GB/T 23753-2020Technical parameters and requirements for 110 kV and above oil-immersed shunt reactors (English PDF)
110kV及以上油浸式并联电抗器技术参数和要求
This is a limited preview
Buy now to download the full PDF (46 pages)
Need quotation for your management?
Get a formal quotation for GB/T 23753-2020 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
November 19, 2020
Implementation date
June 1, 2021
Scope
GB/T 23753-2020 is the English-translated version of 110kV及以上油浸式并联电抗器技术参数和要求.
GB/T 23753-2020 is the Chinese standard "Technical parameters and requirements for 110 kV and above oil-immersed shunt reactors". Its scope clause reads: This standard specifies the terms and definitions of oil-immersed shunt reactors (hereinafter referred to as reactors) with a nominal voltage of 110kV and above.
Definition, use conditions, performance parameters, technical requirements, design and structure, inspection rules and methods, marking, lifting, packaging, transportation and storage.
Unify The performance parameters, technical requirements, design and structure of neutral point grounding reactors for 110kV and above oil-immersed shunt reactors have been determined.
Inspection rules and methods, marking, lifting, packaging, transportation and storage. This standard applies to single-phase and three-phase oil-immersed shunt reactors with a rated frequency of 50 Hz and a system nominal voltage of 110 kV and above The neutral grounding reactor is matched with 110kV and above oil-immersed shunt reactor.
For reactors with special requirements, such as capacitor-adjusting reactors, if the rated impedance has a ±5% or ±10% tap, it is opened through a non-excitation tap To realize the adjustment of reactor capacity, its technical requirements can be used as reference. Its clauses include terms and definitions.
Found what you need?
Document preview — GB/T 23753-2020
National Standard of the People's Republic of China
- ICS
- 29.180
- Classification
- K 41
- Replacing
- GB/T 23753-2009
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Preface
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Conditions of use
- 5 110kV class reactor
- 6 220kV class reactor
- 7 330kV class reactor
- 8 500kV class reactor
- 9 750kV class reactor
- 10 1000kV class reactor
- 11 Marking, lifting, packaging, transportation and storage
1 Scope
This standard specifies the terms and definitions of oil-immersed shunt reactors (hereinafter referred to as reactors) with a nominal voltage of 110kV and above.
Definition, use conditions, performance parameters, technical requirements, design and structure, inspection rules and methods, marking, lifting, packaging, transportation and storage. Unify
The performance parameters, technical requirements, design and structure of neutral point grounding reactors for 110kV and above oil-immersed shunt reactors have been determined.
Inspection rules and methods, marking, lifting, packaging, transportation and storage.
This standard applies to single-phase and three-phase oil-immersed shunt reactors with a rated frequency of 50 Hz and a system nominal voltage of 110 kV and above
The neutral grounding reactor is matched with 110kV and above oil-immersed shunt reactor.
For reactors with special requirements, such as capacitor-adjusting reactors, if the rated impedance has a ±5% or ±10% tap, it is opened through a non-excitation tap
To realize the adjustment of reactor capacity, its technical requirements can be used as reference.
2 Normative references
The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this article
Pieces. For undated references, the latest version (including all amendments) applies to this document.
GB/T 1094.1 Power Transformer Part 1.General Rules
GB/T 1094.2 Power Transformer Part 2.Temperature Rise of Liquid-immersed Transformer
GB/T 1094.3 Power Transformer Part 3.Insulation Level, Insulation Test and External Insulation Air Gap
GB/T 1094.6 Power Transformer Part 6.Reactor
GB/T 1094.10 Power Transformer Part 10.Sound Level Measurement
GB 2536 Unused mineral insulating oil for electrical fluid transformers and switches
GB/T 2900.95 Electrotechnical terminology transformer, voltage regulator and reactor
GB/T 4109 Insulating bushing with AC voltage higher than 1000V
GB/T 5273 Standardization of terminal size for high voltage electrical appliances
GB/T 11604 High-voltage electrical equipment radio interference test method
GB/T 20840.2 Transformer Part 2.Supplementary Technical Requirements for Current Transformers
GB/T 26218.2 Selection and size determination of high-voltage insulators used under dirty conditions Part 2.Porcelain and glass for AC systems
Glass insulator
DL/T 722 Dissolved gas analysis and judgment guidelines in transformer oil
3 Terms and definitions
The terms and definitions defined in GB/T 1094.6 and GB/T 2900.95 apply to this document.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 46 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 1094.1Power transformers-Part 1: General
- GB/T 1094.3Power transformers -- Part 3: Insulation levels, dielectric tests and external clearances in air
- GB/T 1094.6Power transformers -- Part 6: Reactors
- GB/T 1094.10Power transformers - Part 10: Determination of sound levels
- GB 2536Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear
- GB/T 2900.95Electrotechnical terminology -- Transformers, voltage regulators and reactors
GB/T 1094.2 · GB/T 20840.2
Similar standards
Editions of GB/T 23753
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 23753-2020 | Technical parameters and requirements for 110 kV and above oil-immersed shunt reactors | current edition | Current |
| GB/T 23753-2009 | Technical parameters and requirements for 110 kV and above oil-immersed shunt reactors | previous edition | Superseded |
This page sells the current edition, GB/T 23753-2020. Earlier editions are listed for reference only.
How to Download GB/T 23753-2020
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
DL/T 722-2014 — Guide to the analysis and the diagnosis of gases dissolved in transformer oil
GB 2536-1990 — Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear
GB 2536-2025 — Fluids for electrotechnical applications - Unused mineral insulating oils for transformers and switchgear
Secure payment via Stripe
Payments accepted
GB/T 23753-2020