction transformers and inductors on board rolling stock
How to Download GB/T 1094.1-2013
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 1094.10-2022 — Power transformers - Part 10: Determination of sound levels
GB/T 1094.11-2022 — Power transformers—Part 11: Dry-type transformers
GB/T 1094.14-2022 — Power transformer - Part 14: Liquid-immersed power transformer using high-temperature insulation materials
Secure payment via Stripe
Payments accepted
GB/T 1094.1-2013
$790.00