Valid

GB/T 37008-2018Technical specification of reactors for VSC-HVDC applications (English PDF)

柔性直流输电用电抗器技术规范

Preview PDF

This is a limited preview

Buy now to download the full PDF (17 pages)

Need quotation for your management?

Get a formal quotation for GB/T 37008-2018 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

December 28, 2018

Implementation date

July 1, 2019

Scope

GB/T 37008-2018 is the English-translated version of 柔性直流输电用电抗器技术规范.

GB/T 37008-2018 is the technical specification for the reactors used in flexible DC (VSC-HVDC) transmission. It covers dry-type air-core bridge arm reactors connected to modular multilevel voltage source converters, in both symmetrical monopole and bipolar systems.

The document sets out terms, symbols and the product model designation, the conditions of use, and the technical requirements, including the temperature rise limits for the windings, metal structures and terminals.

It then lists the routine, type and special tests with their test methods, and closes with the nameplate and with lifting, marking, packaging, transport and storage.

It builds on the GB/T 1094 series for power transformers and reactors and on GB/T 25092-2010. It was issued on 28 December 2018 and has applied since 1 July 2019.

Found what you need?

Document preview — GB/T 37008-2018

National Standard of the People's Republic of China

ICS
29.180
Classification
K 41

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions
  • 4 symbol
  • 5 product model
  • 6 Conditions of use
  • 7 Technical requirements
  • 8 Test items and methods
  • 9 nameplate
  • 10 Lifting, marking, packaging, transport and storage

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009.

1 Scope

This standard specifies the terms and definitions, symbols, product models, operating conditions, technical requirements, and test items of reactors for flexible DC transmission. Objectives, nameplates, lifting, marking, packaging, transportation and storage.

This standard applies to the following products connected to modular multilevel voltage source converters.

--- Dry type hollow bridge arm reactor for symmetrical monopole flexible direct current transmission;

--- Dry-type hollow bridge arm reactor for bipolar flexible DC transmission ("dry hollow bridge arm reactor" hereinafter referred to as "bridge arm reactor").

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this document. For undated references, the latest edition (including all amendments) applies to this document.

GB/T 311.1 Insulation coordination Part 1: Definitions, principles and rules

GB/T 1094.1 Power transformers - Part 1: General

GB/T 1094.2 Power transformers - Part 2: Temperature rises of liquid immersed transformers

GB/T 1094.3-2017 Power transformers - Part 3: Insulation level, insulation test and external insulation air gap

GB/T 1094.6 Power transformers - Part 6: Reactors

GB/T 1094.11 Power transformers - Part 11: Dry transformers

GB/T 22079 General definitions, test methods and connections for indoor and outdoor polymer insulators with nominal voltages above 1000V Collection criteria

GB/T 25092-2010 Dry type hollow wave reactor for HVDC transmission

GB/T 37011 Specification for Transformers for Flexible DC Transmission

DL/T 1472.1 Pillar insulators for DC fields of converter stations - Part 1

JB/T 3837 Transformer product model preparation method

3 Terms and definitions

GB/T 1094.6, GB/T 1094.11, GB/T 25092-2010 and GB/T 37011 as defined in the following terms and definitions Applicable to this document.

3.1 Bridge arm reactor

A reactor connected in series on the bridge of the voltage source converter.

Note 1. The current flowing under normal conditions consists of DC bias current, power frequency current and superimposed harmonic current, which mainly suppresses the circulation and suppression between the bridge arms. The effect of the bridge arm fault current rising too fast during a short circuit.

Note 2. In actual engineering projects, the bridge arm reactor may be arranged on the AC side of the inverter or on the DC side of the inverter.

3.2 Rated inductance

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 37008-2018

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
17 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 37008-2018

$295.00