GB/T 11604-2015Testing procedure of radio interference generated by high voltage equipment (English PDF)
This is a limited preview
Buy now to download the full PDF (17 pages)
Need quotation for your management?
Get a formal quotation for GB/T 11604-2015 in 30 minutes.
Issued by
Standardization Administration of China
Level / Type
National · Recommended
Issue date
September 11, 2015
Implementation date
April 1, 2016
Scope
GB/T 11604-2015 (Testing procedure of radio interference generated by high voltage equipment) is available as an English-translated PDF.
GB/T 11604-2015 — This standard specifies the high-voltage electrical equipment radio interference testing methods.
This standard applies in the laboratory of AC and DC high voltage electrical equipment (including attachments) radio interference test, the device comprising. a high pressure Switchgear, transformers, voltage divider, coupling capacitors, surge arresters, bushings, insulators and the like.
This standard specifies the test methods are applicable to type tests, routine tests, sampling tests and performance tests. The standard test method is limited to measuring the test circuit conductive portion of the test radio interference regulations, which do not involve radiation section Interference.
Found what you need?
Document preview — GB/T 11604-2015
National Standard of the People's Republic of China
- ICS
- 19.080
- Classification
- K 40
- Replacing
- GB/T 11604-1989
Issued by: Standardization Administration of China
Contents
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Test Conditions
- 4.1 General principles
- 4.2 Test state
- 4.3 Pairs of claim 2 test area
- 4.4 Atmospheric conditions
- 4.5 Test Frequency
- 4.6 Measuring Instruments
- Radio interference 5 AC electrical test equipment
- 5.1 AC radio interference test principle
- 5.2 Test circuit and physical layout
- 5.3 Test circuit element
- 5.4 Measuring instrument is connected to receive
- 5.5 Validation checking test circuit
- 5.6 Calibration test circuit
- Determining the level of radio interference 5.7
- 5.8 Additional monitoring during the test
- Radio interference 5.9 AC electrical equipment testing procedures
Foreword
This standard was drafted in accordance with GB/T 1.1-2009 given rules.
This standard replaces GB/T 11604-1989 "high-voltage electrical equipment radio interference testing methods." This standard and GB/T 11604-Compared to 1989, in addition to editorial changes outside the main technical changes are as follows.
--- Radio interference voltage increases, the term describes the rated voltage;
--- Chapter reprogramming, and the techniques and the experimental loop have clearly described in more detail;
--- State of the sample gives a clear definition of description (see 4.2);
--- Test area gives specific requirements (see 4.3);
--- On the atmospheric conditions of temperature, pressure and humidity range be revised, given the high altitude of the altitude correction requirements (see 4.4);
--- The reference test frequency recommended values \u200b\u200bgiven in our laboratory 1MHz (see 4.5);
--- Increased content measuring instruments (see 4.6);
--- Radio interference AC electrical test equipment in the circuit layout, installation and test validation checking arrangement, loop, loop calibrator, Additional monitoring period and so give a detailed description (see Chapter 5);
--- Increasing the DC electrical equipment radio interference test content (see Chapter 6);
--- Increase A "standard CISPR quasi-peak measuring instrument for receiving AC corona noise response" Appendix informative;
--- Increase the informative Appendix B "differs from the basic standard instrument CISPR radio interference measuring apparatus";
--- Increase the informative appendix C "DC radio interference phenomenon described." this standard uses the redrafted law revision using IEC/T RCISPR18-2.2010 Radio interference "of overhead lines and high-voltage equipment Characteristics - Part 2. Measurement methods and procedures to determine the limits. " The Standard and IEC/T RCISPR18-2.2010 and technical differences the following reasons.
--- Reference of this standard IEC/T RCISPR18-2. Section 20104.5 "radio interference measuring laboratory of high voltage equipment" content Modify other sections not involved;
--- Radio interference voltage increases, the term describes the rated voltage;
--- On the atmospheric conditions of temperature, pressure and humidity range be revised, given the high altitude of the altitude correction requirements (see 4.4);
--- The reference test frequency recommended values \u200b\u200bgiven in our laboratory 1MHz (see 4.5);
--- Increasing the DC electrical equipment radio interference test content (see Chapter 6).
Please note that some of the content of this document may involve patents. Release mechanism of the present document does not assume responsibility for the identification of these patents.
The standard proposed by China Electrical Equipment Industrial Association.
This standard by the national high voltage test and insulation technology with Standardization Technical Committee (SAC/TC163).
This standard was drafted. Xi'an High Voltage Apparatus Research Institute Co., Ltd., China Electric Power Research Institute, the national high-voltage electrical quality monitoring Governor Inspection Center, the National Insulator arrester Quality Supervision and Inspection Center, Kunming Electric Apparatus Research Institute, the National Quality Supervision, Inspection Transformer Heart, high-voltage electrical machinery industry product quality inspection center (Shenyang), Tsinghua University, Xi'an Jiaotong University, Xi'an Electric Power System Co.
