Scope
GB/T 24844-2018 is the English-translated version of 1000kV交流系统用油浸式并联电抗器技术规范.
GB/T 24844-2018 is the Chinese technical specification for the oil-immersed shunt reactors used in 1000 kV AC systems. It applies to single-phase units rated at 1000 kV with a rated capacity from 160 Mvar to 320 Mvar, and products of other capacities may follow it except for the basic parameters.
It covers the normal conditions of use, the performance parameters, including the insulation level of the neutral point, the technical requirements, the tests, and marking, packaging and transport.
A normative annex deals with the neutral grounding reactor used with these shunt reactors, including its insulation level, rated short-circuit currents and tests.
Reactor manufacturers, test laboratories and grid operators use it. It replaces GB/Z 24844-2009, was issued on 13 July 2018 and has applied since 1 February 2019.
Found what you need?
Document preview — GB/T 24844-2018
National Standard of the People's Republic of China
- ICS
- 29.180
- Classification
- K 41
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 Conditions of use
- 5 performance parameters
- 6 Technical requirements
- 7 test
- 8 signs, packaging, transportation
- Appendix A (Normative Appendix) Neutral Grounding Reactor for 1000kV AC Oil-immersed Shunt Reactor
- Reference
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard replaces GB /Z 24844-2009 "Technical Specifications for Oil-immersed Shunt Reactors for 1000kV AC Systems", and Compared with GB /Z 24844-2009, the main technical changes are as follows.
--- Updated normative references, deleted expired and unquoted standards (see Chapter 2, 2009, 2nd) chapter);
--- Added basic parameters of 160Mvar/1000kV and 280Mvar/1000kV shunt reactors (see 5.1);
--- Supplemented the relevant parameters of the neutral point insulation level of 1000kV shunt reactor (see 5.2);
--- Removed the pressure release value of the 1000kV shunt reactor pressure release device (see 6.6.2 of the 2009 edition);
--- Modified 1000kV shunt reactor test project. type test added "end lightning interception impact test"; radio dry The disturbance test is listed as a special test item; the "1.1 times overcurrent test" is changed to "1.05 times overcurrent test; the neutral point is deleted." "Discharge measurement", the "end external pressure test" is modified to "end external pressure test (with partial discharge monitoring)", the neutral point Partial discharge measurements are combined with neutral point external pressure test (see Chapter 7, Chapter 7 of the 2009 edition);
--- Revised the requirement for dry gas before oil tanking, and the dew point was changed from "not higher than -40 °C" to "not higher than -50 ° C" (see 8.2.1, 8.2.2 of the 2009 edition);
--- Removed the requirement for gas purity of gas-filled transport (see 8.2.2 of 2009 edition).
--- Supplemented the insulation level at the head end of the neutral grounding reactor (see A.2.2);
--- Revised the rated thermal short-circuit current of the neutral grounding reactor (see A.2.3, 2009 edition of A.2.4);
--- Increased the requirements for the rated mechanical short-circuit current of the neutral grounding reactor (see A.2.4);
--- Added pilot project for neutral grounding reactor (see A.3).
1 Scope
This standard specifies the performance parameters, technical requirements, tests, signs, packaging and performance of oil-immersed shunt reactors for 1000kV AC systems. Transportation and other requirements.
This standard applies to single-phase oil-immersed shunt reactors with a voltage rating of 1000kV and a rated capacity of 160Mvar~320Mvar. product. In addition to the basic parameters of the product, the technical requirements of other capacity products can be implemented with reference to this standard.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this document. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 1094.1 Power transformers - Part 1. General
GB/T 1094.2 Power transformers - Part 2. Temperature rises of liquid immersed transformers
GB/T 1094.3 Power transformers - Part 3. Insulation level, insulation test and external insulation air gap
GB/T 1094.6 Power transformers - Part 6. Reactors
GB/T 1094.10 Power transformers - Part 10. Sound level determination
GB 2536 Unused mineral insulating oil for electrical fluid transformers and switches
GB/T 2900.95 Electrotechnical terminology transformers, voltage regulators and reactors
GB/T 5273 high voltage electrical terminal size standardization
DL/T 1094 Guidelines for Selection of Insulating Oil for Power Transformers
JB/T 501 Power Transformer Test Guide
3 Terms and definitions
The terms and definitions defined in GB/T 2900.95 and GB/T 1094.6 apply to this document.
4 Conditions of use
4.1 Normal use conditions
4.1.1 Environmental conditions
The environmental conditions are as follows.
a) The altitude does not exceed 1000m.
b) Ambient temperature.
1) Maximum temperature. 40 ° C;
2) The hottest month average temperature. 30 ° C;
3) The highest annual average temperature. 20 ° C; […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 1094.1Power transformers-Part 1: General
- GB/T 1094.3Power transformers -- Part 3: Insulation levels, dielectric tests and external clearances in air
- GB/T 1094.6Power transformers -- Part 6: Reactors
- GB/T 1094.10Power transformers - Part 10: Determination of sound levels
- GB 2536Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear
- GB/T 2900.95Electrotechnical terminology -- Transformers, voltage regulators and reactors
GB/T 1094.2
Similar standards
How to Download GB/T 24844-2018
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
DL/T 1094-2018 — Guide to the choice of power transformer insulating oil
GB 2536-1990 — Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear
GB 2536-2025 — Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear
Secure payment via Stripe
Payments accepted
GB/T 24844-2018
$235.00