Division, Xi'an high-voltage electrical stock company, Xi'an Electric Transformer Co., Ltd., Xi'an Electric arrester Co., Ltd., New Northeast Electric (Shenyang) High Voltage Switchgear Co., Ltd. Henan high level of electrical, Guilin Power Capacitor Co., Ltd., Shaanxi Power Academy of Sciences, Hubei Electric Power Research Institute, Electric Power Research Institute of Jiangxi Province, Guangdong Electric Power Design Institute, China Southern Power Grid Technology Research Research Centre, Siemens (China) Co., Ltd. Shanghai Branch.
1 Scope
This standard specifies the high-voltage electrical equipment radio interference testing methods.
This standard applies in the laboratory of AC and DC high voltage electrical equipment (including attachments) radio interference test, the device comprising. a high pressure Switchgear, transformers, voltage divider, coupling capacitors, surge arresters, bushings, insulators and the like.
This standard specifies the test methods are applicable to type tests, routine tests, sampling tests and performance tests.
The standard test method is limited to measuring the test circuit conductive portion of the test radio interference regulations, which do not involve radiation section Interference.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document.
GB 311.1-2012 insulation coordination - Part 1. Definitions, principles and rules (IEC 60071-1:2006, MOD) GB/T 2900.19-1994 Electrotechnical term high voltage test technique and insulation coordination (neqIEC 60071-1.1993) GB/T 4365-2003 Electrotechnical terminology Electromagnetic Compatibility (idt IEC 60050 (161) 1990) GB/T 6113.101 radio disturbance and immunity measuring apparatus and methods - Part 1-1. Radio disturbance and anti-Interference measuring equipment measuring equipment (GB/T 6113.101-2008, CISPR16-1-1.2006, IDT) GB/T 16927.1 High-voltage test techniques - Part 1. General definitions and test requirements (GB/T 16927.1-2011, IEC 60060-1:2010, MOD) CISPR16-1-2 radio disturbance and immunity measuring apparatus and method - Part 1-2. Radio disturbance and immunity measuring Instrument auxiliary equipment conducting interference (Specificationforradiodisturbanceandimmunitymeasuringapparatusand methods-Part 1-2. Radiodisturbanceandimmunitymeasuringapparatus-Ancilaryequipment-Conducteddisturbances)
3 Terms and Definitions
GB/T 4365-2003 and defined the following terms and definitions apply to this document.
Radio interference (high voltage electrical equipment) radiointerference (ofhighvoltageequipment) Under normal operation of electrical equipment having a radio frequency voltage generated by the electromagnetic interference components.
Note. This standard is a direct measurement device radio interference pulse current through an electrical circuit coupling loops, and radio interference voltage to represent radio the level of interference. Radio interference voltage in units of µV, can also be expressed in decibels, at this time, 1µV to 0dB.
AC electrical equipment the maximum voltage highestvoltageforalternatingcurrentequipment Um Valid values \u200b\u200baccording to equipment insulation and other features associated equipment standards associated design phase maximum voltage. In normal Under operating conditions by the relevant provisions of the Technical Committee, the voltage can be continuously applied to the device.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.
Referenced standards
Normative references
- GB 311.1-2012Insulation co-ordination -- Part 1: Definitions, principles and rules
- GB/T 2900.19-1994Electrotechnical terminology - High-voltage test technique and insulation co-ordination
- GB/T 4365-2003Electrotechnical terminology -- Electromagnetic compatibility
- GB/T 6113.101Specification for radio disturbance and immunity measuring apparatus and methods—Part 1-1: Radio disturbance and immunity measuring apparatus—Measuring apparatus
- GB/T 6113.101-2008Specification for radio disturbance and immunity measuring apparatus and methods—Part 1-1: Radio disturbance and immunity measuring apparatus—Measuring apparatus
- GB/T 16927.1High-voltage test techniques -- Part 1: General definitions and test requirements
IEC 60071 · IEC 60050 · IEC 60060
Cited by
- GB/T 32520-2024Metal-oxide surge arresters with external series gap (EGLA) for overhead transmission and distribution lines of a. c. systems above 1 kV
- GB/T 30547-2023Filter resistor for high voltage direct current (HVDC) transmission system
- GB/T 11032-2020Metal-oxide surge arresters without gaps for a. c. systems
- GB/T 23753-2020Technical parameters and requirements for 110 kV and above oil-immersed shunt reactors
- GB/T 22071.2-2017Test guide for instrument transformers - Part 2: Inductive voltage transformers
- NB/T 42019-2013Specification and Technical Requirements for 750kV and 1000kV Oil-immersed Shunt Reactors
How to Download GB/T 11604-2015
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 311.1-2012 — Insulation co-ordination -- Part 1: Definitions, principles and rules
GB/T 16927.1-2011 — High-voltage test techniques -- Part 1: General definitions and test requirements
GB/T 4365-2003 — Electrotechnical terminology -- Electromagnetic compatibility